Evaluation of intermediate - Z materials for X-ray imaging

被引:0
|
作者
Dekic, Maja [1 ]
Samic, Hasnija [2 ]
机构
[1] Fac Sci, Sarajevo, Bosnia & Herceg
[2] Fac Elect Engn, Sarajevo, Bosnia & Herceg
来源
TECHNICS TECHNOLOGIES EDUCATION MANAGEMENT-TTEM | 2011年 / 6卷 / 01期
关键词
pixellated detector; fluorescence; spatial resolution; X-ray imaging; DETECTORS; RADIATION;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper considers performances of compound intermediate-Z semiconductors for medical imaging. A model of planar pixel detector has been developed and a calculation of spatial resolution and contrast for intermediate- Z materials detectors performed, all that taking into account fluorescence that degrades image quality. There is also an illustration of improvements in image quality that these materials bring, based on comparison between spatial resolution and contrast achieved by these detectors as opposed to those made of materials currently in use for medical imaging. Finally, using the Rose model, which gives signal-to-noise ratio corresponding to a minimum detectable contrast, a minimum size of the object to be detected in the conditions of mammographic imaging with detectors made of GaAs, InP, CdTe and CsI has been determined.
引用
收藏
页码:179 / 183
页数:5
相关论文
共 50 条
  • [21] Emerging X-ray imaging technologies for energy materials
    Cao, Chuntian
    Toney, Michael F.
    Sham, Tsun-Kong
    Harder, Ross
    Shearing, Paul R.
    Xiao, Xianghui
    Wang, Jiajun
    MATERIALS TODAY, 2020, 34 : 132 - 147
  • [22] Low energy Kβ X-ray satellites of four intermediate Z atoms
    Koteswararao, V
    Reddy, Seetharami B.
    Narayana, Ram K.
    Sattar, Abdul S.
    Murti, V. R. M.
    Rao, D. P. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 479 : 194 - 199
  • [23] Evaluation and optimization of multimodal X-ray imaging techniques for inverse Compton X-ray sources
    Guenther, Benedikt
    Gradl, Regine
    Jud, Christoph
    Eggl, Elena
    Kulpe, Stephanie
    Braig, Eva-Maria
    Heck, Lisa
    Brantl, Johannes
    Achterhold, Klaus
    Gleich, Bernhard
    Dierolf, Martin
    Pfeiffer, Franz
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII, 2019, 11110
  • [24] Performance evaluation of CsI screens for X-ray imaging
    赵博震
    秦秀波
    冯召东
    魏存峰
    陈研
    王宝义
    魏龙
    Chinese Physics C, 2014, 38 (11) : 41 - 46
  • [25] Performance evaluation of CsI screens for X-ray imaging
    赵博震
    秦秀波
    冯召东
    魏存峰
    陈研
    王宝义
    魏龙
    Chinese Physics C, 2014, (11) : 41 - 46
  • [26] Performance evaluation of CsI screens for X-ray imaging
    Zhao Bo-Zhen
    Qin Xiu-Bo
    Feng Zhao-Dong
    Wei Cun-Feng
    Chen Yan
    Wang Bao-Yi
    Wei Long
    CHINESE PHYSICS C, 2014, 38 (11)
  • [27] Formal evaluation of quality of imaging in X-ray tomography
    Anikonov, D.S.
    Prokhorov, I.V.
    Doklady Akademii Nauk, 2005, 401 (03) : 312 - 315
  • [28] An evaluation of the EOS X-ray imaging system in pelvimetry
    Sigmann, M. -H.
    Delabrousse, E.
    Riethmuller, D.
    Runge, M.
    Peyron, C.
    Aubry, S.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (09) : 833 - 838
  • [29] X-RAY IMAGING
    HAY, GA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (05): : 377 - 386
  • [30] Lensless X-ray imaging of magnetic materials:: basic considerations
    Eisebitt, S
    Lörgen, M
    Eberhardt, W
    Lüning, J
    Stöhr, J
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2005, 80 (05): : 921 - 927