Modified carbon paste electrode for potentiometric dibromide pesticide in water and urine samples

被引:22
作者
Abu Shawish, Hazem M. [1 ]
Abu Ghalwa, Nasser [2 ]
Hamada, Mazen [2 ]
Basheer, Abdel-Hakem [2 ]
机构
[1] Al Aqsa Univ, Dept Chem, Coll Sci, Gaza, Israel
[2] Al Azhar Univ, Dept Chem, Gaza, Israel
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2012年 / 32卷 / 02期
关键词
Diquat dibromide; Ion-selective electrode; Pesticide; Potentiometry; Carbon paste electrode; Sensor; ION-SELECTIVE ELECTRODES; DIQUAT; MEMBRANE; PARAQUAT; SENSOR; COEFFICIENTS; PLASTICIZER; PERFORMANCE; REMOVAL; SERUM;
D O I
10.1016/j.msec.2011.10.008
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A carbon paste electrode for diquat dibromide (Dq.2Br) was prepared and fully characterized in terms of composition, usable pH range, response time and temperature. The electrode was applied to the potentiometric determination of diquat ions in water and urine samples with average recoveries of 97.5-104.0% and relative standard deviations of 0.30-4.73%. The electrode is based on the ion pair, namely, diquatphosphotungstate dissolved in 2-nitrophenyloctyl ether (2-NPOE) as pasting liquid with 1.0% Na-TPB as an additive. The modified electrode showed a near-Nernstian slope of 30.8 mV over the concentration range of 3.8 x 10(-6)to 1.0 x 10(-3) M with the limit of detection 9.0 x 10(-7) over the pH range 4.5-9.5. The electrode exhibits good selectivity for Dq cations with respect to a large number of inorganic cations. organic cations, sugars and amino acids. The proposed potentiometric method offers the advantages of simplicity, accuracy, automation feasibility and applicability to turbid and colored sample solutions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 145
页数:6
相关论文
共 35 条
[1]  
Abu-Shawish HM, 2007, CAN J ANAL SCI SPECT, V52, P225
[2]   A new chemically modified carbon paste electrode for determination of copper based on N,N'-disalicylidenehexameythylenediaminate copper(II) complex [J].
Abu-Shawish, Hazem M. ;
Saadeh, Salman M. .
SENSOR LETTERS, 2007, 5 (3-4) :565-571
[3]  
[Anonymous], 1988, HAZ SUBST DAT TOX DA
[4]   Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples [J].
Arvand, M. ;
Asadollahzadeh, S. A. .
TALANTA, 2008, 75 (04) :1046-1054
[5]   Coated wire lead(II) selective potentiometric sensor based on 4-tert-butylcalix[6]arene [J].
Bhat, VS ;
Ijeri, VS ;
Srivastava, AK .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :98-105
[6]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[7]   Gas chromatographic-mass spectrometric method for the determination of the herbicides paraquat and diquat in plasma and urine samples [J].
de Almeida, Rafael Menck ;
Yonamine, Mauricio .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2) :260-264
[8]   Investigation of square wave voltammetric detection of diquat at carbon paste electrode impregnated with Ca10(PO4)6F2:: Application in natural water samples [J].
El Mhammedi, M. A. ;
Akasse, M. B. ;
Chtaini, A. .
MATERIALS CHEMISTRY AND PHYSICS, 2008, 109 (2-3) :519-525
[9]   A carbon paste electrode modified with kaolin for the detection of diquat [J].
El Mhammedi, M. A. ;
Bakasse, M. ;
Najih, R. ;
Chtaini, A. .
APPLIED CLAY SCIENCE, 2009, 43 (01) :130-134
[10]   Novel and selective potentiometric membrane sensor for amiloride determination in pharmaceutical compounds and urine [J].
Ensafi, Ali A. ;
Allafchian, Ali R. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) :802-806