Flow modeling in a novel non-perfusion conical bioreactor

被引:32
作者
Singh, Harmeet [1 ]
Ang, Eng Seng [1 ]
Lim, T. T. [1 ]
Hutmacher, Dietmar W. [1 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Orthopaed Surg, Div Bioengn, Singapore 119260, Singapore
关键词
bioreactor; tissue engineering; computational fluid dynamics; scaffolds; TISSUE-ENGINEERING APPLICATIONS; CIRCULAR-CYLINDER; REYNOLDS NUMBERS; LAMINAR-FLOW; VISCOUS-FLOW; CARTILAGE; SCAFFOLDS; DESIGN; FORCES; CELLS;
D O I
10.1002/bit.21327
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We have developed a bioreactor vessel design which has the advantage of simplicity and ease of assembly and disassembly, and with the appropriately determined flow rate, even allows for a scaffold to be suspended freely regardless of its weight. This article reports our experimental and numerical investicagions to evaluate the performance of a newly developed non perfusion conical bioreactor by visualizing the flow through scaffolds with 45 degrees and 90 degrees fiber lay down patterns. The experiments were conducted at the Reynolds numbers (Re) 121, 170 and 218 based on the local velocity and width of scaffolds. The flow fields were captured using short-time exposures of 60 mu m particles suspended in the bioreactor and illuminated using a thin laser sheet. The effects of scaffold fiber lay down patter and Reynolds number were obtained and correspondingly fluid dynamics (CFD) software package. The objectives of this article are twofold: to investigate the hyposthesis that there may be an insufficient exchange of medium within the interior of the scaffold when using our non-perfusion bioreactor, and second, to compare the flows within and around scaffolds of 45 degrees and 90 degrees fiber lay down patterns. It was therefore shown that fluidic transport could be achieved within scaffolds with our bioreactor design, being a non-perfusion vessel. Fluid velocities were generally same of the same or one order lower in magnitude as compared to the inlet flow velocity. Additionally, the 90 degrees fiber lay down patterns scaffold was found to allow for slightly higher fluid velocities within, as compared to the 45 degrees fiber lay down pattern scaffold. This was due to the architecture and pore arrangement of the 90 degrees fiber lay down pattern scaffold, which allows for fluid to flow directly through (channel-like flow).
引用
收藏
页码:1291 / 1299
页数:9
相关论文
共 36 条
[1]   STEADY SEPARATED FLOW PAST A CIRCULAR CYLINDER AT LARGE REYNOLDS NUMBERS [J].
ACRIVOS, A ;
SNOWDEN, DD ;
GROVE, AS ;
PETERSEN, EE .
JOURNAL OF FLUID MECHANICS, 1965, 21 :737-&
[2]   Cell differentiation by mechanical stress [J].
Altman, GH ;
Horan, RL ;
Martin, I ;
Farhadi, J ;
Stark, PRH ;
Volloch, V ;
Richmond, JC ;
Vunjak-Novakovic, G ;
Kaplan, DL .
FASEB JOURNAL, 2001, 15 (14) :270-+
[3]   Design of a flow perfusion bioreactor system for bone tissue-engineering applications [J].
Bancroft, GN ;
Sikavitsas, VI ;
Mikos, AG .
TISSUE ENGINEERING, 2003, 9 (03) :549-554
[4]   INVESTIGATION OF FLOW AROUND RECTANGULAR CYLINDERS [J].
BEARMAN, PW ;
TRUEMAN, DM .
AERONAUTICAL QUARTERLY, 1972, 23 (AUG) :229-&
[5]   Bioreactors for tissue engineering: Focus on mechanical constraints. A comparative review [J].
Bilodeau, Katia ;
Mantovani, Diego .
TISSUE ENGINEERING, 2006, 12 (08) :2367-2383
[7]   EXPERIMENTAL-DETERMINATION OF MAIN FEATURES OF VISCOUS-FLOW IN WAKE OF A CIRCULAR-CYLINDER IN UNIFORM TRANSLATION .1. STEADY FLOW [J].
COUTANCEAU, M ;
BOUARD, R .
JOURNAL OF FLUID MECHANICS, 1977, 79 (FEB22) :231-+
[8]   A NUMERICAL STUDY OF STEADY VISCOUS-FLOW PAST A CIRCULAR-CYLINDER [J].
FORNBERG, B .
JOURNAL OF FLUID MECHANICS, 1980, 98 (JUN) :819-855
[9]  
Freed L.E., 2000, PRINCIPLES TISSUE EN, P143
[10]   Cartilage tissue remodeling in response to mechanical forces [J].
Grodzinsky, AJ ;
Levenston, ME ;
Jin, M ;
Frank, EH .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2000, 2 :691-+