Dual signal amplification for highly sensitive electrochemical detection of uropathogens via enzyme-based catalytic target recycling

被引:35
作者
Su, Jiao [1 ]
Zhang, Haijie [1 ]
Jiang, Bingying [2 ]
Zheng, Huzhi [1 ]
Chai, Yaqin [1 ]
Yuan, Ruo [1 ]
Xiang, Yun [1 ]
机构
[1] Southwest Univ, Sch Chem & Chem Engn, Key Lab Luminescence & Real Time Anal, Minist Educ, Chongqing 400715, Peoples R China
[2] Chongqing Univ Technol, Sch Chem & Chem Engn, Chongqing 400054, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Layer-by-layer self-assemblies; Pathogen detection; Quantum dots; Signal amplification; Target recycling; DNA MICROARRAYS; PATHOGEN DETECTION; ESCHERICHIA-COLI; ANTHRACIS SPORES; BIOSENSORS; HYBRIDIZATION; EXONUCLEASE; PCR; OLIGONUCLEOTIDE; TRANSDUCTION;
D O I
10.1016/j.bios.2011.08.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We report an ultrasensitive electrochemical approach for the detection of uropathogen sequence-specific DNA target. The sensing strategy involves a dual signal amplification process, which combines the signal enhancement by the enzymatic target recycling technique with the sensitivity improvement by the quantum dot (QD) layer-by-layer (LBL) assembled labels. The enzyme-based catalytic target DNA recycling process results in the use of each target DNA sequence for multiple times and leads to direct amplification of the analytical signal. Moreover, the LBL assembled QD labels can further enhance the sensitivity of the sensing system. The coupling of these two effective signal amplification strategies thus leads to low femtomolar (5 fM) detection of the target DNA sequences. The proposed strategy also shows excellent discrimination between the target DNA and the single-base mismatch sequences. The advantageous intrinsic sequence-independent property of exonuclease Ill over other sequence-dependent enzymes makes our new dual signal amplification system a general sensing platform for monitoring ultralow level of various types of target DNA sequences. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 43 条
  • [1] Detection of Salmonella spp. using microsphere-based, fiber-optic DNA microarrays
    Ahn, S
    Walt, DR
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (15) : 5041 - 5047
  • [2] A rapid biosensor for viable B-anthracis spores
    Baeumner, AJ
    Leonard, B
    McElwee, J
    Montagna, RA
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) : 15 - 23
  • [3] Bacterial species determination from DNA-DNA hybridization by using genome fragments and DNA microarrays
    Cho, JC
    Tiedje, JM
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (08) : 3677 - 3682
  • [4] Amplified potentiometric transduction of DNA hybridization using ion-loaded liposomes
    Chumbimuni-Torres, Karin Y.
    Wu, Jie
    Clawson, Corbin
    Galik, Michal
    Walter, Anne
    Flechsig, Gerd-Uwe
    Bakker, Eric
    Zhang, Liangfang
    Wang, Joseph
    [J]. ANALYST, 2010, 135 (07) : 1618 - 1623
  • [5] A universal platform for sensitive and selective colorimetric DNA detection based on Exo III assisted signal amplification
    Cui, Liang
    Ke, Guoliang
    Zhang, Wei Yun
    Yang, Chaoyong James
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) : 2796 - 2800
  • [6] Direct enzyme-amplified electrical recognition of a 30-base model oligonucleotide
    deLumleyWoodyear, T
    Campbell, CN
    Heller, A
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (23) : 5504 - 5505
  • [7] Electrochemical DNA sensors based on enzyme dendritic architectures:: An approach for enhanced sensitivity
    Domínguez, E
    Rincón, O
    Narváez, A
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (11) : 3132 - 3138
  • [8] Nanomaterial-based electrochemical DNA sensing strategies
    Erdem, Arzum
    [J]. TALANTA, 2007, 74 (03) : 318 - 325
  • [9] Cantilever biosensors
    Fritz, Juergen
    [J]. ANALYST, 2008, 133 (07) : 855 - 863
  • [10] Simultaneous detection of marine fish pathogens by using multiplex PCR and a DNA microarray
    González, SF
    Krug, MJ
    Nielsen, ME
    Santos, Y
    Call, DR
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) : 1414 - 1419