Electrical characteristics and discharge properties of hybrid plasma electrolytic oxidation on titanium

被引:33
|
作者
Nabavi, H. Fakhr [1 ]
Aliofkhazraei, M. [1 ]
Rouhaghdam, A. Sabour [1 ]
机构
[1] Tarbiat Modares Univ, Dept Mat Engn, POB 14115-143, Tehran, Iran
关键词
Corrosion; Hybrid coating; Microstructure; Plasma electrolytic oxidation; Titanium; MICRO-ARC OXIDATION; CORROSION-RESISTANCE; ELECTROCHEMICAL-BEHAVIOR; GROWTH-KINETICS; TI6AL4V ALLOY; PASSIVE FILM; AC-IMPEDANCE; SURFACE; COATINGS; MORPHOLOGY;
D O I
10.1016/j.jallcom.2017.09.028
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study double-layered plasma electrolytic oxidation coatings are synthesized by coating in two different electrolytes. The effects of electrical properties of first fabricated layer (in first electrolyte) on morphology and properties of total hybrid coating are investigated. First layers were applied in four different basic electrolytes consisting of sodium phosphate/citrate (PC), sodium phosphate/silicate (PS), sodium phosphate/tungstate (PT), and sodium phosphate/aluminate (PA) solutions and the second layer was synthesized in calcium acetate/sodium dihydrogen phosphate hydrate solution. The top surface and cross sectional morphology, composition and corrosion resistance properties were thoroughly studied by scanning electron microscopy (SEM), X-ray diffraction (XRD), potentiodynamic polarization (PDP), electrochemical impedance spectroscopy (EIS) and Mott-Schottky analysis (M-S) methods. It was found that the morphology of the second layer depends on the morphology of the first layer, in terms of shape and size of the pores. However, XRD analysis revealed that there was no significant difference between the compositions of the oxide layers. Application of the second layer over PS sample reduced corrosion resistance from 163 to 95 K Omega cm(2) while application of the second layer over PT sample led to increase of corrosion resistance from 31 to 126 K Omega cm(2). The constructive or destructive role of two layers was correlated to discharge energy of the second layer which is in turn determined by the required energy for electrical charging of the first layer. The energy of electrical charging of PS and PT samples are 0.04 and 1.17 J, respectively. Therefore, plasma discharges over PS sample have higher energy, compared to PT sample, and as a result, corrosion resistance of barrier layer of PS sample drops. Electrical parameters extracted from M-S tests also verified our theory that donor density and capacitance of the first layer affect discharge behavior and intensity of the second layer. M-S results are also in conformance with evaluated corrosion resistances measured by EIS method. (C) 2017 Elsevier B. V. All rights reserved.
引用
收藏
页码:464 / 475
页数:12
相关论文
共 50 条
  • [21] Initial stages of plasma electrolytic oxidation of titanium
    Teh, TH
    Berkani, A
    Mato, S
    Skeldon, P
    Thompson, GE
    Habazaki, H
    Shimizu, K
    CORROSION SCIENCE, 2003, 45 (12) : 2757 - 2768
  • [22] Fabrication, properties and biological activity of a titanium surface modified with zinc via plasma electrolytic oxidation
    Luo, Rui
    Jiao, Yang
    Zhang, Sujiajun
    Wu, Jieshi
    Wu, Xingling
    Lu, Kaihang
    Zhang, Pengpeng
    Li, Yankun
    Ni, Xiaohui
    Zhao, Quanming
    FRONTIERS IN MATERIALS, 2023, 10
  • [23] Plasma electrolytic oxidation of brass
    Cheng, Yulin
    Zhu, Zhunda
    Zhang, Qinghe
    Zhuang, XiuJuan
    Cheng, Yingliang
    SURFACE & COATINGS TECHNOLOGY, 2020, 385
  • [24] Effects of electrical parameters and their interactions on plasma electrolytic oxidation coatings on aluminum substrates
    An, Ling-yun
    Ma, Ying
    Yan, Xiao-xu
    Wang, Sheng
    Wang, Zhan-ying
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2020, 30 (04) : 883 - 895
  • [25] Optical emission spectroscopy studies of discharge mechanism and plasma characteristics during plasma electrolytic oxidation of magnesium in different electrolytes
    Wang, Li
    Chen, Li
    Yan, Zongcheng
    Fu, Wen
    SURFACE & COATINGS TECHNOLOGY, 2010, 205 (06) : 1651 - 1658
  • [26] Corrosion and biological study on biofunctionalized porous coating on titanium produced by plasma electrolytic oxidation
    Valizade, Nima
    Aghdam, Alireza Sabour Rouh
    Jarjoura, George
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 688
  • [27] Effect of electrolyte on surface properties of pure titanium coated by plasma electrolytic oxidation
    Shin, Ki Ryong
    Ko, Young Gun
    Shin, Dong Hyuk
    JOURNAL OF ALLOYS AND COMPOUNDS, 2011, 509 : S478 - S481
  • [28] Response of variation of electrical control parameters to coatings prepared in organo-silicon electrolyte by plasma electrolytic oxidation
    Chen, Qiong
    Lei, Mengwei
    Chen, Ming-an
    CERAMICS INTERNATIONAL, 2024, 50 (22) : 47402 - 47417
  • [29] Plasma Electrolytic Oxidation (PEO) Process-Processing, Properties, and Applications
    Sikdar, Soumya
    Menezes, Pramod, V
    Maccione, Raven
    Jacob, Timo
    Menezes, Pradeep L.
    NANOMATERIALS, 2021, 11 (06)
  • [30] Fluoride Influence on the Properties of Oxide Layer Produced by Plasma Electrolytic Oxidation
    Kazanski, Barbara
    Kossenko, Alexei
    Lugovskoy, Alex
    Zinigrad, Michael
    DIFFUSION IN SOLIDS AND LIQUIDS VII, 2012, 326-328 : 498 - 503