Validation of non-invasive arterial pressure monitoring during carotid endarterectomy

被引:34
作者
Heusdens, J. F. [1 ]
Lof, S. [2 ]
Pennekamp, C. W. A. [2 ]
Specken-Welleweerd, J. C. [2 ]
de Borst, G. J. [2 ]
van Klei, W. A. [1 ]
van Wolfswinkel, L. [1 ]
Immink, R. V. [1 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Anaesthesiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Vasc Surg, Utrecht, Netherlands
[3] Acad Med Ctr Amsterdam, Dept Anaesthesiol, H 1-158,POB 22660, NL-1100 DD Amsterdam, Netherlands
关键词
carotid endarterectomy; measurement techniques; arterial pressure; Nexfin; non-invasive continuous arterial pressure measurement; RANDOMIZED CONTROLLED-TRIALS; BLOOD-PRESSURE; CARDIAC-SURGERY; RADIAL ARTERY; STENOSIS; NEXFIN; PHENYLEPHRINE; METAANALYSIS; ANESTHESIA; MANAGEMENT;
D O I
10.1093/bja/aew268
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Patients undergoing carotid endarterectomy require strict arterial blood pressure (BP) control to maintain adequate cerebral perfusion. In this study we tested whether non-invasive beat-to-beat Nexfin finger BP (BPfin) can replace invasive beat-to-beat radial artery BP (BPrad) in this setting. Methods: In 25 consecutive patients (median age 71 yr) scheduled for carotid endarterectomy and receiving general anaesthesia, BPfin and BPrad were monitored simultaneously and ipsilaterally during the 30-min period surrounding carotid artery cross-clamping. Validation was guided by the standard set by the Association for the Advancement of Medical Instrumentation (AAMI), which considers a BP monitor adequate when bias (precision) is <5 (8) mm Hg, respectively. Results: BPfin, us BPrad bias (precision) was -3.3 (10.8), 6.1 (5.7) and 3.5 (5.2) mm Hg for systolic, diastolic, and mean BP, respectively. One subject was excluded due to a poor quality BP curve. In another subject, mean BPfin overestimated mean BPrad by 13.5 mm Hg. Conclusion: Mean BPfin could be considered as an alternative for mean BPrad during a carotid endarterectomy, based on the AAMI criteria. In 23 of 24 patients, the use of mean BPfin would not lead to decisions to adjust mean BPrad values outside the predefined BP threshold.
引用
收藏
页码:316 / 323
页数:8
相关论文
共 50 条
[31]   Validation study of Nexfin® continuous non-invasive blood pressure monitoring in critically ill adult patients [J].
Ameloot, K. ;
Van de Vijver, K. ;
Van Regenmortel, N. ;
De Laet, I. ;
Schoonheydt, K. ;
Dits, H. ;
Broch, O. ;
Bein, B. ;
Malbrain, M. L. N. G. .
MINERVA ANESTESIOLOGICA, 2014, 80 (12) :1294-1301
[32]   Continuous Non-invasive Arterial Pressure Assessment during Surgery to improve Outcome [J].
Stenglova, Alena ;
Benes, Jan .
FRONTIERS IN MEDICINE, 2017, 4
[33]   Non-invasive blood pressure monitoring in man [J].
Portaluppi, F .
PATHOLOGIE BIOLOGIE, 1996, 44 (03) :196-200
[34]   Continuous Non-Invasive Arterial Pressure Monitoring (ClearSight System) and Ankle Blood Pressure Measurements as Alternatives to Conventional Arm Blood Pressure [J].
Lee, Seohee ;
Chung, Jaeyeon ;
Bae, Jinyoung ;
Cho, Youn Joung ;
Nam, Karam ;
Jeon, Yunseok .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) :1-11
[35]   Carotid Body Baroreceptor Preservation and Control of Arterial Pressure in Eversion Carotid Endarterectomy [J].
Kotsis, Thomas ;
Christoforou, Panagitsa ;
Nastos, Konstantinos .
INTERNATIONAL JOURNAL OF ANGIOLOGY, 2020, 29 (01) :33-38
[36]   Non-Invasive Monitoring during Caesarean Delivery: Prevalence of Hypotension and Impact on the Newborn [J].
Vasile, Francesco ;
La Via, Luigi ;
Murabito, Paolo ;
Tigano, Stefano ;
Merola, Federica ;
Nicosia, Tiziana ;
De Masi, Giuseppe ;
Bruni, Andrea ;
Garofalo, Eugenio ;
Sanfilippo, Filippo ;
Theodoraki, Kassiani ;
Yang, Chun .
JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)
[37]   A comparison of continous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery [J].
Broch, O. ;
Bein, B. ;
Gruenewald, M. ;
Carstens, A. ;
Illies, C. ;
Schoeneich, F. ;
Steinfath, M. ;
Renner, J. .
MINERVA ANESTESIOLOGICA, 2013, 79 (03) :248-256
[38]   Monitoring of patients during carotid endarterectomy [J].
Kramár, F ;
Zoul, J ;
Mohapl, M ;
Benes, V .
CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 1999, 62 (04) :197-202
[39]   Cerebrovascular monitoring during carotid endarterectomy [J].
Babikian, VL ;
Cantelmo, NL .
STROKE, 2000, 31 (08) :1799-1801
[40]   Laser speckle contrast imaging of forehead cutaneous blood flow during carotid endarterectomy as a potential non-invasive method for surrogate monitoring of cerebral perfusion [J].
Mads J. Niemann ;
Jonas P. Eiberg ;
Henrik Sørensen ;
Niels H. Secher .
Journal of Clinical Monitoring and Computing, 2021, 35 :1263-1268