Selective, Ultra-Sensitive, and Rapid Detection of Serotonin by Optimized ZnO Nanorod FET Biosensor

被引:14
|
作者
Sinha, K. [1 ]
Chakraborty, B. [2 ]
Chaudhury, S. Som [1 ]
Chaudhuri, C. Roy [2 ]
Chattopadhyay, S. K. [3 ]
Das Mukhopadhyay, C. [1 ]
机构
[1] IIEST, Ctr Healthcare Sci & Technol, Howrah 711103, India
[2] IIEST, Dept Elect & Telecommun Engn, Howrah 711103, India
[3] IIEST, Dept Chem, Howrah 711103, India
关键词
Zinc oxide; II-VI semiconductor materials; Biosensors; Field effect transistors; Sensitivity; Immune system; Zinc; Serotonin; zinc oxide nanorod; neurological disorder; optimization; FIELD-EFFECT TRANSISTOR; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; SURFACE; DOPAMINE; PLASMA; SENSOR; BLOOD; ASSAY;
D O I
10.1109/TNB.2021.3112534
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Fluctuation in serotonin (5-HT) level is an essential manifestation of several neurological disorders. In view of such importance, it is necessary to monitor the levels of 5-HT with good sensitivity, selectivity, affordability and low response time. Zinc oxide (ZnO) based field effect transistors (FET) with attributes like minimized noise levels and large on-off ratio are regarded as emerging high performance biosensor platforms. However, their response is significantly non-linear and there has been no appreciable endeavor for improving the non-linearity. Method: In this paper, we have introduced embedded gate electrode encompassing the channel of the FET which improves the uniformity in electric field line distribution through the electrolyte and proportionately enhances the capture of target biomolecule at ultra-low concentrations, thereby increasing the linearity. Further, we have incorporated the optimized parameters of ZnO nanorods reported previously, for rapid and selective detection of 5-HT. Results: It has been observed that the fabricated ZnO FET biosensor lowers the detection limit down to 0.1fM which is at least one order of magnitude lower than the existing reports. The sensor also has wide linear range from 0.1fM to 1nM with a detection time of about 20 minutes. Conclusion: The proposed zinc oxide nanorod-based sensor can be used as an excellent tool for future diagnosis of neurological disorders.
引用
收藏
页码:65 / 74
页数:10
相关论文
共 50 条
  • [1] Ultra-sensitive label-free biosensor for doxorubicin detection by doxorubicin optimized aptamer
    Wei, Luke
    Wang, Honglei
    Wu, Jiamin
    Mao, Jing
    Wang, Shijing
    Qiu, Jieqiong
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 139
  • [2] A comprehensive biosensor integrated with a ZnO nanorod FET array for selective detection of glucose, cholesterol and urea
    Ahmad, Rafiq
    Tripathy, Nirmalya
    Park, Jin-Ho
    Hahn, Yoon-Bong
    CHEMICAL COMMUNICATIONS, 2015, 51 (60) : 11968 - 11971
  • [3] Ultra-sensitive detection of cysteine by gold nanorod assembly
    Huang, Haowen
    Liu, Xuanyong
    Hu, Tao
    Chu, Paul K.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) : 2078 - 2083
  • [4] High throughput cellular biosensor for the ultra-sensitive, ultra-rapid detection of aflatoxin M1
    Larou, Evangelia
    Yiakoumettis, Iakovos
    Kaltsas, Grigoris
    Petropoulos, Anastasios
    Skandamis, Panagiotis
    Kintzios, Spiridon
    FOOD CONTROL, 2013, 29 (01) : 208 - 212
  • [5] ZnO nanorod-based FET biosensor for continuous glucose monitoring
    Zong, Xianli
    Zhu, Rong
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 2448 - 2453
  • [6] Highly Stable InSe-FET Biosensor for Ultra-Sensitive Detection of Breast Cancer Biomarker CA125
    Ji, Hao
    Wang, Zhenhua
    Wang, Shun
    Wang, Chao
    Zhang, Kai
    Zhang, Yu
    Han, Lin
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [7] Ultra-sensitive 2-nitrophenol detection based on reduced graphene oxide/ZnO nanocomposites
    Alam, Mohammad K.
    Rahman, Mohammed M.
    Abbas, Mohamed
    Torati, Sri Ramulu
    Asiri, Abdullah M.
    Kim, Dojin
    Kim, CheolGi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 66 - 73
  • [8] Aptamer-based microcantilever-array biosensor for ultra-sensitive and rapid detection of okadaic acid
    Wang, Yu
    Rao, Depeng
    Wu, Xiaoping
    Zhang, Qingchuan
    Wu, Shangquan
    MICROCHEMICAL JOURNAL, 2021, 160
  • [9] Rapid, Selective, and Ultra-Sensitive Field Effect Transistor-Based Detection of Escherichia coli
    Zaidan, Liena
    Novodchuk, Inna
    Xu, Alexander H.
    Nica, Alexandru
    Takaloo, Saeed
    Lloyd, Christopher
    Karimi, Reza
    Sanderson, Joe
    Bajcsy, Michal
    Yavuz, Mustafa
    MATERIALS, 2024, 17 (15)
  • [10] Detection of the p53 Gene Mutation Using an Ultra-sensitive and Highly Selective Electrochemical DNA Biosensor
    Fernando Garcia-Melo, Luis
    Chagoya Pio, Norma Andrea
    Morales-Rodriguez, Miguel
    Madrigal-Bujaidar, Eduardo
    Madrigal-Santillan, Eduardo O.
    Alvarez-Gonzalez, Isela
    Pineda Cruces, Rosa N.
    Batina, Nikola
    JOURNAL OF THE MEXICAN CHEMICAL SOCIETY, 2023, 67 (01) : 33 - 45