Acoustothermal heating of polydimethylsiloxane microfluidic system

被引:78
作者
Ha, Byung Hang [1 ]
Lee, Kang Soo [1 ]
Destgeer, Ghulam [1 ]
Park, Jinsoo [1 ]
Choung, Jin Seung [1 ]
Jung, Jin Ho [1 ]
Shin, Jennifer Hyunjong [1 ]
Sung, Hyung Jin [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon 305701, South Korea
基金
新加坡国家研究基金会;
关键词
POLYMERASE-CHAIN-REACTION; AMPLIFICATION; DEVICES; PCR;
D O I
10.1038/srep11851
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report an observation of rapid (exceeding 2,000 K/s) heating of polydimethylsiloxane (PDMS), one of the most popular microchannel materials, under cyclic loadings at high (similar to MHz) frequencies. A microheater was developed based on the finding. The heating mechanism utilized vibration damping in PDMS induced by sound waves that were generated and precisely controlled using a conventional surface acoustic wave (SAW) microfluidic system. The refraction of SAW into the PDMS microchip, called the leaky SAW, takes a form of bulk wave and rapidly heats the microchannels in a volumetric manner. The penetration depths were measured to range from 210 mu m to 1290 mu m, enough to cover most sizes of microchannels. The energy conversion efficiency was SAW frequency-dependent and measured to be the highest at around 30 MHz. Independent actuation of each interdigital transducer (IDT) enabled independent manipulation of SAWs, permitting spatiotemporal control of temperature on the microchip. All the advantages of this microheater facilitated a two-step continuous flow polymerase chain reaction (CFPCR) to achieve the billion-fold amplification of a 134 bp DNA amplicon in less than 3 min.
引用
收藏
页数:8
相关论文
共 32 条
[1]  
Ahid D. N., 1985, VIBRATION DAMPING, P123
[2]   Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: A review [J].
Ahmad, Farhan ;
Hashsham, Syed A. .
ANALYTICA CHIMICA ACTA, 2012, 733 :1-15
[3]   Portable nucleic acid thermocyclers [J].
Almassian, David R. ;
Cockrell, Lisa M. ;
Nelson, William M. .
CHEMICAL SOCIETY REVIEWS, 2013, 42 (22) :8769-8798
[4]   Comparison of Methods for Accurate Quantification of DNA Mass Concentration with Traceability to the International System of Units [J].
Bhat, Somanath ;
Curach, Natalie ;
Mostyn, Thomas ;
Bains, Gursharan Singh ;
Griffiths, Kate R. ;
Emslie, Kerry R. .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7185-7192
[5]   Trapping of DNA by thermophoretic depletion and convection [J].
Braun, D ;
Libchaber, A .
PHYSICAL REVIEW LETTERS, 2002, 89 (18) :1-188103
[6]   Nucleic acid amplification using microfluidic systems [J].
Chang, Chen-Min ;
Chang, Wen-Hsin ;
Wang, Chih-Hung ;
Wang, Jung-Hao ;
Mai, John D. ;
Lee, Gwo-Bin .
LAB ON A CHIP, 2013, 13 (07) :1225-1242
[7]   Circulating polymerase chain reaction chips utilizing multiple-membrane activation [J].
Chih-Hao Wang ;
Chen, Yi-Yu ;
Liao, Chia-Sheng ;
Hsieh, Tsung-Min ;
Luo, Ching-Hsing ;
Wu, Jiunn-Jong ;
Lee, Huei-Huang ;
Lee, Gwo-Bin .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (02) :367-375
[8]   Submicron separation of microspheres via travelling surface acoustic waves [J].
Destgeer, Ghulam ;
Ha, Byung Hang ;
Jung, Jin Ho ;
Sung, Hyung Jin .
LAB ON A CHIP, 2014, 14 (24) :4665-4672
[9]   Adjustable, rapidly switching microfluidic gradient generation using focused travelling surface acoustic waves [J].
Destgeer, Ghulam ;
Im, Sunghyuk ;
Ha, Byung Hang ;
Jung, Jin Ho ;
Ansari, Mubashshir Ahmad ;
Sung, Hyung Jin .
APPLIED PHYSICS LETTERS, 2014, 104 (02)
[10]   Surface acoustic wave microfluidics [J].
Ding, Xiaoyun ;
Li, Peng ;
Lin, Sz-Chin Steven ;
Stratton, Zackary S. ;
Nama, Nitesh ;
Guo, Feng ;
Slotcavage, Daniel ;
Mao, Xiaole ;
Shi, Jinjie ;
Costanzo, Francesco ;
Huang, Tony Jun .
LAB ON A CHIP, 2013, 13 (18) :3626-3649