Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images

被引:95
作者
De Cecco, Carlo Nicola [1 ,2 ]
Buffa, Vitaliano [1 ]
Fedeli, Stefano [1 ]
Luzietti, Monica [1 ]
Vallone, Andrea [1 ]
Ruopoli, Roberto [1 ]
Miele, Vittorio
Rengo, Marco [3 ]
Paolantonio, Pasquale [3 ]
Enrici, Michelangelo Maurizi [2 ]
Laghi, Andrea [3 ]
David, Vincenzo [2 ]
机构
[1] Osped San Camillo Forlanini, Dept Cardiovasc Radiol, I-00152 Rome, Italy
[2] Univ Roma La Sapienza, St Andrea Hosp, Dept Radiol Sci, I-00189 Rome, Italy
[3] Univ Rome Sapienza Polo Pontino, Dept Radiol Sci, I-04100 Latina, Italy
关键词
Dual energy computed tomography; Liver; Virtual unenhanced images; Iodine subtraction; Radiation dose; INITIAL-EXPERIENCE; CONTRAST MATERIAL; RENAL MASSES; REDUCTION; ABDOMEN; REPAIR;
D O I
10.1007/s00330-010-1874-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and noise of conventional unenhanced (CU) and virtual unenhanced (VU) images in patients who underwent hepatic dual energy computed tomography (DECT) and to assess potential radiation dose reduction. Forty consecutive patients were studied. Mean CU and VU image quality and noise were analyzed by two blinded radiologists using a five-point grade scale. The effective radiation dose of a triple-phase protocol (CU, arterial and DE portal phases) were compared with that of a dual-phase protocol (arterial and DE portal phases). No significant difference in mean image quality was observed between VU (3.92 +/- 0.85) and CU images (4.20 +/- 0.72). A significant difference in mean image noise was observed between VU and CU (P < 0.01). The dose reduction achieved by omitting the unenhanced acquisition was 30.47 +/- 7.07% (P < 0.01). In 6 patients, a complete VU liver image was not obtained. VU images can be obtained with similar image quality as CU. This approach favors a reduction in patient's radiation exposure. Nevertheless, a complete abdominal DECT is possible only in patients with a low body mass index, due technical limitations of the present DECT systems.
引用
收藏
页码:2870 / 2875
页数:6
相关论文
共 22 条
[1]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[2]   HEPATIC SPIRAL CT - REDUCTION OF DOSE OF INTRAVENOUS CONTRAST MATERIAL [J].
BRINK, JA ;
HEIKEN, JP ;
FORMAN, HP ;
SAGEL, SS ;
MOLINA, PL ;
BROWN, PC .
RADIOLOGY, 1995, 197 (01) :83-88
[3]   Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study [J].
Brown, C. L. ;
Hartman, R. P. ;
Dzyubak, O. P. ;
Takahashi, N. ;
Kawashima, A. ;
McCollough, C. H. ;
Bruesewitz, M. R. ;
Primak, A. M. ;
Fletcher, J. G. .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1289-1295
[4]   Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience [J].
Chae, Eun Jin ;
Song, Jae-Woo ;
Seo, Joon Beom ;
Krauss, Bernhard ;
Jang, Yu Mi ;
Song, Koun-Sik .
RADIOLOGY, 2008, 249 (02) :671-681
[5]   Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[6]   Dual energy computed tomography in tophaceous gout [J].
Choi, H. K. ;
Al-Arfaj, A. M. ;
Eftekhari, A. ;
Munk, P. L. ;
Shojania, K. ;
Reid, G. ;
Nicolaou, S. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (10) :1609-1612
[7]   The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography [J].
Ferda, Jiri ;
Novak, Milan ;
Mirka, Hynek ;
Baxa, Jan ;
Ferdova, Eva ;
Bednarova, Alena ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Klotz, Ernst ;
Kreuzberg, Boris .
EUROPEAN RADIOLOGY, 2009, 19 (10) :2518-2522
[8]   Basic Principles and Postprocessing Techniques of Dual-Energy CT: Illustrated by Selected Congenital Abnormalities of the Thorax [J].
Godoy, Myrna C. B. ;
Naidich, David P. ;
Marchiori, Edson ;
Assadourian, Bernard ;
Leidecker, Christianne ;
Schmidt, Bernhard ;
Vlahos, Ioannis .
JOURNAL OF THORACIC IMAGING, 2009, 24 (02) :152-159
[9]   Dose reduction and image quality in MDCT colonography using tube current modulation [J].
Graser, A. ;
Wintersperger, B. J. ;
Suess, C. ;
Reiser, M. F. ;
Becker, C. R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :695-701
[10]   Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images? [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Hecht, Elizabeth M. ;
Becker, Christoph R. ;
Leidecker, Christianne ;
Staehler, Michael ;
Stief, Christian G. ;
Hildebrandt, Henriette ;
Godoy, Myrna C. B. ;
Finn, Myra E. ;
Stepansky, Flora ;
Reiser, Maximilian F. ;
Macari, Michael .
RADIOLOGY, 2009, 252 (02) :433-440