Conventional and modified MPPT techniques with direct control and dual scaled adaptive step-size

被引:37
作者
Amir, Aamir [1 ]
Amir, Asim [1 ]
Selvaraj, Jeyraj [1 ]
Rahim, Nasrudin A. [1 ,2 ]
Abusorrah, Abdullah M. [2 ]
机构
[1] Univ Malaya, UM Power Energy Dedicated Adv Ctr, Wisma R&D, Level 4,Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
[2] King Abdulaziz Univ, Renewable Energy Res Grp, Jeddah 21589, Saudi Arabia
关键词
Buck converter; Maximum Power Point (MPP) Tracking (MPPT); Modified Incremental Conductance method (mIncCond); Photovoltaic (PV) array modelling; Adaptive step-size; INCREMENTAL CONDUCTANCE MPPT; TRACKING; ENERGY; PERFORMANCE; ALGORITHM; SIMULATION; PERTURB; OBSERVE;
D O I
10.1016/j.solener.2017.09.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Conventionally, for adaptive MPPT change in power over change of voltage (dP(PV)/dV(PV)), change in power over change of current (dP(PV)/dI(PV)) or change in power over change of duty (dP(PV)/dD) had been utilized for variable stepping. However, this paper presents dual scaled adaptive step sizing, depending on change of power (dP(PV)). This technique reduces complexity, improves transient and dynamic response to sudden irradiance changes. As, PV characteristic curve has two different slopes, one at the left and the other at the right of MPP. Nevertheless, a constant fine-tuned scaling factor for operation at left of MPP may cause overshoot or undershoot at right side of MPP. Similarly, constant scaling factor offering good performance at right slope of the MPP may give slow voltage response when the system operates at left of MPP. Therefore, dual scale adaptive technique dependent on change of power (dP(PV)) has been proposed to attain credible performance at both sides of the slope. This technique has been employed on conventional and modified MPPT schemes with direct control, explicitly on modified Incremental Conductance (IncCond) method. Further, the aim is to establish the fact that even with direct implementation, IncCond remains a specific implementation of P & O, by comparatively analyzing the performance of each method. Simulation and experimental results authenticate the validity of the proposed scheme.
引用
收藏
页码:1017 / 1031
页数:15
相关论文
共 27 条
[1]   Modified Adaptive Variable Step-Size MPPT Based-on Single Current Sensor [J].
Ahmed, Emad M. ;
Shoyama, Masahito .
TENCON 2010: 2010 IEEE REGION 10 CONFERENCE, 2010, :1235-1240
[2]   Designing an integrated daylighting system for deep-plan spaces in Malaysian low-rise buildings [J].
Al-Obaidi, Karam M. ;
Munaaim, M. Arkam C. ;
Ismail, Muhammad Azzam ;
Rahman, Abdul Malik Abdul .
SOLAR ENERGY, 2017, 149 :85-101
[3]   Modified Perturb and Observe (P&O) with checking algorithm under various solar irradiation [J].
Alik, Rozana ;
Jusoh, Awang .
SOLAR ENERGY, 2017, 148 :128-139
[4]   Study of the MPP tracking algorithms: Focusing the numerical method techniques [J].
Amir, A. ;
Amir, A. ;
Selvaraj, J. ;
Rahim, N. A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 62 :350-371
[5]   A compact SiC photovoltaic inverter with maximum power point tracking function [J].
Ando, Yuji ;
Oku, Takeo ;
Yasuda, Masashi ;
Shirahata, Yasuhiro ;
Ushijima, Kazufumi ;
Murozono, Mikio .
SOLAR ENERGY, 2017, 141 :228-235
[6]  
Ascione F, 2017, SOL ENERGY
[7]   On the analytical approach for modeling photovoltaic systems behavior [J].
Cubas, Javier ;
Pindado, Santiago ;
Victoria, Marta .
JOURNAL OF POWER SOURCES, 2014, 247 :467-474
[8]  
Hart D.W., 2011, POWER ELECT HDB
[9]   Improving time series prediction of solar irradiance after sunrise: Comparison among three methods for time series prediction [J].
Hirata, Yoshito ;
Aihara, Kazuyuki .
SOLAR ENERGY, 2017, 149 :294-301
[10]   Realization of manufacturing dye-sensitized solar cells with possible maximum power conversion efficiency and durability [J].
Hosseinnezhad, Mozhgan ;
Saeb, Mohammad Reza ;
Garshasbi, Samira ;
Mohammadi, Yousef .