Patients with breast cancer and negative sentinel lymph node biopsy without additional axillary lymph node dissection:: A follow-up study of up to 5 years

被引:13
|
作者
Domenech, Anna [1 ]
Benitez, Ana
Bajen, Maria Teresa
Pla, Maria Jesus
Gil, Miguel
Martin-Comin, Josep
机构
[1] Univ Hosp Bellvitge, IDIBELL, Dept Nucl Med, ES-08907 Barcelona, Spain
[2] Univ Hosp Bellvitge, IDIBELL, Dept Gynecol, Barcelona, Spain
关键词
breast cancer; sentinel node; axillary lymph node dissection; axillary recurrence;
D O I
10.1159/000111085
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To analyze the rate of axillary recurrences and survival in patients operated on for breast cancer who had not undergone an axillary lymph node dissection (ALND) because of a negative sentinel node biopsy. Methods: The study includes 97 patients operated on for breast cancer and selective node biopsy from June 2000 to December 2001 who had a negative sentinel node biopsy and did not undergo ALND. Mean age was 58.2 years (55.9 -60.5). Follow-up was done up to 5 years. After surgery all patients underwent clinical examination. Complementary treatment depended on the hospital protocol. Rate of axillary recurrences, presence of distant metastases and survival (Kaplan-Meier method) were studied. Results: After a median follow-up of 4.1 years (2.18-5.25), only 2/95 patients (2.1%) developed distant metastases. Four patients died but only the death of the patient who presented multiple metastases was related to the primary breast cancer (1%). The 5-year overall survival rate was 96%. Conclusions: (1) Only 1/95 patients studied developed nodal extra-axillary recurrence together with distant metastases. (2) The results obtained support the selective sentinel node biopsy as an accurate technique in the axillary stratification of patients with breast cancer, offering in the cases of negative sentinel node biopsy a safe axillary control after a 5-year follow-up. Copyright (c) 2007 S. Karger AG, Basel.
引用
收藏
页码:27 / 32
页数:6
相关论文
共 50 条
  • [1] Sentinel lymph node biopsy alone without axillary lymph node dissection - Follow up of sentinel lymph node negative breast cancer patients
    Reitsamer, R
    Peintinger, F
    Prokop, E
    Rettenbacher, L
    Menzel, C
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (01) : S60 - S60
  • [2] Sentinel lymph node biopsy alone without axillary lymph node dissection - follow up of sentinel lymph node negative breast cancer patients
    Reitsamer, R
    Peintinger, F
    Prokop, E
    Menzel, C
    Cimpoca, W
    Rettenbacher, L
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2003, 29 (03): : 221 - 223
  • [3] Follow-up of sentinel node negative breast cancer patients without axillary lymph node dissection
    Schrenk, P
    Hatzl-Griesenhofer, M
    Shamiyeh, A
    Waynad, W
    JOURNAL OF SURGICAL ONCOLOGY, 2001, 77 (03) : 165 - 170
  • [4] Axillary recurrences after sentinel lymph node biopsy: A multicentre analysis and follow-up of sentinel lymph node negative breast cancer patients
    van Wely, B. J.
    van den Wildenberg, F. J. H.
    Gobardhan, P.
    van Dalen, T.
    Rinkes, I. H. M. Borel
    Theunissen, E. B. M.
    Wijsman, J. H.
    Ernst, M.
    van der Pol, C. C.
    Madsen, E. V. E.
    Vles, W. J.
    Wauters, C. A. P.
    de Wilt, J. H. W.
    Strobbe, L. J. A.
    EJSO, 2012, 38 (10): : 925 - 931
  • [5] The risk of axillary relapse after sentinel lymph node biopsy for breast cancer is comparable with that of axillary lymph node dissection - A follow-up study of 4008 procedures
    Naik, AM
    Fey, J
    Gemignani, M
    Heerdt, A
    Montgomery, L
    Petrek, J
    Port, E
    Sacchini, V
    Sclafani, L
    VanZee, K
    Wagman, R
    Borgen, PI
    Cody, HS
    ANNALS OF SURGERY, 2004, 240 (03) : 462 - 468
  • [6] False negative sentinel lymph node biopsy; follow up of 391 sentinel lymph node negative breast cancer patients
    van Wely, B. J.
    Strobbe, L. J.
    Smidt, M. L.
    de Kievit, I. M.
    ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (02) : 45 - 45
  • [7] The risk of axillary relapse after sentinel lymph node biopsy for breast cancer is comparable with that of axillary lymph node dissection - A follow-up study of 4008 procedures - Discussions
    Bland, KI
    Cody, HS
    Ross, MI
    Easter, DW
    Leong, SPL
    Morrow, M
    Strasberg, SM
    ANNALS OF SURGERY, 2004, 240 (03) : 468 - 471
  • [8] Impact of Omission of Axillary Lymph Node Dissection After Negative Sentinel Lymph Node Biopsy: 70-Month Follow-up
    Hee Jeong Kim
    Byung Ho Son
    Woo Sung Lim
    Jin Yong Seo
    Beom Seok Koh
    Jong Won Lee
    Gyung Yup Gong
    Sei Hyun Ahn
    Annals of Surgical Oncology, 2010, 17 : 2126 - 2131
  • [9] Impact of Omission of Axillary Lymph Node Dissection After Negative Sentinel Lymph Node Biopsy: 70-Month Follow-up
    Kim, Hee Jeong
    Son, Byung Ho
    Lim, Woo Sung
    Seo, Jin Yong
    Koh, Beom Seok
    Lee, Jong Won
    Gong, Gyung Yup
    Ahn, Sei Hyun
    ANNALS OF SURGICAL ONCOLOGY, 2010, 17 (08) : 2126 - 2131
  • [10] Omitting axillary lymph node dissection in sentinel node negative breast cancer patients is safe: A long term follow-up analysis
    Torrenga, H
    Fabry, H
    Van der Sijp, JRM
    Van Diest, PJ
    Pijpers, R
    Meijer, S
    JOURNAL OF SURGICAL ONCOLOGY, 2004, 88 (01) : 4 - 7