Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometry

被引:85
作者
Barnett, DA
Ells, B
Guevremont, R [1 ]
机构
[1] Natl Res Council Canada, Inst Natl Measurement Stand, Ottawa, ON K1A 0R6, Canada
[2] PE Sciex, Concord, ON, Canada
[3] Chatham Coll, Div Sci, Pittsburgh, PA USA
关键词
D O I
10.1016/S1044-0305(00)00187-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Effects of carrier gas type (N-2, O-2, CO2, N2O, and SF6) on changes in the ratio of high- to low-field ion mobility, K-h/K, of cesium, gramicidin S, tetrahexylammonium, heptadecanoic acid, and aspartic acid in fields of up to 67 Td are presented. The theory of the mobility of ions at high E/N in different gases is discussed. Plots of K-h/K as a function of the ionic energy parameter, E/N, for the five ions in each of the gases were derived from experimental data collected using a high-held asymmetric waveform ion mobility spectrometer. The change in the ratio of high- to low-field ion mobility of cesium in carrier gases of O-2 and N-2 showed excellent agreement with literature values. The behavior of cesium in O-2 and N-2 is used to illustrate that the ratio K-h/K as a function of effective temperature is invariant with gas type as long as the well depth of the interaction potential significantly exceeds thermal energy. From these results, it appears that the well depth of the interaction potential of the heavier ions studied here, including gramicidin S, tetrahexylammonium, and heptadecanoic acid, with bath gases such as N-2 and O-2 is shallow relative to thermal energy. (J Am Soc Mass Spectrom 2000, 11, 1125-1133) (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:1125 / 1133
页数:9
相关论文
共 31 条
[1]  
Barnett DA, 2000, J MASS SPECTROM, V35, P976, DOI 10.1002/1096-9888(200008)35:8<976::AID-JMS25>3.0.CO
[2]  
2-Q
[3]   Determination of parts-per-trillion levels of chlorate, bromate, and iodate by electrospray ionization/high-field asymmetric waveform ion mobility spectrometry/mass spectrometry [J].
Barnett, DA ;
Guevremont, R ;
Purves, RW .
APPLIED SPECTROSCOPY, 1999, 53 (11) :1367-1374
[4]   Separation of leucine and isoleucine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Barnett, DA ;
Ells, B ;
Guevremont, R ;
Purves, RW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1279-1284
[5]   Isotope separation using high-field asymmetric waveform ion mobility spectrometry [J].
Barnett, DA ;
Purves, RW ;
Guevremont, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 450 (01) :179-185
[6]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[7]  
CARNAHAN BL, 1995, Patent No. 5420424
[8]  
Ellis H. W., 1978, Atomic Data and Nuclear Data Tables, V22, P179, DOI 10.1016/0092-640X(78)90014-1
[9]  
Ellis H. W., 1976, Atomic Data and Nuclear Data Tables, V17, P177, DOI 10.1016/0092-640X(76)90001-2
[10]   TRANSPORT-PROPERTIES OF GASEOUS-IONS OVER A WIDE ENERGY-RANGE .3. [J].
ELLIS, HW ;
THACKSTON, MG ;
MCDANIEL, EW ;
MASON, EA .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1984, 31 (01) :113-151