A window of one's own: a public office post-occupancy evaluation

被引:17
|
作者
Meir, Isaac A. [1 ]
Schwartz, Moshe [2 ]
Davara, Yosefa [3 ]
Garb, Yaakov [2 ]
机构
[1] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Inst Dryland Environm & Energy Res, Sede Boqer Campus, Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Social Studies, Sede Boqer Campus, Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Albert Katz Int Sch Desert Studies, Sede Boqer Campus, Beer Sheva, Israel
关键词
architectural design; indoor environment quality; personal control; post-occupancy evaluation; sick building syndrome; ventilation; windows; workplace satisfaction; PERCEIVED AIR-QUALITY; SYNDROME SBS SYMPTOMS; THERMAL COMFORT; PERFORMANCE; VENTILATION; BUILDINGS; IEQ;
D O I
10.1080/09613218.2018.1434366
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The prevalence of mechanical climatization in office buildings, alongside the dictate to conserve energy, has misguidedly promoted the construction of buildings with non-operable windows. Research shows that such buildings are detrimental to their occupants' wellbeing and productivity, sometimes causing them to feel overcooled or overheated. This post-occupancy evaluation illustrates such problems through the case study of a courthouse building in a hot arid environment. A strong association is shown between occupant satisfaction, building ventilation and sense of wellbeing at work. A positive correlation was found between satisfaction with personal control, and overall satisfaction survey results show that workers express a willingness to compromise future salary rises in order to receive operable windows. Key lessons for architects are discussed.
引用
收藏
页码:437 / 452
页数:16
相关论文
共 50 条
  • [41] Enhanced retrofitting process by integrating post-occupancy evaluation and user perception
    Wegertseder Martinez, Paulina
    Trebilcock Kelly, Maureen
    REVISTA DE LA CONSTRUCCION, 2018, 17 (03): : 499 - 516
  • [42] Post-occupancy evaluation of the thermal environment in a green building
    Gou, Zhonghua
    Lau, Stephen Siu-Yu
    FACILITIES, 2013, 31 (7-8) : 357 - 371
  • [43] Post-occupancy Evaluation and Thermal Comfort: State of the Art and New Approaches
    Gossauer, Elke
    Wagner, Andreas
    ADVANCES IN BUILDING ENERGY RESEARCH, 2007, 1 (01) : 151 - 175
  • [44] Get the picture? Lessons learned from a smartphone-based post-occupancy evaluation
    O'Brien, William
    Schweiker, Marcel
    Day, Julia K.
    ENERGY RESEARCH & SOCIAL SCIENCE, 2019, 56
  • [45] A Post-occupancy Evaluation of the Influence of Wood on Environmental Comfort
    Watchman, Melanie
    Potvin, Andre
    Demers, Claude M. H.
    BIORESOURCES, 2017, 12 (04): : 8704 - 8724
  • [46] POST-OCCUPANCY EVALUATION OF A UNIVERSITY SHOPPING MALL FACILITY
    Ahmed, Wahhaj
    Hassanain, Mohammad A.
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2020, 13 (02) : 5 - 15
  • [47] Post-Occupancy Indoor Environmental Quality Evaluation of Student Housing Facilities
    Hassanain, Mohammad A.
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2007, 3 (04) : 249 - 256
  • [48] Explainable Post-Occupancy Evaluation Using a Humanoid Robot
    Bonomolo, Marina
    Ribino, Patrizia
    Vitale, Gianpaolo
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 23
  • [49] Seeing is believing: an innovative approach to post-occupancy evaluation
    Julia K. Day
    Shelby Ruiz
    William O’Brien
    Marcel Schweiker
    Energy Efficiency, 2020, 13 : 473 - 486
  • [50] Post-Occupancy Evaluation: An Inevitable Step Toward Sustainability
    Meir, Isaac A.
    Garb, Yaakov
    Jiao, Dixin
    Cicelsky, Alex
    ADVANCES IN BUILDING ENERGY RESEARCH, 2009, 3 (01) : 189 - 219