Benchmarking One-Phase Lipid Extractions for Plasma Lipidomics

被引:34
作者
Hoering, Marcus [1 ]
Stieglmeier, Christoph [1 ]
Schnabel, Katja [1 ]
Hallmark, Tucker [2 ]
Ekroos, Kim [3 ]
Burkhardt, Ralph [1 ]
Liebisch, Gerhard [1 ]
机构
[1] Regensburg Univ Hosp, Inst Clin Chem, Lab Med, D-93042 Regensburg, Germany
[2] Avanti Polar Lipids, Alabaster, AL 35007 USA
[3] Lipid Consulting Ltd, Espoo 02230, Finland
关键词
SAMPLE PREPARATION;
D O I
10.1021/acs.analchem.2c02117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A key element of successful lipidomics analysis is a sufficient extraction of lipid molecules typically by two-phase systems such as chloroform-based Bligh and Dyer (B&D). However, numerous metabolomics and lipidomics studies today apply easy to use one-phase extractions. In this work, quantitative flow injection analysis high-resolution mass spectrometry was applied to benchmark the lipid recovery of popular one-phase extraction methods for human plasma samples. The following organic solvents were investigated: methanol (MeOH), ethanol (EtOH), 2-propanol (IPA), 1-butanol (BuOH), acetonitrile (ACN) and the solvent mixtures BuOH/MeOH (3:1) and MeOH/ACN (1:1). The recovery of polar lysophospholipids was sufficient for all tested solvents. However, nonpolar lipid classes such as triglycerides (TG) and cholesteryl esters (CE) revealed extraction efficiencies less than 5% due to precipitation in polar solvents EtOH, MeOH, MeOH/ACN, and ACN. Sample pellets also contained a substantial amount of phospholipids, for example, more than 75% of total phosphatidylcholine and sphingomyelin for ACN. The loss of lipids by precipitation was directly related to the polarity of solvents and lipid classes. Although, lipid recovery increased with the volume of organic solvent, recovery in polar MeOH remains incomplete also for less polar lipid classes such as ceramides. Addition of stable isotope-labeled internal standards prior to lipid extraction could compensate for insufficient lipid recovery for polar lipid classes including lysolipids and phospholipids but not for nonpolar CE and TG. In summary, application of one-phase extractions should be limited to polar lipid classes unless sufficient recovery/solubility of nonpolar lipids has been demonstrated. The presented data reveal that appropriate lipid extraction efficiency is fundamental to achieve accurate lipid quantification.
引用
收藏
页码:12292 / 12296
页数:5
相关论文
共 21 条
[1]   An Efficient Single Phase Method for the Extraction of Plasma Lipids [J].
Alshehry, Zahir H. ;
Barlow, Christopher K. ;
Weir, Jacquelyn M. ;
Zhou, Youping ;
McConville, Malcolm J. ;
Meikle, Peter J. .
METABOLITES, 2015, 5 (02) :389-403
[2]  
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[3]   MS-based lipidomics of human blood plasma: a community-initiated position paper to develop accepted guidelines [J].
Burla, Bo ;
Arita, Makoto ;
Arita, Masanori ;
Bendt, Anne K. ;
Cazenave-Gassiot, Amaury ;
Dennis, Edward A. ;
Ekroos, Kim ;
Han, Xianlin ;
Ikeda, Kazutaka ;
Liebisch, Gerhard ;
Lin, Michelle K. ;
Loh, Tze Ping ;
Meikle, Peter J. ;
Oresic, Matej ;
Quehenberger, Oswald ;
Shevchenko, Andrej ;
Torta, Federico ;
Wakelam, Michael J. O. ;
Wheelock, Craig E. ;
Wenk, Markus R. .
JOURNAL OF LIPID RESEARCH, 2018, 59 (10) :2001-2017
[4]   The Colorectal Cancer Lipidome: Identification of a Robust Tumor-Specific Lipid Species Signature [J].
Ecker, Josef ;
Benedetti, Elisa ;
Kindt, Alida S. D. ;
Hoering, Marcus ;
Perl, Markus ;
Machmueller, Andrea Christel ;
Sichler, Anna ;
Plagge, Johannes ;
Wang, Yuting ;
Zeissig, Sebastian ;
Shevchenko, Andrej ;
Burkhardt, Ralph ;
Krumsiek, Jan ;
Liebisch, Gerhard ;
Janssen, Klaus-Peter .
GASTROENTEROLOGY, 2021, 161 (03) :910-+
[5]  
FOLCH J, 1957, J BIOL CHEM, V226, P497
[6]   One- vs two-phase extraction: re-evaluation of sample preparation procedures for untargeted lipidomics in plasma samples [J].
Gil, Andres ;
Zhang, Wenxuan ;
Wolters, Justina C. ;
Permentier, Hjalmar ;
Boer, Theo ;
Horvatovich, Peter ;
Heiner-Fokkema, M. Rebecca ;
Reijngoud, Dirk-Jan ;
Bischoff, Rainer .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (23) :5859-5870
[7]   Accurate Lipid Quantification of Tissue Homogenates Requires Suitable Sample Concentration, Solvent Composition, and Homogenization Procedure-A Case Study in Murine Liver [J].
Hoering, Marcus ;
Krautbauer, Sabrina ;
Hiltl, Louisa ;
Babl, Verena ;
Sigruener, Alexander ;
Burkhardt, Ralph ;
Liebisch, Gerhard .
METABOLITES, 2021, 11 (06)
[8]   Accurate quantification of lipid species affected by isobaric overlap in Fourier-transform mass spectrometry [J].
Hoering, Marcus ;
Ejsing, Christer S. ;
Krautbauer, Sabrina ;
Ertl, Verena M. ;
Burkhardt, Ralph ;
Liebisch, Gerhard .
JOURNAL OF LIPID RESEARCH, 2021, 62
[9]   Quantification of Cholesterol and Cholesteryl Ester by Direct Flow Injection High-Resolution Fourier Transform Mass Spectrometry Utilizing Species-Specific Response Factors [J].
Hoering, Marcus ;
Ejsing, Christer S. ;
Hermansson, Martin ;
Liebisch, Gerhard .
ANALYTICAL CHEMISTRY, 2019, 91 (05) :3459-3466
[10]   Correction of Isobaric Overlap Resulting from Sodiated Ions in Lipidomics [J].
Hoesring, Marcus ;
Ekroos, Kim ;
Baker, Paul R. S. ;
Connell, Lisa ;
Stadler, Sonja C. ;
Burkhardt, Ralph ;
Liebisch, Gerhard .
ANALYTICAL CHEMISTRY, 2020, 92 (16) :10966-10970