A Valuable Option in the Management of Female Recurrent Stress Urinary Incontinence: Re-Adjustable Sling (Remeex Sling System)

被引:3
|
作者
Yasa, Cenk [1 ]
Ugurlucan, Funda Gungor [1 ]
Dural, Ozlem [1 ]
Celik, Serdal [1 ]
Yalcin, Onay [1 ]
机构
[1] Istanbul Univ, Sch Med, Dept Obstet & Gynecol, TR-34093 Istanbul, Turkey
关键词
Failure; Re-adjustable; Recurrence; Stress urinary incontinence; Surgical treatment; FREE VAGINAL TAPE; FOLLOW-UP; SURGICAL-TREATMENT; COMPLICATIONS; GUIDELINES; WOMEN;
D O I
10.1159/000444398
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study was conducted to evaluate the effectiveness and safety of adjustable slings in the treatment of recurrent stress urinary incontinence (SUI) after mid-urethral sling (MUS) failure. Materials and Methods: A prospective study was performed among women with recurrent SUI at the Urogynecology Division of Istanbul School of Medicine between February 2010 and March 2015. All women were preoperatively evaluated with detailed urogynecologic evaluations, which included pelvic examination, Q-tip test, pad test, urodynamic studies and a compilation of the Kings Health Questionnaire (KHQ). Postoperative follow-up was performed at 1, 6 and 12 months and annually thereafter. Our primary outcome was objective cure and patient's satisfaction with treatment. Secondary outcomes included perioperative complications and adverse events. Results: Nineteen women were included in the study. The patients' mean age was 55.3 +/- 6.9 years (range 43-66 years). The median follow-up time was 20.7 +/- 14.0 months (range 6-55 months). The overall cure and improvement rates were 84.2 and 10.5%, respectively. In the satisfaction questionnaire, 15 (79%) patients responded that they were very satisfied and 3 (15.7%) were moderately satisfied. Sling tension re-adjustment was needed during follow-up in 1 patient (5.3%), 13 months after the initial surgery. The preoperative mean KHQ score was 545.9 +/- 243.0 and changed to 237.0 +/- 217.5 (p < 0.05). Postoperative complications were slight and easily manageable. Conclusions: Recurrent SUI is a challenging condition in urogynecology. The Regulation Mechanical External (Remeex) system has been found to be effective in the treatment of recurrent SUI after MUS failure with acceptable adverse effects. The Remeex system has the advantage of readjustment as a valuable option in the long-term management of patients. (C) 2016 S. Karger AG, Basel
引用
收藏
页码:224 / 229
页数:6
相关论文
共 50 条
  • [41] Surgeons' views on sling tensioning during surgery for female stress urinary incontinence
    Borazjani, Ali
    Pizarro-Berdichevsky, Javier
    Li, Jianbo
    Goldman, Howard B.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2017, 28 (10) : 1489 - 1495
  • [42] A repeat mid-urethral sling as valuable treatment for persistent or recurrent stress urinary incontinence
    Verbrugghe, Anneleen
    De Ridder, Dirk
    Van der Aa, Frank
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2013, 24 (06) : 999 - 1004
  • [43] Recurrent Stress Urinary Incontinence After Synthetic Midurethral Sling Procedure
    Walsh, Colin A.
    Moore, Kate H.
    OBSTETRICS AND GYNECOLOGY, 2010, 115 (06) : 1296 - 1301
  • [44] Autologous Transobturator Urethral Sling Placement for Female Stress Urinary Incontinence
    Linder, Brian J.
    Elliott, Daniel S.
    JOURNAL OF UROLOGY, 2015, 193 (03) : 991 - 996
  • [45] Surgery Insight: Management of failed sling surgery for female stress urinary incontinence
    Comiter, Craig V.
    NATURE CLINICAL PRACTICE UROLOGY, 2006, 3 (12): : 666 - 674
  • [46] Long-term outcomes of the AjustA® Adjustable Single-Incision Sling for the treatment of stress urinary incontinence
    Naumann, Gert
    Hagemeier, Thomas
    Zachmann, Stefan
    Al-Ani, Aktham
    Albrich, Stefan
    Skala, Christine
    Laterza, Rosa
    Linaberry, Misti
    Koelbl, Heinz
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2013, 24 (02) : 231 - 239
  • [47] Effect of Morbid Obesity on Midurethral Sling Efficacy for the Management of Stress Urinary Incontinence
    Elshatanoufy, Solafa
    Matthews, Alexandra
    Yousif, Mairy
    Jamil, Marcus
    Gutta, Sravanthi
    Gill, Harmanjit
    Galvin, Shelley L.
    Luck, Ali M.
    FEMALE PELVIC MEDICINE AND RECONSTRUCTIVE SURGERY, 2019, 25 (06): : 448 - 452
  • [48] Repeat Retrourethral Transobturator Sling in the Management of Recurrent Postprostatectomy Stress Urinary Incontinence After Failed First Male Sling
    Soljanik, Irina
    Becker, Armin J.
    Stief, Christian G.
    Gozzi, Christian
    Bauer, Ricarda M.
    EUROPEAN UROLOGY, 2010, 58 (05) : 767 - 772
  • [49] Redo midurethral synthetic sling for female stress urinary incontinence
    Alexander Tsivian
    Menahem Neuman
    Evgeny Yulish
    Avraham Shtricker
    Samuel Levin
    Shmuel Cytron
    A. Ami Sidi
    International Urogynecology Journal, 2007, 18 : 23 - 26
  • [50] Redo midurethral synthetic sling for female stress urinary incontinence
    Tsivian, Alexander
    Neuman, Menahem
    Yulish, Evgeny
    Shtricker, Avraham
    Levin, Samuel
    Cytron, Shmuel
    Sidi, A. Ami
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 (01) : 23 - 26