Solar Assisted Ground Source Heat Pump in Cold Climates

被引:21
作者
Emmi, Giuseppe [1 ]
Zarrella, Angelo [1 ]
De Carli, Michele [1 ]
Galgaro, Antonio [2 ]
机构
[1] Univ Padua, Dept Ind Engn, Appl Phys Sect, Via Venezia 1, I-35131 Padua, Italy
[2] Univ Padua, Dept Geosci, I-35131 Padua, Italy
来源
70TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, ATI2015 | 2015年 / 82卷
关键词
borehole heat exchangers; heat pump; solar thermal systems; cold climates; SAGSHP; SYSTEMS;
D O I
10.1016/j.egypro.2015.12.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
The geotherrnal heat pump(or ground source heat pump) uses the ground as heat source or sink for heating and cooling respectively. The design of the borehole field is the key element of these systems since the wrong evaluation of the boreholes' length affects the initial costs and/or the energy performance of the heat hump. The geothermal heat pumps are considered as renewable energy technologies, consequently can help the community to reduce the primary energy uses and also the CO2 emissions. However the sustainability and efficiency are ensured in the long period only when the heat balance through the ground is guaranteed. This work evaluates the thermal behavior of ground source heat humps in cold climates, where the thermal load profile of buildings is not balanced between heating and cooling, especially in residential sector characterized by low internal loads. In these contexts, the heat pump mainly works in heating mode, extracting continuously heat from the ground. As a result, the ground temperature decreases gradually during the years affecting the energy performance of the heat pump. A possible solution to this problem is to use solar thermal collectors to stabilize or gradually increase the mean ground temperature(these systems are called Solar Assisted Ground Source Heat. Pump - SAGSHP). In this work a. multi floors residential building with 12 flats (88 m(2) each)is analyzed in three climate zones, making use of the simulation tool TRNSYS. Different configurations of the plant system have been investigated and the case without the solar thermal collectors has been considered as reference. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:623 / 629
页数:7
相关论文
共 9 条
[1]  
[Anonymous], 2012, INTRO THERMOGEOLOGY
[2]  
Culver G., 1999, GEOHEAT CTR Q B, V3, P1
[3]   An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump [J].
Dong, Jiankai ;
Deng, Shiming ;
Jiang, Yiqiang ;
Xia, Liang ;
Yao, Yang .
APPLIED THERMAL ENGINEERING, 2012, 37 :380-387
[4]  
Fard A, 2015, APPL THERM ENG, V78, P695
[5]  
Kavanaugh S.P, 1997, ASHRAE APPL HDB
[6]   General review of ground-source heat pump systems for heating and cooling of buildings [J].
Sarbu, Ioan ;
Sebarchievici, Calin .
ENERGY AND BUILDINGS, 2014, 70 :441-454
[7]   Geothermal heat pump systems: Status review and comparison with other heating options [J].
Self, Stuart J. ;
Reddy, Bale V. ;
Rosen, Marc A. .
APPLIED ENERGY, 2013, 101 :341-348
[8]   Experimental study of a ground-coupled heat pump combined with thermal solar collectors [J].
Trillat-Berdal, V. ;
Souyri, B. ;
Fraisse, G. .
ENERGY AND BUILDINGS, 2006, 38 (12) :1477-1484
[9]   Performance prediction of a hybrid solar ground-source heat pump system [J].
Wang, Enyu ;
Fung, Alan S. ;
Qi, Chengying ;
Leong, Wey H. .
ENERGY AND BUILDINGS, 2012, 47 :600-611