Power system even harmonics and power quality indices

被引:9
|
作者
Liu, Y
Heydt, GT
机构
[1] Arizona State Univ, Engn Res Ctr, Dept Elect Engn, Tempe, AZ 85287 USA
[2] Florida State Univ, Ctr Adv Power Syst, Tallahassee, FL 32306 USA
关键词
even harmonics; harmonics power quality; power distribution systems; power electronics rectifiers;
D O I
10.1080/15325000590909778
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article deals with the even harmonic components (especially second harmonic components) in power system voltages and currents. The power system even harmonic components can be generated from semi-controlled three-phase rectifiers and dc-biased transformers. Those components cause unequal positive and negative peak values, which are called waveform asymmetry. Waveform asymmetries have a harmful impact on the loads sensitive to voltage or current peaks. The usual power quality indices (e.g., total harmonic distortion, telephone inference factor) are well defined for even harmonics. However none of those indices can capture the waveform asymmetry. Total even harmonic distortion (TEHD) is proposed to consider the special effect of even harmonics. A new index, asymmetry factor (AF), is proposed for the waveform asymmetry. The difference between the AF and the crest factor (CF) is clarified. Simulation and laboratory results are reported.
引用
收藏
页码:833 / 844
页数:12
相关论文
共 50 条
  • [41] Optimal siting and sizing of electric taxi charging stations considering transportation and power system requirements
    Clairand, Jean-Michel
    Gonzalez-Rodriguez, Mario
    Kumar, Rajesh
    Vyas, Shashank
    Escriva-Escriva, Guillermo
    ENERGY, 2022, 256
  • [42] Virtual reality training system for maintenance and operation of high-voltage overhead power lines
    Andrés Ayala García
    Israel Galván Bobadilla
    Gustavo Arroyo Figueroa
    Miguel Pérez Ramírez
    Javier Muñoz Román
    Virtual Reality, 2016, 20 : 27 - 40
  • [43] Voltage-regulation performance of a shunt active filter intended for installation on a power distribution system
    Fujita, Hideaki
    Akagi, Hirofumi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (03) : 1046 - 1053
  • [44] A 6.6-kV transformerless shunt hybrid active filter for installation on a power distribution system
    Inzunza, R
    Akagi, H
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 893 - 900
  • [45] Measurement of subharmonics in power voltages
    Barros, J.
    de Apraiz, M.
    Diego, R. I.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1736 - 1740
  • [46] Virtual reality training system for maintenance and operation of high-voltage overhead power lines
    Ayala Garcia, Andres
    Galvan Bobadilla, Israel
    Arroyo Figueroa, Gustavo
    Perez Ramirez, Miguel
    Munoz Roman, Javier
    VIRTUAL REALITY, 2016, 20 (01) : 27 - 40
  • [47] Optimal Capacitor Location and Sizing for Reducing the Power Loss on the Power Distribution Systems due to the Dynamic Load of the Electric Buses Charging System using the Artificial Bee Colony Algorithm
    Boonraksa, Terapong
    Boonraksa, Promphak
    Marungsri, Boonruang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (04) : 1821 - 1831
  • [48] Allocation and sizing of single tuned passive filters in three-phase distribution systems for power quality improvement
    Melo, Igor D.
    Pereira, Jose L. R.
    Variz, Abilio M.
    Ribeiro, Paulo F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 180
  • [49] A Study of Interconnection Methods between a Microgrid and a Distribution System using a Power-Electronics Converter
    Shoji T.
    Tadokoro T.
    Leandro G.C.
    Kikuma T.
    Noda T.
    IEEJ Transactions on Power and Energy, 2024, 144 (02) : 91 - 100
  • [50] A three-phase shunt active power filter for damping of harmonic propagation in power distribution systems
    Rahmani, Salem
    Al-Haddad, Kamal
    Fnaiech, Farhat
    2006 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-7, 2006, : 1760 - +