Quantitative Amyloid Imaging Using Image-Derived Arterial Input Function

被引:19
|
作者
Su, Yi [1 ,3 ]
Blazey, Tyler M. [1 ]
Snyder, Abraham Z. [1 ]
Raichle, Marcus E. [1 ]
Hornbeck, Russ C. [1 ,3 ]
Aldea, Patricia [3 ]
Morris, John C. [2 ,3 ]
Benzinger, Tammie L. S. [1 ,3 ,4 ]
机构
[1] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Dept Neurol, St Louis, MO 63110 USA
[3] Washington Univ, Sch Med, Knight Alzheimers Dis Res Ctr ADRC, St Louis, MO 63110 USA
[4] Washington Univ, Sch Med, Dept Neurosurg, St Louis, MO 63110 USA
来源
PLOS ONE | 2015年 / 10卷 / 04期
关键词
POSITRON-EMISSION-TOMOGRAPHY; PITTSBURGH COMPOUND-B; ALZHEIMERS-DISEASE; GRAPHICAL ANALYSIS; COMPARTMENTAL ANALYSIS; COGNITIVE IMPAIRMENT; C-11; FLUMAZENIL; PRION DISEASE; HUMAN BRAIN; PET DATA;
D O I
10.1371/journal.pone.0122920
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Amyloid PET imaging is an indispensable tool widely used in the investigation, diagnosis and monitoring of Alzheimer's disease (AD). Currently, a reference region based approach is used as the mainstream quantification technique for amyloid imaging. This approach assumes the reference region is amyloid free and has the same tracer influx and washout kinetics as the regions of interest. However, this assumption may not always be valid. The goal of this work is to evaluate an amyloid imaging quantification technique that uses arterial region of interest as the reference to avoid potential bias caused by specific binding in the reference region. 21 participants, age 58 and up, underwent Pittsburgh compound B (PiB) PET imaging and MR imaging including a time-of-flight (TOF) MR angiography (MRA) scan and a structural scan. FreeSurfer based regional analysis was performed to quantify PiB PET data. Arterial input function was estimated based on coregistered TOF MRA using a modeling based technique. Regional distribution volume (V-T) was calculated using Logan graphical analysis with estimated arterial input function. Kinetic modeling was also performed using the estimated arterial input function as a way to evaluate PiB binding (DVRkinetic) without a reference region. As a comparison, Logan graphical analysis was also performed with cerebellar cortex as reference to obtain DVRREF. Excellent agreement was observed between the two distribution volume ratio measurements (r>0.89, ICC>0.80). The estimated cerebellum V-T was in line with literature reported values and the variability of cerebellum V-T in the control group was comparable to reported variability using arterial sampling data. This study suggests that image-based arterial input function is a viable approach to quantify amyloid imaging data, without the need of arterial sampling or a reference region. This technique can be a valuable tool for amyloid imaging, particularly in population where reference normalization may not be accurate.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Quantitative hemodynamic PET imaging using image-derived arterial input function and a PET/MR hybrid scanner
    Su, Yi
    Vlassenko, Andrei G.
    Couture, Lars E.
    Benzinger, Tammie L. S.
    Snyder, Abraham Z.
    Derdeyn, Colin P.
    Raichle, Marcus E.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (04): : 1435 - 1446
  • [2] Image-derived arterial input function for quantitative fluorescence imaging of receptor-drug binding in vivo
    Elliott, Jonathan T.
    Samkoe, Kimberley S.
    Davis, Scott C.
    Gunn, Jason R.
    Paulsen, Keith D.
    Roberts, David W.
    Pogue, Brian W.
    JOURNAL OF BIOPHOTONICS, 2016, 9 (03) : 282 - 295
  • [3] Quantification of cerebral metabolic rate of oxygen with image-derived arterial input function
    Su, Yi
    Vlassenko, Andrei
    Derdeyn, Colin
    Benzinger, Tammie
    Raichle, Marcus
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Quantification of cerebral metabolic rate of oxygen with image-derived arterial input function
    Su, Yi
    Vlassenko, Andrei
    Derdeyn, Colin
    Benzinger, Tammie
    Raichle, Marcus
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [5] Image-derived input function for brain imaging using the high-resolution research tomograph
    Zanotti-Fregonara, Paolo
    Liow, Jeih-San
    Fujita, Masahiro
    Zoghbi, Sami S.
    Comtat, Claude
    Elise, Luong
    Boellaard, Ronald
    Pike, Victor W.
    Innis, Robert B.
    NEUROIMAGE, 2010, 52 : S222 - S222
  • [6] Image-Derived Input Function for Brain PET Quantification
    Gorgulho, Andre
    Caramelo, Francisco
    Patricio, Miguel
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [7] Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney
    Feng, Tao
    Tsui, Benjamin M. W.
    Li, Xin
    Vranesic, Melin
    Lodge, Martin A.
    Gulaldi, Nedim C. M.
    Szabo, Zsolt
    MEDICAL PHYSICS, 2015, 42 (11) : 6736 - 6744
  • [8] Application of calibrated image-derived input function to a clinical protocol
    Zanotti-Fregonara, Paolo
    Lyoo, Chul Hyoung
    Bar-Hen, Avner
    Liow, Jeih-San
    Zoghbi, Sami S.
    Fujita, Masahiro
    Innis, Robert B.
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (11) : 1188 - 1189
  • [9] Image-derived input function with factor analysis and a priori information
    Simoncic, Urban
    Zanotti-Fregonara, Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [10] Image-derived input function with factor analysis and a priori information
    Simoncic, Urban
    Zanotti-Fregonara, Paolo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55