Canine and molar movement, rotation and tipping by NiTi coils versus elastomeric chains in first maxillary premolar extraction orthodontic adolescents: A randomized split-mouth study

被引:5
作者
Hashemzadeh, Haleh [1 ]
Soleimani, Milad [2 ]
Golbar, Mona [3 ]
Soltani, Anahita Dehghani [4 ]
Mirmalek, Seyedeh Pegah [5 ]
机构
[1] Univ Tehran Med Sci, Sch Dent, Dept Orthodont, Tehran, Iran
[2] Alborz Univ Med Sci, Sch Dent, Dept Orthodont, Karaj, Iran
[3] Shahed Univ Med Sci, Sch Dent, Dept Orthodont, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Dent, Dept Orthodont, Tehran, Iran
[5] Islamic Azad Univ, Tehran Med Sci, Sch Dent, Dept Orthodont, Tehran, Iran
关键词
Canine retraction; NiTi closed coil; Elastomeric chain; Anchorage loss; Space closure; SPACE CLOSURE; FORCE DECAY; TITANIUM; RETRACTION; SPRINGS;
D O I
10.1016/j.ortho.2021.11.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose > The primary objective was to compare canine and molar movement between NiTi coil and elastomeric chains. The secondary objective was to compare the side effects of these techniques (rotation and tipping). Materials and methods > This single-blind randomized split-mouth clinical trial was done prospectively. Healthy patients who needed extraction of the first maxillary premolars and did not require anchorage reinforcement techniques for orthodontic treatment were included. Following initial levelling and alignment a dental cast and panoramic radiographs were taken (pre-space closure documents) and canine retraction was done using elastomeric chains on one side and NiTi closed coil spring on the other side. After four months, the same documents were taken and movement (mm), as well as rotation (degree) and tipping (degree) of canines and first molars, were calculated by comparison of pre and post space closure documents by a blinded examiner. Data were analysed by independent samples t-test and Mann-Whitney U test with a significance level of 0.0125. Results > Overall 20 patients completed the study. The average canine movement was 3.88 and 5.45 mm (distal movement) in elastomeric chains and NiTi coil groups, respectively (P = 0.001). For molars, the movement was 1.20 and 1.15 mm (mesial movement), respectively (P = 0.529). The mean rotation of the canine in elastomeric chains and NiTi coil groups were 4.50 degrees and 7.43 degrees (mesiobuccal rotation), respectively (P = 0.006). For the molars, the mean rotation was 0.23 degrees and 1.90 degrees (mesiolingual rotation), respectively (P = 0.307). Average tipping of the canine in elasto-meric chains and NiTi coil groups were 4.52 degrees and 7.55 degrees (distal tipping), respectively (P = 0.011). For the molars, the numbers were 1.45 degrees and 4.80 degrees (mesial tipping), respectively (P = 0.028). Conclusion > Canine retraction by NiTi coil springs is faster compared to elastomeric powerchains with the cost of more canine tipping and rotation and more molar tipping. No significant difference was found in molar movement, rotation and tipping between the two techniques.
引用
收藏
页数:7
相关论文
共 25 条
  • [1] Color stability and force decay of clear orthodontic elastomeric chains: An in vitro study
    Aldrees, Abdullah M.
    Al-Foraidi, Sahal A.
    Murayshed, Mohammed S.
    Almoammar, Khalid A.
    [J]. INTERNATIONAL ORTHODONTICS, 2015, 13 (03) : 287 - 301
  • [2] Comprehensive comparison of canine retraction using NiTi closed coil springs vs elastomeric chains: A split-mouth randomized controlled trial
    Barsoum, Haya A.
    ElSayed, Hend S.
    El Sharaby, Fouad A.
    Palomo, Juan Martin
    Mostafa, Yehya A.
    [J]. ANGLE ORTHODONTIST, 2021, 91 (04) : 441 - 448
  • [3] Bokas Jim, 2006, Aust Orthod J, V22, P39
  • [4] Comparison of mesiodistal root angulation with posttreatment panoramic radiographs and cone-beam computed tomography
    Bouwens, Daniel G.
    Cevidanes, Lucia
    Ludlow, John B.
    Phillips, Ceib
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (01) : 126 - 132
  • [5] Dixon V, 2002, J Orthod, V29, P31
  • [6] Eslamipour Faezeh, 2017, J Contemp Dent Pract, V18, P527
  • [7] A systematic review of force decay in orthodontic elastomeric power chains
    Halimi, Abdelali
    Benyahia, Hicham
    Doukkali, Anas
    Azeroual, Mohamed-Faouzi
    Zaoui, Fatima
    [J]. INTERNATIONAL ORTHODONTICS, 2012, 10 (03) : 223 - 240
  • [8] Javanmardi Zahra, 2016, J Dent Res Dent Clin Dent Prospects, V10, P99, DOI 10.15171/joddd.2016.016
  • [9] Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
    Kanuru, Ravi Krishna
    Azaneen, Mustafa
    Narayana, Veera
    Kolasani, Balaram
    Indukuri, Ravikishore Reddy
    Babu, Firoz P.
    [J]. JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2014, 4 (04) : S32 - S37
  • [10] Khanemasjedi M, 2017, INT ORTHOD, V15, P561, DOI 10.1016/j.ortho.2017.09.011