Prospective comparison of 3-dimensional volume rendered computerized tomography and conventional renal arteriography for surgical planning in patients undergoing laparoscopic donor nephrectomy

被引:54
作者
Abou El Fettouh, H
Herts, BR
Nimeh, T
Wirth, SL
Caplin, A
Sands, M
Ramani, AP
Kaouk, J
Goldfarb, DA
Gill, IS
机构
[1] Cleveland Clin Fdn, Inst Urol, Sect Laparoscop & Minimally Invas Surg, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Inst Urol, Sect Renal Transplantat, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
关键词
kidney; nephrectomy; tomography; x-ray computed; angiography; laparoscopy;
D O I
10.1097/01.ju.0000068039.79654.d3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We prospectively assessed the accuracy of 3-dimensional (3-D) volume rendered computerized tomography (CT) and conventional renal arteriography to visualize renovascular anatomy in patients undergoing laparoscopic donor nephrectomy. Materials and Methods: A total of 60 consecutive patients undergoing laparoscopic donor nephrectomy (left side in 46 and right side in 14) prospectively underwent 3-D CT and renal angiography. A short videotape of 3-D CT was prepared using volume rendering software that demonstrated the anatomical location, number, anomalies and spatial interrelationships of the renal arteries and veins. These 3-D videotapes and arteriogram findings were directly correlated with intraoperative surgical findings at laparoscopy and during ex vivo bench preparation of the harvested kidney. The perceived intraoperative value of 3D-CT to delineate renovascular anatomical detail was scored subjectively by the laparoscopic surgeon for each case on a 10-point scale of 0-completely inaccurate to 10-completely accurate. Results: There were no complications related to the 3-D CT protocol and volume rendering was successful in all patients. Three-D CT accurately identified the number of renal arteries in 59 patients (98%). In I patient with 3 renal arteries 3-D CT and arteriogram each identified only 2. In the 46 patients undergoing left donor nephrectomy 3-D CT accurately identified the number of veins and venous anomalies in 45 (98%), including 2 with a circumaortic left renal vein. Another case of circumaortic vein was misdiagnosed as 2 renal veins. On the right side in 14 patients 3-D CT accurately identified the renal veins in 13 (94%) and missed 1 vein in a patient with 2 renal veins. Angiography correctly identified the number of renal veins in only 52 cases (87%). Furthermore, it misdiagnosed all 3 cases of circumaortic left renal vein. The laparoscopic surgeon believed that 3-D CT accurately identified the location and anatomical interrelationship of the renal vessels with precision. Mean subjective score +/- SEM was 8.5 +/- 1 for the arterial system, 8.6 +/- 1.1 for the venous system and 9.2 +/- 0.5 for any vascular anomalies. Conclusions: Three-D CT accurately identifies renal vascular anatomy in a manner that may facilitate renal hilar dissection during laparoscopic donor nephrectomy, especially during the initial surgeon experience. This imaging modality integrates essential information from angiography, venography and excretory urography into a single study, and it can obviate the need for more invasive vascular imaging in most cases.
引用
收藏
页码:57 / 60
页数:4
相关论文
共 15 条
  • [1] 3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery
    Coll, DM
    Uzzo, RG
    Herts, BR
    Davros, WJ
    Wirth, SL
    Novick, AC
    [J]. JOURNAL OF UROLOGY, 1999, 161 (04) : 1097 - 1102
  • [2] 3-DIMENSIONAL IMAGING
    FISHMAN, EK
    MAGID, D
    NEY, DR
    CHANEY, EL
    PIZER, SM
    ROSENMAN, JG
    LEVIN, DN
    VANNIER, MW
    KUHLMAN, JE
    ROBERTSON, DD
    [J]. RADIOLOGY, 1991, 181 (02) : 321 - 337
  • [3] RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY
    GALANSKI, M
    PROKOP, M
    CHAVAN, A
    SCHAEFER, CM
    JANDELEIT, K
    NISCHELSKY, JE
    [J]. RADIOLOGY, 1993, 189 (01) : 185 - 192
  • [4] SPIRAL(HELICAL) CT
    HEIKEN, JP
    BRINK, JA
    VANNIER, MW
    [J]. RADIOLOGY, 1993, 189 (03) : 647 - 656
  • [5] Triphasic helical CT of the kidneys: Contribution of vascular phase scanning in patients before urologic surgery
    Herts, BR
    Coll, DM
    Lieber, ML
    Streem, SB
    Novick, AC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (05) : 1273 - 1277
  • [6] Jacobs SC, 2000, J UROLOGY, V164, P1494, DOI 10.1016/S0022-5347(05)67014-0
  • [7] CT ANGIOGRAPHY WITH VOLUME RENDERING - IMAGING FINDINGS
    KUSZYK, BS
    HEATH, DG
    NEY, DR
    BLUEMKE, DA
    URBAN, BA
    CHAMBERS, TP
    FISHMAN, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 445 - 448
  • [8] Potential renal donors: Comparison of conventional imaging with helical CT
    Platt, JF
    Ellis, JH
    Korobkin, M
    Reige, KA
    Konnak, JW
    Leichtman, AB
    [J]. RADIOLOGY, 1996, 198 (02) : 419 - 423
  • [9] RATNER LE, 1995, TRANSPLANTATION, V60, P1047
  • [10] RUBIN GD, 1995, RADIOL CLIN N AM, V33, P51