Comparing the performance of traditional direct laryngoscope with three indirect laryngoscopes: A prospective manikin study in normal and difficult airway scenarios

被引:7
作者
Ong, Jiann-Ruey [2 ,3 ]
Chong, Chee-Fah [2 ,4 ]
Chen, Chien-Chih [6 ]
Wang, Tzong-Luen [2 ,4 ]
Lin, Chiu-Mei [2 ,5 ]
Chang, Shi-Chuan [1 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Chest Dept, Taipei 112, Taiwan
[2] Shin Kong Wu Ho Su Mem Hosp, Emergency Dept, Taipei, Taiwan
[3] Natl Yang Ming Univ, Sch Med, Inst Emergency & Crit Care Med, Taipei 112, Taiwan
[4] Fu Jen Catholic Univ, Sch Med, Taipei, Taiwan
[5] Taipei Med Univ, Coll Publ Hlth, Inst Injury Prevent & Control, Taipei, Taiwan
[6] Keelung Hosp, Dept Hlth, Emergency Dept, Keelung, Taiwan
关键词
emergency medicine; intratracheal; intubation; laryngoscopy; neck injury; IN-LINE STABILIZATION; CERVICAL-SPINE MOTION; TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; TRUVIEW EVO2(R); LIGHTED STYLET; MANAGEMENT; EMERGENCY; GLIDESCOPE(R); BLADE;
D O I
10.1111/j.1742-6723.2011.01441.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The aim of the present study was to evaluate the performance of three indirect laryngoscopes, Truview EVO2 laryngoscope, Clarus Levitan fiberoptic stylet and AirwayScope AWS, in comparison with direct Macintosh laryngoscope (ML) when performed in normal and difficult airway scenarios. Methods: This prospective comparative study recruited 30 emergency physicians familiar with direct laryngoscopic intubation. Intubations were performed on manikin and were repeated twice for both scenarios. The primary end points were intubation time and rate of failed intubation. Glottis visualization was graded on Cormack and Lehane score and VAS. Results: In normal airway scenario: AWS had shortest intubation time (6.0 s) followed by ML (8.7 s); VAS score of ML and AWS was lower (easier to use) than the other two devices; Cormack and Lehane score was similar for all devices. In difficult airway scenario: AWS had shortest intubation time (5.9 s); VAS score of AWS was lower than the other three devices; TVL, FOS, AWShad better Cormack and Lehane score than ML. Intubation time, rate of failed intubation, and Cormack and Lehane score were similar between attempts in both scenarios. Learning effect was significant in FOS in both scenarios and in TVL in normal airway scenario. Conclusions: AWS performed best in normal and difficult airways. ML performed better than TVL and FOS in normal airways. Performances of ML, TVL and FOS were similar in difficult airways. Skills with AWS could be mastered rapidly. TVL and FOS required more practice to gain expertise.
引用
收藏
页码:606 / 614
页数:9
相关论文
共 25 条
[1]   The failed intubation attempt in the Emergency Department: Analysis of prevalence, rescue techniques, and personnel [J].
Bair, AE ;
Filbin, MR ;
Kulkarni, RG ;
Walls, RM .
JOURNAL OF EMERGENCY MEDICINE, 2002, 23 (02) :131-140
[2]   A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study [J].
Evans, A ;
Morris, S ;
Petterson, J ;
Hall, JE .
ANAESTHESIA, 2006, 61 (05) :478-481
[3]   Caring for the patients with cervical spine injuries: what have we learned? [J].
Ghafoor, AU ;
Martin, TW ;
Gopalakrishnan, S ;
Viswamitra, S .
JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (08) :640-649
[4]   Airway Scope and StyletScope for Tracheal Intubation in a Simulated Difficult Airway [J].
Komatsu, Ryu ;
Kamata, Kotoe ;
Hamada, Keiko ;
Sessler, Daniel I. ;
Ozaki, Makoto .
ANESTHESIA AND ANALGESIA, 2009, 108 (01) :273-279
[5]  
Levitan RM, 1999, ANN EMERG MED, V33, P694, DOI 10.1016/S0196-0644(99)70199-X
[6]   An evaluation of the TruView EVO2 laryngoscope [J].
Li, J. B. ;
Xiong, Y. C. ;
Wang, X. L. ;
Fan, X. H. ;
Li, Y. ;
Xu, H. ;
Ma, Y. ;
Deng, X. M. .
ANAESTHESIA, 2007, 62 (09) :940-943
[7]   Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilization [J].
Malik, M. A. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 101 (05) :723-730
[8]   Comparison of the Glidescope®, the Pentax AWS®, and the Truview EVO2® with the Macintosh laryngoscope in experienced anaesthetists: a manikin study [J].
Malik, M. A. ;
O'Donoghue, C. ;
Carney, J. ;
Maharaj, C. H. ;
Harte, B. H. ;
Laffey, J. G. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :128-134
[9]   Manual in-line stabilization for acute airway management of suspected cervical spine injury: Historical review and current questions [J].
Manoach, Seth ;
Palladino, Lorenzo .
ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) :236-245
[10]   Airway Adjuncts [J].
Marco, Catherine A. ;
Marco, Alan P. .
EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2008, 26 (04) :1015-+