Analysis of the Impact of the Construction of a Trombe Wall on the Thermal Comfort in a Building Located in Wrocaw, Poland

被引:19
作者
Blotny, Jagoda [1 ]
Nems, Magdalena [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Mech & Power Engn, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
Trombe wall; thermal comfort; passive heating systems; heat accumulation; PERFORMANCE ANALYSIS; VENETIAN BLIND; SOLAR WALL; ENERGY; SYSTEM; SIMULATION; BEHAVIOR; STORAGE; DESIGN;
D O I
10.3390/atmos10120761
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Changes in climate, which in recent years have become more and more visible all over the world, have forced scientists to think about technologies that use renewable energy sources. This paper proposes a passive solar heating and cooling system, which is a Trombe wall located on the southern facade of a room measuring 4.2 m x 5.2 m x 2.6 m in Wrocaw, Poland. The studies were carried out by conducting a series of numerical simulations in the Ansys Fluent 16.0 environment in order to examine the temperature distribution and air circulation in the room for two representative days during the heating and cooling period, i.e., 16 January and 15 August (for a Typical Meteorological Year). A temperature increase of 1.11 degrees C and a temperature decrease in the morning and afternoon hours of 2.27 degrees C was obtained. Two options for optimizing the passive heating system were also considered. The first involved the use of triple glazing filled with argon in order to reduce heat losses to the environment, and for this solution, a temperature level that was higher by 8.50 degrees C next to the storage layer and an increase in the average room temperature by 1.52 degrees C were achieved. In turn, the second solution involved changing the wall material from concrete to brick, which resulted in a temperature increase of 0.40 degrees C next to the storage layer.
引用
收藏
页数:14
相关论文
共 50 条
[21]   Thermal comfort evaluation in a mechanically ventilated office building located in a continental climate [J].
Soutullo, S. ;
Enriquez, R. ;
Jimenez, M. J. ;
Heras, M. R. .
ENERGY AND BUILDINGS, 2014, 81 :424-429
[22]   Thermal and Vibration Comfort Analysis of a Nearly Zero-Energy Building in Poland [J].
Fedorczak-Cisak, Malgorzata ;
Furtak, Marcin ;
Gintowt, Jolanta ;
Kowalska-Koczwara, Alicja ;
Pachla, Filip ;
Stypula, Krzysztof ;
Tatara, Tadeusz .
SUSTAINABILITY, 2018, 10 (10)
[23]   Numerical Analysis on the Optimisation of Thermal Comfort Levels in an Office Located inside a Historical Building [J].
de Volo, Eleonora Palka Bayard ;
Pulvirenti, Beatrice ;
Jahanbin, Aminhossein ;
Guidorzi, Paolo ;
Semprini, Giovanni .
APPLIED SCIENCES-BASEL, 2023, 13 (05)
[24]   The experimental and theoretical analysis on a Trombe wall with photo-thermal composite catalytic purification blinds [J].
Li, Niansi ;
Fan, Miaomiao ;
Gu, Tao ;
Li, Yulin ;
Yu, Bendong ;
Ji, Jie .
BUILDING AND ENVIRONMENT, 2023, 238
[25]   A New Energy Saving Building Type -Cavity Construction System with Trombe Wall [J].
Liu, Yi ;
Yang, Dingyi .
DIGITAL MANUFACTURING & AUTOMATION III, PTS 1 AND 2, 2012, 190-191 :409-+
[26]   CFD analysis of the impact of air gap width on Trombe wall performance [J].
Friji, Khaoula ;
Ghriss, Ons ;
Bouabidi, Abdallah ;
Cuce, Erdem ;
Alshahrani, Saad .
ENERGY SCIENCE & ENGINEERING, 2024, 12 (10) :4598-4612
[27]   Enhancing indoor thermal comfort and energy efficiency: A comparative study of RC-PCM Trombe wall performance [J].
Liu, Huifang ;
Tan, Qianli ;
Shi, Ying ;
Yu, Bendong ;
Zhang, Mingyi .
RENEWABLE ENERGY, 2024, 227
[28]   Thermal comfort in a building with Trombe wall integrated with phase change materials in hot summer and cold winter region without air conditioning [J].
Li J. ;
Zhang Y. ;
Zhu Z. ;
Zhu J. ;
Luo J. ;
Peng F. ;
Sun X. .
Energy and Built Environment, 2024, 5 (01) :58-69
[29]   Effect of PV-Trombe wall in the multi-storey building on standard effective temperature (SET)-based indoor thermal comfort [J].
Xiao, Lan ;
Qin, Liang-Liang ;
Wu, Shuang-Ying .
ENERGY, 2023, 263
[30]   IMPROVING THERMAL STABILITY AND REDUCTION OF ENERGY CONSUMPTION BY IMPLEMENTING TROMBE WALL CONSTRUCTION IN THE PROCESS OF BUILDING DESIGN: The Serbia Region [J].
Bogdanovic, Veliborka B. ;
Randjelovic, Dusan J. ;
Vasov, Miomir S. ;
Ignjatovic, Marko G. ;
Stevanovic, Jelena N. .
THERMAL SCIENCE, 2018, 22 (06) :2355-2365