Diagnostic Yield of Colon Capsule Endoscopy in Detection of Superficial Colorectal Lesions

被引:12
|
作者
Otani, Ichiro [1 ]
Oka, Shiro [1 ]
Tanaka, Shinji [2 ]
Iio, Sumio [1 ]
Tsuboi, Akiyoshi [1 ]
Kunihara, Sayoko [1 ]
Hiyama, Yuichi [1 ]
Chayama, Kazuaki [1 ]
机构
[1] Hiroshima Univ Hosp, Dept Gastroenterol & Metab, Hiroshima, Japan
[2] Hiroshima Univ Hosp, Dept Endoscopy, Hiroshima, Japan
关键词
Colon capsule endoscopy; Colorectal superficial lesions; Sessile serrated adenoma; polyp; VIRTUAL CHROMOENDOSCOPY; CLINICAL-EFFICACY; COLONOSCOPY; MULTICENTER; POLYPS; ACCURACY;
D O I
10.1159/000499332
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The efficacy of second-generation PillCam -COLON2 capsule endoscopy (CCE2) in detecting colorectal superficial lesions remains unclear. Objective: We sought to determine the diagnostic yield of CCE2 in the detection of colorectal superficial lesions. Methods: We performed CCE2 in 60 consecutive patients between April 2011 and -December 2017. Lesions >= 6 mm in size were detected in 34 patients (25 males, average age: 60.5 years). We performed endoscopic resection and histopathological analysis of all resected lesions within 3 months after CCE2. We considered the optical colonoscopy (OC) findings as the gold standard and evaluated CCE2 sensitivity. Results: Sixty-seven lesions (>= 6 mm) were detected via OC, with 27 colorectal superficial lesions and 40 protruded lesions. CCE2 sensitivity for >= 6-mm-sized, superficial, and protruded lesions was 84, 78, and 88%, respectively. No significant intergroup differences were observed. CCE2 false-negative colorectal superficial lesions accounted for 31% of right-sided colon lesions and 50% of sessile serrated adenomas/polyps (SSA/Ps). The CCE2 false-negative protruded lesions accounted for 17% of right-sided colon lesions. Conclusion: CCE2 sensitivities for colorectal superficial and protruded lesions were not significantly different. However, flat-type SSA/Ps in the right colon, especially when the transit time is fast, have a risk of demonstrating CCE2 false-negative results.
引用
收藏
页码:262 / 269
页数:8
相关论文
共 50 条
  • [1] Dual camera colon capsule endoscopy increases detection of colorectal lesions
    Takamaru, Hiroyuki
    Yamada, Masayoshi
    Sakamoto, Taku
    Nakajima, Takeshi
    Saito, Yutaka
    Kakugawa, Yasuo
    Matsumoto, Minori
    Matsuda, Takahisa
    Ide, Daisuke
    Saito, Shoichi
    Gulati, Shraddha
    Tajiri, Hisao
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2016, 51 (12) : 1532 - 1533
  • [2] Artificial intelligence and colon capsule endoscopy: development of an automated diagnostic system of protruding lesions in colon capsule endoscopy
    M. M. Saraiva
    J. P. S. Ferreira
    H. Cardoso
    J. Afonso
    T. Ribeiro
    P. Andrade
    M. P. L. Parente
    R. N. Jorge
    G. Macedo
    Techniques in Coloproctology, 2021, 25 : 1243 - 1248
  • [3] Artificial intelligence and colon capsule endoscopy: development of an automated diagnostic system of protruding lesions in colon capsule endoscopy
    Saraiva, M. M.
    Ferreira, J. P. S.
    Cardoso, H.
    Afonso, J.
    Ribeiro, T.
    Andrade, P.
    Parente, M. P. L.
    Jorge, R. N.
    Macedo, G.
    TECHNIQUES IN COLOPROCTOLOGY, 2021, 25 (11) : 1243 - 1248
  • [4] Diagnostic yield of colon capsule endoscopy for Crohn's disease lesions in the whole gastrointestinal tract
    Yamada, Keisaku
    Nakamura, Masanao
    Yamamura, Takeshi
    Maeda, Keiko
    Sawada, Tsunaki
    Mizutani, Yasuyuki
    Ishikawa, Eri
    Ishikawa, Takuya
    Kakushima, Naomi
    Furukawa, Kazuhiro
    Ohno, Eizaburo
    Kawashima, Hiroki
    Honda, Takashi
    Ishigami, Masatoshi
    Fujishiro, Mitsuhiro
    BMC GASTROENTEROLOGY, 2021, 21 (01)
  • [5] Diagnostic yield of colon capsule endoscopy for Crohn’s disease lesions in the whole gastrointestinal tract
    Keisaku Yamada
    Masanao Nakamura
    Takeshi Yamamura
    Keiko Maeda
    Tsunaki Sawada
    Yasuyuki Mizutani
    Eri Ishikawa
    Takuya Ishikawa
    Naomi Kakushima
    Kazuhiro Furukawa
    Eizaburo Ohno
    Hiroki Kawashima
    Takashi Honda
    Masatoshi Ishigami
    Mitsuhiro Fujishiro
    BMC Gastroenterology, 21
  • [6] Flat colorectal lesions at pillcam colon capsule endoscopy (CCE)
    Spada, Cristiano
    Hassan, Cesare
    Grazioli, Leonardo Minelli
    Adler, Samuel
    Cesaro, Paola
    Petruzziello, Lucio
    Costamagna, Guido
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 31 - 31
  • [7] TOP 100 AND DETECTION OF COLORECTAL LESIONS IN COLON CAPSULE ENDOSCOPY: MORE THAN MEETS THE EYE
    Capela, Tiago Lima
    Ferreira, Ana Isabel
    Silva, Vitor Macedo
    Freitas, Marta
    Arieira, Catia
    Xavier, Sofia
    Goncalves, Tiago Curdia
    Carvalho, Pedro Boal
    Moreira, Maria Joao
    Rosa, Bruno
    Cotter, Jose
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB424 - AB425
  • [8] TOP 100 and detection of colorectal lesions in colon capsule endoscopy: more than meets the eye
    Capela, Tiago Lima
    Arieira, Catia
    Xavier, Sofia
    Goncalves, Tiago Curdia
    Carvalho, Pedro Boal
    Rosa, Bruno
    Cotter, Jose
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2024, 36 (09) : 1087 - 1092
  • [9] Capsule Endoscopy: Ways to Avoid Missing Lesions and to Optimize Diagnostic Yield
    Leighton, Jonathan A.
    Shiff, Arthur D.
    TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY, 2006, 8 (04) : 169 - 174
  • [10] Colon capsule endoscopy and its effectiveness in the diagnosis and management of colorectal neoplastic lesions
    Milluzzo, Sebastian Manuel
    Bizzotto, Alessandra
    Cesaro, Paola
    Spada, Cristiano
    EXPERT REVIEW OF ANTICANCER THERAPY, 2019, 19 (01) : 71 - 80