Calculation of ocular single-pass modulation transfer function and retinal image simulation from measurements of the polarized double-pass ocular point spread function

被引:10
作者
Kobayashi, K
Shibutani, M
Takeuchi, G
Ohnuma, K
Miyake, Y
Negishi, K
Ohno, K
Noda, T
机构
[1] Topcon Corp, Ctr Res & Dev, Itabashi Ku, Tokyo 1758580, Japan
[2] Chiba Univ, Res Ctr Frontier Med Engn, Inage Ku, Chiba, Japan
[3] Chiba Univ, Res Ctr Frontier Med Engn, Fac Engn, Inage Ku, Chiba, Japan
[4] Keio Univ, Sch Med, Dept Ophthalmol, Shinjuku Ku, Tokyo 1608582, Japan
[5] Natl Tokyo Med Ctr, Dept Ophthalmol, Meguro Ku, Tokyo 1520982, Japan
关键词
modulation transfer function; point spread function; polarization; double-pass technique; retinal image; retinal image contrast;
D O I
10.1117/1.1627777
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The single-pass modulation transfer function (MTFsgl) is an important numerical parameter that can help elucidate the performance and some processes of the human visual system. In previous studies, the MTFsgl was calculated from double-pass point spread function (PSF) measurements. These measurements include a depolarized reflection component from the retina that introduces a measurement artifact, and they require long acquisition times to allow averaging to reduce speckle. To solve these problems, we developed a new ocular PSF analysis system (PSFAS) that uses polarization optics to eliminate the depolarized retinal reflection component, and a rotating prism to increase measurement speed. Validation experiments on one patient showed that the MTFsgl measured by PSFAS agrees closely with the MTF calculated from contrast sensitivity measurements. A simulated retinal image was calculated by convolution of Landolt rings with the calculated single-pass PSF provided by the PSFAS. The contrast characteristic then was calculated from the simulated retinal images. These results indicate that the MTFsgl obtained using the PSFAS may be a reliable measure of visual performance of the optics of the eye, including the optical effects of the retina. The simulated retinal images and contrast characteristics are useful for evaluating visual performance. (C) 2004 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:154 / 161
页数:8
相关论文
共 27 条
[1]   ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :195-201
[2]   EFFECTS OF AGING IN RETINAL IMAGE QUALITY [J].
ARTAL, P ;
FERRO, M ;
MIRANDA, I ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07) :1656-1662
[3]   DOUBLE-PASS MEASUREMENTS OF THE RETINAL-IMAGE QUALITY WITH UNEQUAL ENTRANCE AND EXIT PUPIL SIZES AND THE REVERSIBILITY OF THE EYES OPTICAL-SYSTEM [J].
ARTAL, P ;
IGLESIAS, I ;
LOPEZGIL, N ;
GREEN, DG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (10) :2358-2366
[4]   MONOCHROMATIC MODULATION TRANSFER-FUNCTION OF THE HUMAN EYE FOR DIFFERENT PUPIL DIAMETERS - AN ANALYTICAL EXPRESSION [J].
ARTAL, P ;
NAVARRO, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (01) :246-249
[5]  
Blokland G. V., 1986, VISION RES, V26, P485
[6]  
BLOKLAND GJ, 1985, J OPT SOC AM A, V2, P72
[7]   OPTICAL AND RETINAL FACTORS AFFECTING VISUAL RESOLUTION [J].
CAMPBELL, FW ;
GREEN, DG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 181 (03) :576-+
[8]   PSYCHOPHYSICAL MEASUREMENT OF THE BLUR ON THE RETINA DUE TO OPTICAL ABERRATIONS OF THE EYE [J].
CAMPBELL, MCW ;
HARRISON, EM ;
SIMONET, P .
VISION RESEARCH, 1990, 30 (11) :1587-+
[9]  
CHARMAN W N, 1980, British Journal of Physiological Optics, V34, P34
[10]   OBJECTIVE MEASUREMENTS OF LONGITUDINAL CHROMATIC ABERRATION OF HUMAN EYE [J].
CHARMAN, WN ;
JENNINGS, JAM .
VISION RESEARCH, 1976, 16 (09) :999-1005