Computed tomography of refractive index by low-coherence interferometry

被引:0
|
作者
Wang, Yi [1 ,2 ]
Ma, Zhenhe [1 ]
Zhou, Hongxian [1 ]
机构
[1] Northeastern Univ, Sch Control Engn, Qinhuangdao, Peoples R China
[2] Foshan Univ, Sch Elect & Informat Engn, Foshan 528000, Peoples R China
来源
THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XXII | 2015年 / 9330卷
关键词
computed tomography; low-coherence interferometry; filter back-projection algorithm; refractive index; MICROSCOPY;
D O I
10.1117/12.2077075
中图分类号
TH742 [显微镜];
学科分类号
摘要
We present a 3D imaging system for simultaneously imaging the distributions of refractive index and optical absorption using a transmission Fourier-domain low-coherence interferometer. The forward-scattering light travelling through a sample interferes with a reference light beam. The projections of refractive index and optical absorption within the sample are calculated from measured interference fringes. We acquire the projections at sufficient angular views and reconstruct the distributions of refractive index and optical absorption using the filter back-projection algorithm. The proposed method is experimentally verified by using a plastic tube phantom.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] High-resolution computed tomography of refractive index distribution by transillumination low-coherence interferometry
    Wang, Yi
    Wang, Ruikang K.
    OPTICS LETTERS, 2010, 35 (01) : 91 - 93
  • [2] Measurement of PDMS Refractive Index by Low-Coherence Interferometry
    Kacik, Daniel
    Tatar, Peter
    Martincek, Ivan
    2014 ELEKTRO, 2014, : 662 - 665
  • [3] Air refractive index measurement using low-coherence interferometry
    Pikalek, Tomas
    Buchta, Zdenek
    APPLIED OPTICS, 2015, 54 (16) : 5024 - 5030
  • [4] Measurement of complex refractive index of human blood by low-coherence interferometry
    M. Jedrzejewska-Szczerska
    The European Physical Journal Special Topics, 2013, 222 : 2367 - 2372
  • [5] Measurement of complex refractive index of human blood by low-coherence interferometry
    Jedrzejewska-Szczerska, M.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2013, 222 (09): : 2367 - 2372
  • [6] Corneal group refractive index measurement using low-coherence interferometry
    Uhlhorn, SR
    Manns, F
    Tahi, H
    Rol, P
    Parel, JM
    OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 : 14 - 21
  • [7] Needle-based refractive index measurement using low-coherence interferometry
    Zysk, Adam M.
    Adie, Steven G.
    Armstrong, Julian J.
    Leigh, Matthew S.
    Paduch, Alexandre
    Sampson, David D.
    Nguyen, Freddy T.
    Boppart, Stephen A.
    OPTICS LETTERS, 2007, 32 (04) : 385 - 387
  • [8] Refractive index and dispersion measurement using low-coherence interferometry with broadband confocal scanning
    Francis, Daniel
    Ford, Helen D.
    Tatam, Ralph P.
    OPTICAL SENSING AND DETECTION V, 2018, 10680
  • [9] Simultaneous measurement of refractive index and thickness by combining low-coherence interferometry and confocal optics
    Kim, Seokhan
    Na, Jihoon
    Kim, Myoung Jin
    Lee, Byeong Ha
    OPTICS EXPRESS, 2008, 16 (08) : 5516 - 5526
  • [10] Dispersion-insensitive measurement of thickness and group refractive index by low-coherence interferometry
    Murphy, DF
    Flavin, DA
    APPLIED OPTICS, 2000, 39 (25) : 4607 - 4615