Strain behavior of malaligned cervical spine implanted with metal-on-polyethylene, metal-on-metal, and elastomeric artificial disc prostheses - A finite element analysis

被引:17
作者
Chen, Wen-Ming [1 ]
Jin, Jie [2 ]
Park, Taehyung [3 ]
Ryu, Kyeong-Sik [4 ]
Lee, Sung-Jae [3 ]
机构
[1] Univ Shanghai Sci & Technol, Dept Biomed Engn, 516 JunGong Rd, Shanghai, Peoples R China
[2] YanBian Univ Hosp, Dept Orthoped Surg, Yanbian, Peoples R China
[3] Inje Univ, Coll Biomed Sci & Engn, Dept Biomed Engn, 607 O Bang, Gimhae 621749, Gyongnam, South Korea
[4] Catholic Univ Korea, Coll Med, Dept Neurosurg, 222 Banpo Daero, Seoul, South Korea
关键词
Spine; Artificial disc; Elastomeric prostheses; Strain behavior; Finite element analysis; ADJACENT-LEVEL; BIOMECHANICAL EVALUATION; KINEMATIC ANALYSIS; SAGITTAL BALANCE; IN-VIVO; ARTHROPLASTY; PRESSURE; BRYAN; UNIT;
D O I
10.1016/j.clinbiomech.2018.08.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Postoperative alterations in cervical spine curvature (i.e. loss of lordotic angle) are frequently observed following total disc replacement surgery. However, it remains unclear whether such changes in lordotic angle are due to preoperative spinal deformities and/or prostheses design limitations. The objective of the study is to investigate strain and segmental biomechanics of the malaligned cervical spine following total disc replacement. Methods: Three disc prostheses were chosen, namely a metal-on-polyethylene, a metal-on-metal, and an elastomeric prosthesis, which feature different geometrical and material design characteristics. All discs were modelled and implanted into multi-segmental cervical spine finite element model (C3-C7) with normal, straight and kyphotic alignments. Comparative analyses were performed by using a hybrid protocol. Findings: The results indicated that as the spine loses lordotic alignment, the prosthesis with elastomeric core tends to produce significantly larger flexion range of motion (difference up to 6.1 degrees) than metal-on-polyethylene and metal-on-metal prostheses. In contrast, when the treated spine had normal lordotic alignment, the range of motion behaviors of different prostheses are rather similar (difference within 1.9 degrees). Large localized strains up to 84.8% were found with the elastomeric prosthesis, causing a collapsed anterior disc space under flexion loads. Interpretation: Changes in cervical spinal alignments could significantly affect the surgical-level range of motion behaviors following disc arthroplasty; the in situ performance was largely dependent on the designs of the artificial disc devices in particular to the material properties.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 34 条
[1]   Sagittal Cervical Alignment After Cervical Disc Arthroplasty and Anterior Cervical Discectomy and Fusion Results of a Prospective, Randomized, Controlled Trial [J].
Anakwenze, Okechukwu A. ;
Auerbach, Joshua D. ;
Milby, Andrew H. ;
Lonner, Baron S. ;
Balderston, Richard A. .
SPINE, 2009, 34 (19) :2001-2007
[2]  
[Anonymous], 41 STAPP CAR CRASH C
[3]   The prevalence of indications and contraindications to cervical total disc replacement [J].
Auerbach, Joshua D. ;
Jones, Kristofer J. ;
Fras, Christian I. ;
Balderston, Jessica R. ;
Rushton, Scott A. ;
Chin, Kingsley R. .
SPINE JOURNAL, 2008, 8 (05) :711-716
[4]   Complications and strategies for revision surgery in total disc replacement [J].
Bertagnoli, R ;
Zigler, J ;
Karg, A ;
Voigt, S .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2005, 36 (03) :389-+
[5]   Changes in adjacent-level disc pressure and facet joint force after cervical arthroplasty compared with cervical discectomy and fusion [J].
Chang, Ung-Kyu ;
Kim, Daniel H. ;
Lee, Max C. ;
Willenberg, Rafer ;
Kim, Se-Hoon ;
Lim, Jesse .
JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (01) :33-39
[6]   In Situ Contact Analysis of the Prosthesis Components of Prodisc-L in Lumbar Spine Following Total Disc Replacement [J].
Chen, Wen-Ming ;
Park, ChunKun ;
Lee, KwonYong ;
Lee, SungJae .
SPINE, 2009, 34 (20) :E716-E723
[7]   Cervical Disk Arthroplasty Versus ACDF for Preoperative Reducible Kyphosis [J].
Chen, Yu ;
Wang, Xinwei ;
Lu, Xuhua ;
Yang, Haisong ;
Chen, Deyu .
ORTHOPEDICS, 2013, 36 (07) :E958-E965
[8]   Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment [J].
Clausen, JD ;
Goel, VK ;
Traynelis, VC ;
Scifert, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :342-347
[9]  
Dahl Michael C, 2011, SAS J, V5, P48, DOI 10.1016/j.esas.2011.01.002
[10]   Adjacent level intradiscal pressure and segmental kinematics following a cervical total disc arthroplasty -: An In Vitro human cadaveric model [J].
Dmitriev, AE ;
Cunningham, BW ;
Hu, NB ;
Sell, G ;
Vigna, F ;
McAfee, PC .
SPINE, 2005, 30 (10) :1165-1172