Bloodstream infection related to catheter connections: a prospective trial of two connection systems

被引:37
作者
Esteve, F. [1 ]
Pujol, M. [1 ]
Limon, E. [1 ]
Saballs, M. [1 ]
Argerich, M. J. [1 ]
Verdaguer, R. [1 ]
Manez, R. [1 ]
Ariza, X. [1 ]
Gudiol, F. [1 ]
机构
[1] Hosp Univ Bellvitge, Hosp Llobregat, Intens Care, E-08907 Barcelona, Spain
关键词
catheter-related bloodstream infection; prevention; intensive care unit; critical care;
D O I
10.1016/j.jhin.2007.05.021
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Bloodstream infections (BSIs) related to central venous catheters (CVCs) and arterial catheters (ACs) are an increasing problem in the management of critically ill patients. Our objective was to assess the efficacy of a needle-free valve connection system (SmartSite((R)), Alaris Medical Systems, San Diego, CA, USA) in the prevention of catheter-related bloodstream infection (CR-BSI). Patients admitted to an intensive care unit were prospectively assigned to have a CVC and AC connected with either a needle-free valve connection system (NFVCS) or a three-way stopcock connection (3WSC). The characteristics of the patients were similar in the two groups. Before manipulation, the NFVCS was disinfected with chlorhexidine digtuconate 0.5% alcoholic solution. The 3WSC was not disinfected between use but it was covered with a protection cap. A total of 799 patients requiring the insertion of a multilumen CVC or AC for > 48 h from 1 April 2002 to 31 December 2003 were included. CR-BSI rates were 4.61 per 1000 days of catheter use in the disinfected NFVCS group and 4.11 per 1000 days of catheter use in the 3WSC group (P = 0.59). When CVC-BSIs and AC-BSIs were analysed separately, the rate of CVC-BSI was 4.26 per 1000 days of catheter use in the NFVCS group, compared with 5.27 in the 3WSC group (P = 0.4). The incidence rate of AC-BSI was 5.00 per 1000 days of catheter use in the NFVCS group, compared with 2.83 in the 3WSC group (P = 0.08). The use of NFVCS does not reduce the incidence of catheter-retated bacteraemia. The arterial catheter (AC) is a significant source of infection in critically ill patients. (c) 2007 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 19 条
[1]  
[Anonymous], MORB MORTAL WKLY REP
[2]  
[Anonymous], 1998, HOSP INFECT
[3]   CONSEQUENCES OF INTRAVASCULAR CATHETER SEPSIS [J].
ARNOW, PM ;
QUIMOSING, EM ;
BEACH, M .
CLINICAL INFECTIOUS DISEASES, 1993, 16 (06) :778-784
[4]   The promise of novel technology for the prevention of intravascular device-related bloodstream infection. I. Pathogenesis and short-term devices [J].
Crnich, CJ ;
Maki, DG .
CLINICAL INFECTIOUS DISEASES, 2002, 34 (09) :1232-1242
[5]   Increased resource use associated with catheter-related bloodstream infection in the surgical intensive care unit [J].
Dimick, JB ;
Pelz, RK ;
Consunji, R ;
Swoboda, SM ;
Hendrix, CW ;
Lipsett, PA .
ARCHIVES OF SURGERY, 2001, 136 (02) :229-234
[6]   Increased catheter-related bloodstream infection rates after the introduction of a new mechanical valve intravenous access port [J].
Maragakis, Lisa L. ;
Bradley, Karen L. ;
Song, Xiaoyan ;
Beers, Claire ;
Miller, Marlene R. ;
Cosgrove, Sara E. ;
Perl, Trish M. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (01) :67-70
[7]   Prevention of intravascular catheter-related infections [J].
Mermel, LA .
ANNALS OF INTERNAL MEDICINE, 2000, 132 (05) :391-402
[8]   Is there evidence for recommending needleless closed catheter access systems in guidelines?: A systematic review of randomized controlled trials [J].
Niël-Weise, BS ;
Daha, TJ ;
van den Broek, PJ .
JOURNAL OF HOSPITAL INFECTION, 2006, 62 (04) :406-413
[9]  
Pena C, 1996, MED CLIN-BARCELONA, V106, P441
[10]   NOSOCOMIAL BLOOD-STREAM INFECTION IN CRITICALLY ILL PATIENTS - EXCESS LENGTH OF STAY, EXTRA COSTS, AND ATTRIBUTABLE MORTALITY [J].
PITTET, D ;
TARARA, D ;
WENZEL, RP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 271 (20) :1598-1601