Cardiac CT: are we underestimating the dose? A radiation dose study utilizing the 2007 ICRP tissue weighting factors and a cardiac specific scan volume

被引:70
作者
Gosling, O. [1 ]
Loader, R. [1 ]
Venables, P. [1 ]
Rowles, N. [1 ]
Morgan-Hughes, G. [1 ]
Roobottom, C. [2 ]
机构
[1] Derriford Hosp, Plymouth Hosp NHS Trust, Plymouth PL6 8DH, Devon, England
[2] Univ Plymouth, Peninsula Coll Med & Dent, Plymouth PL4 8AA, Devon, England
关键词
TOMOGRAPHY CORONARY-ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; REDUCTION; RADIOLOGY;
D O I
10.1016/j.crad.2010.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To calculate the effective dose from cardiac multidetector computed tomography (MDCT) using a computer-based model utilizing the latest International Commission on Radiation Protection (ICRP) 103 tissue-weighting factors (2007), to compare this dose with those calculated with previously published chest conversion factors and to produce a conversion factor specific for cardiac MDCT. MATERIALS AND METHODS: An observational study of 152 patients attending for cardiac MDCT as part of their usual clinical care in a university teaching hospital. The dose for each examination was calculated using the computer-based anthropomorphic ImPACT model (the imaging performance assessment of CT scanners) and this was compared with the dose derived from the dose length product (DLP) and a chest conversion factor. RESULTS: The median effective dose calculated using the ImPACT calculator (4.5 mSv) was significantly higher than the doses calculated with the chest conversion factors (2.2-3 mSv). CONCLUSION: The use of chest conversion factors significantly underestimates the effective dose when compared to the dose calculated using the ImPACT calculator. A conversion factor of 0.028 would give a better estimation of the effective dose from prospectively gated cardiac MDCT. (C) 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1013 / 1017
页数:5
相关论文
共 20 条
  • [1] Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography
    Coles, DR
    Smail, MA
    Negus, IS
    Wilde, P
    Oberhoff, M
    Karsch, KR
    Baumbach, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) : 1840 - 1845
  • [2] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [3] Radiation Dose from Single-Heartbeat Coronary CT Angiography Performed with a 320-Detector Row Volume Scanner
    Einstein, Andrew J.
    Elliston, Carl D.
    Arai, Andrew E.
    Chen, Marcus Y.
    Mather, Richard
    Pearson, Gregory D. N.
    DeLaPaz, Robert L.
    Nickoloff, Edward
    Dutta, Ajoy
    Brenner, David J.
    [J]. RADIOLOGY, 2010, 254 (03) : 698 - 706
  • [4] Estimated Radiation Dose Associated With Cardiac CT Angiography
    Hausleiter, Joerg
    Meyer, Tanja
    Hermann, Franziska
    Hadamitzky, Martin
    Krebs, Markus
    Gerber, Thomas C.
    McCollough, Cynthia
    Martinoff, Stefan
    Kastrati, Adnan
    Schoemig, Albert
    Achenbach, Stephan
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (05): : 500 - 507
  • [5] ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology
    Hendel, Robert C.
    Patel, Manesh R.
    Kramer, Christopher M.
    Poon, Michael
    Hendel, Robert C.
    Brindis, Ralph G.
    Hendel, Robert C.
    Douglas, Pamela S.
    Peterson, Eric D.
    Wolk, Michael J.
    Allen, Joseph M.
    Patel, Manesh R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) : 1475 - 1497
  • [6] First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography
    Herzog, B. A.
    Wyss, C. A.
    Husmann, L.
    Gaemperli, O.
    Valenta, I.
    Treyer, V.
    Landmesser, U.
    Kaufmann, P. A.
    [J]. HEART, 2009, 95 (20) : 1656 - 1661
  • [7] Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
    Hsieh, Jiang
    Londt, John
    Vass, Melissa
    Li, Jay
    Tang, Xiangyang
    Okerlund, Darin
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4236 - 4248
  • [8] Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
  • [9] Effective dose: how should it be applied to medical exposures?
    Martin, C. J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (956) : 639 - 647
  • [10] Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography Comparison With Retrospective Electrocardiogram-Gated Helical Scan
    Maruyama, Takao
    Takada, Masanori
    Hasuike, Toshiaki
    Yoshikawa, Atsushi
    Namimatsu, Eiji
    Yoshizumi, Tohru
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (18) : 1450 - 1455