Automated Tube Voltage Selection in Thoracoabdominal Computed Tomography at High Pitch Using a Third-Generation Dual-Source Scanner Image Quality and Radiation Dose Performance

被引:46
|
作者
Lurz, Markus [1 ]
Lell, Michael M. [1 ,2 ]
Wuest, Wolfgang [1 ]
Eller, Achim [1 ]
Scharf, Michael [1 ]
Uder, Michael [1 ,2 ]
May, Matthias Stefan [1 ,2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Imaging Sci Inst, Erlangen, Germany
关键词
tube voltage; dual-source CT; high pitch; chest; abdomen; image quality; CORONARY CT ANGIOGRAPHY; CURRENT MODULATION; ITERATIVE RECONSTRUCTIONS; KILOVOLT SELECTION; ABDOMINAL CT; REDUCTION; CHEST; STANDARD; PHANTOM; EXPOSURE;
D O I
10.1097/RLI.0000000000000133
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The objective of this study was to evaluate the radiation dose and image quality performance of thoracoabdominal examinations with an automated tube voltage selection (tube voltage adaptation), tube current modulation, and high pitch using a third-generation dual-source computed tomography (CT) compared intraindividually with 120-kV examinations with tube current modulation with special attention on clinically relevant lesions in the liver, the lungs, and extrahepatic soft tissues. Materials and Methods: This study was approved by the institutional review board. Computed tomography of the body was performed using a third-generation dual-source systemin 95 patients (mean body mass index, 25 kg/m(2); range, 18-35 kg/m(2)). For 49 of these patients, all calculated tube settings and resulting dose values were recorded for each of the 12 gradual contrast weightings of the tube voltage adaptation algorithm. Spiral CTwas performed for all patients with an intermediate weighting (grade 7) in a portal venous phase at 120 reference kV, 180 reference mAs, and pitch of 1.55. Objective image quality was assessed on the basis of contrast-to-noise ratio. Subjective image quality was assessed on the basis of clarity and sharpness of anatomical and pathological structures aswell as interfering beam hardening and spiral and motion artifacts (heart, lungs, diaphragm). Previous examinations on a 64-slice scanner served as reference. Results: All examinationswere rated good or excellent for clinical diagnosis. Automated tube voltage selection resulted in significantly lower effective radiation dose (9.5 mSv) compared with the reference (12.0 mSv; P < 0.01). Contrast-to-noise ratio and image quality of soft tissue lesions were significantly increased (P < 0.01). Motion artifacts were significantly reduced (P < 0.01). Conclusions: Automated tube voltage adaptation combined with high-pitch protocols allows for a substantial radiation dose reduction while substantially increasing the image quality, even at large-volume exposure.
引用
收藏
页码:352 / 360
页数:9
相关论文
共 50 条
  • [21] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Ochs, Marco M.
    Siepen, Fabian Aus Dem
    Fritz, Thomas
    Andre, Florian
    Gitsioudis, Gitsios
    Korosoglou, Grigorios
    Seitz, Sebastian
    Bogomazov, Yuriy
    Schlett, Christopher L.
    Sokiranski, Roman
    Sommer, Andre
    Gueckel, Friedemann
    Brado, Matthias
    Kauczor, Hans-Ulrich
    Goerich, Johannes
    Friedrich, Matthias G. W.
    Katus, Hugo A.
    Buss, Sebastian J.
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (07) : 485 - 492
  • [22] Image Quality of Coronary Arteries on Non-electrocardiography-gated High-Pitch Dual-Source Computed Tomography in Children with Congenital Heart Disease
    Kanie, Yuichiro
    Sato, Shuhei
    Tada, Akihiro
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2017, 38 (07) : 1393 - 1399
  • [23] Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose
    Lell, M. M.
    May, M. S.
    Brand, M.
    Eller, A.
    Buder, T.
    Hofmann, E.
    Uder, M.
    Wuest, W.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (07) : 1225 - 1230
  • [24] Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study
    Meinel, Felix G.
    Canstein, Christian
    Schoepf, U. Joseph
    Sedlmaier, Martin
    Schmidt, Bernhard
    Harris, Brett S.
    Flohr, Thomas G.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2014, 24 (07) : 1643 - 1650
  • [25] Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
    Zhang, Wei-Guo
    Liu, Jia-Ping
    Jia, Xiu-Qin
    Zhang, Ji-Yang
    Li, Xiang-Nan
    Yang, Qi
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 1033 - 1039
  • [26] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [27] Dual-source cardiac computed tomography: image quality and dose considerations
    Achenbach, Stephan
    Anders, Katharina
    Kalender, Willi A.
    EUROPEAN RADIOLOGY, 2008, 18 (06) : 1188 - 1198
  • [28] Third-Generation Dual-Source Computed Tomography for Coronary Angiography With Individually Tailored Scan Protocols Can Achieve a Low Radiation Dose With Good Image Quality in Unselected Patients
    Basar, Yeliz
    Akbas, Tugana
    Alis, Deniz
    Ulus, Sila
    Topel, Cagdas
    Sanli, Deniz Esin Tekcan
    Karaarslan, Ercan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 41 - 49
  • [29] Dual-source cardiac computed tomography: image quality and dose considerations
    Stephan Achenbach
    Katharina Anders
    Willi A. Kalender
    European Radiology, 2008, 18 : 1188 - 1198
  • [30] Trends in radiation dose and image quality for pediatric patients with a multidetector CT and a third-generation dual-source dual-energy CT
    Andrea Agostini
    Alberto Mari
    Cecilia Lanza
    Nicolo’ Schicchi
    Alessandra Borgheresi
    Stefania Maggi
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 745 - 752