Comparing cardiac output measurements using electrical cardiometry versus phase contrast cardiac magnetic resonance imaging

被引:1
作者
Sumbel, Lydia [1 ]
Nagaraju, Lakshmi [2 ]
Ogbeifun, Henry [1 ]
Agarwal, Arpit [1 ,3 ]
Bhalala, Utpal [4 ,5 ,6 ,7 ]
机构
[1] Childrens Hosp San Antonio, San Antonio, TX USA
[2] UC Davis Childrens Hosp, Sacramento, CA USA
[3] Baylor Coll Med, Houston, TX USA
[4] Driscoll Childrens Hosp, Corpus Christi, TX USA
[5] Texas A&M Univ, College Stn, TX USA
[6] Univ Texas Med Branch, Galveston, TX USA
[7] Texas A&M Univ, Univ Texas Med Branch UTMB, Pediat & Cardiac Intensivist Driscoll Childrens Ho, Res Advisor & Founding Chair Res Taskforce Hlth Sy, 3533 S Almeda St, Corpus Christi, TX 78411 USA
关键词
Cardiac output; Electrical Cardiometry; Magnetic resonance imaging; Children; VELOCIMETRY; HEART; PRECISION; ACCURACY; CHILDREN;
D O I
10.1016/j.ppedcard.2022.101551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is a growing interest in using non-invasive electrical cardiometry (EC) for continuous cardiac output (CO) measurements in neonates and children. There is a lack of sufficient data to validate CO measured by EC with currently accepted noninvasive techniques such as cardiac MRI (CMRI) in children. Objectives: To assess the degree of agreement between CO measured by EC and CMRI in children. We hypothesized that there is a good degree of agreement between CO measured by EC and CMRI in children. Methods: A retrospective chart review was performed to include patients who had noninvasive CO measured using EC (ICON (R)) and CMRI at our children's hospital between Feb 2019 and May 2020. Anthropometric, clinical and CO data were collected and CMRI parameters such as flow measurements in the aorta and pulmonary artery were analyzed. Data was analyzed using a Bland-Altman plot to compare the agreement between the CO obtained by EC vs. CMRI in this cohort of patients. Results: A total of 52 patients with cardiac disease who had data available from CMRI and ICON (R) were included. The median (IQR) age was 174 (99,201) months and male: female ratio was 1.2:1. A total of 34/52 (60 %) patients had congenital heart disease and 22 had history of surgical interventions prior to noninvasive CO measurements. The Bland-Altman analysis for CO values by both EC and CMRI produced a mean bias (SD) of 0.12 (2.73)1/min for ICON (R) and the 95 % limits of agreement were -5.229 to 5.473 1/min. The precision error was only 1.86 %. The Bland- Altman plot for reproducibility for CO values by EC produced a mean bias (SD) of 0.15 (0.41) 1/min with limits of agreement of -0.66 to 0.97 1/min. The percentage error was 2.34 %. Conclusions: In our cohort of cardiac patients, there was a good degree of agreement between noninvasive CO as measured by Electric Cardiometry and Cardiac MRI.
引用
收藏
页数:5
相关论文
共 26 条
  • [1] Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study
    Blohm, Martin Ernst
    Obrecht, Denise
    Hartwich, Jana
    Mueller, Goetz Christoph
    Kersten, Jan Felix
    Weil, Jochen
    Singer, Dominique
    [J]. CRITICAL CARE, 2014, 18 (06):
  • [2] MEASURING STROKE VOLUME: IMPEDANCE CARDIOGRAPHY VS PHASE-CONTRAST MAGNETIC RESONANCE IMAGING
    Borzage, Matthew
    Heidari, Kimia
    Chavez, Thomas
    Seri, Istvan
    Wood, John C.
    Bluml, Stefan
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2017, 26 (05) : 408 - 415
  • [3] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [4] Non-invasive cardiac output measure end in low and very low birth weight infants: a method comparison
    Grollmuss, Oswin
    Gonzalez, Patricia
    [J]. FRONTIERS IN PEDIATRICS, 2014, 2
  • [5] Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography: Investigation of Concordance between the Two Methods for Measurement of the Cardiac Chamber
    Gurdogan, Muhammet
    Ustabasioglu, Fethi Emre
    Kula, Osman
    Korkmaz, Selcuk
    [J]. MEDICINA-LITHUANIA, 2019, 55 (06):
  • [6] Jenkins Kathy J, 2004, Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu, V7, P180, DOI 10.1053/j.pcsu.2004.02.009
  • [7] Accuracy and precision of non-invasive cardiac output monitoring devices in perioperative medicine: a systematic review and meta-analysis
    Joosten, A.
    Desebbe, O.
    Suehiro, K.
    Murphy, L. S. -L.
    Essiet, M.
    Alexander, B.
    Fischer, M. -O.
    Barvais, L.
    Van Obbergh, L.
    Maucort-Boulch, D.
    Cannesson, M.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) : 298 - 310
  • [8] Cardiac Output Assessed by Invasive and Minimally Invasive Techniques
    Lee, Allison J.
    Cohn, Jennifer Hochman
    Ranasinghe, J. Sudharma
    [J]. ANESTHESIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [9] Cardiac Output Measurements Based on the Pulse Wave Transit Time and Thoracic Impedance Exhibit Limited Agreement With Thermodilution Method During Orthotopic Liver Transplantation
    Magliocca, Aurora
    Rezoagli, Emanuele
    Anderson, Thomas Anthony
    Burns, Sara Maria
    Ichinose, Fumito
    Chitilian, Hovig Vatche
    [J]. ANESTHESIA AND ANALGESIA, 2018, 126 (01) : 85 - 92
  • [10] Newer methods of cardiac output monitoring
    Mehta, Yatin
    Arora, Dheeraj
    [J]. WORLD JOURNAL OF CARDIOLOGY, 2014, 6 (09): : 1022 - 1029