A New Technique Implemented in Synchronous Reference Frame for DVR Control Under Severe Sag and Swell Conditions

被引:13
作者
Al-Gahtani, Saad F. [1 ]
Barnawi, Abdulwasa B. [1 ]
Azazi, Haitham Zaki [2 ]
Irshad, Shaik M. [1 ]
Bhutto, Javed K. [1 ]
Majahar, H. M. [1 ]
Salem, Elbarbary Z. M. [1 ,3 ]
机构
[1] King Khalid Univ, Dept Elect Engn, Coll Engn, Abha 61421, Saudi Arabia
[2] Menou Univ, Dept Elect Engn, Fac Engn, Shibin Al Kawm 32511, Egypt
[3] Kafrelsheikh Univ, Dept Elect Engn, Fac Engn, Kafr El Shaikh 33516, Egypt
关键词
Voltage control; Power quality; Voltage fluctuations; Power system dynamics; Power system stability; Control systems; Mathematical models; Balance and unbalanced load; dynamic voltage restorer (DVR); instantaneous space vector; synchronous stationary frame (DQ) theory; voltage sag; voltage swell; DYNAMIC VOLTAGE RESTORER;
D O I
10.1109/ACCESS.2022.3151919
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Nowadays, power quality under the excessive implementation of power electronics devices is quite challenging issue. The compensation of non-sinusoidal; reactive and harmonic; components is the main role for power quality devices which highly depend on the robustness of the control system. Some common control systems are implemented using Synchronous Stationary Frame (DQ) theory. This paper proposes a new version of DQ control technique to control dynamic voltage restorer under severe transient voltage conditions. The power system network with the new DQ control technique is studied and analyzed under different scenarios to compensate for severe balanced and unbalanced voltage sags and swells. This new scheme is based on extraction of positive sequence components to implement the control algorithm. A mathematical model of the dynamic voltage restorer (DVR), hysteresis voltage control, converter controller model, new DQ scheme with complete system equations are carried out and verified using Simulink / MATLAB. The proposed system is validated experimentally using DSpace 1104 based laboratory system. The obtained results of the proposed compensation algorithm are compared with the results obtained from the traditional DQ method. Simulation and experimental results are correlated and show effectiveness of the proposed DQ control scheme.
引用
收藏
页码:25565 / 25579
页数:15
相关论文
共 46 条
[1]   Power Quality Improvement Using Dynamic Voltage Restorer [J].
Abas, Naeem ;
Dilshad, Saad ;
Khalid, Adnan ;
Saleem, Muhammad Shoaib ;
Khan, Nasrullah .
IEEE ACCESS, 2020, 8 :164325-164339
[2]  
Abdulazeez Saud N., 2019, 2019 2nd International Conference on Electrical, Communication, Computer, Power and Control Engineering (ICECCPCE), P165, DOI 10.1109/ICECCPCE46549.2019.203767
[3]  
Afonso J., 2000, IEEE Industrial Electronics Society Newsletter, V47, P5, DOI DOI 10.1037/0022-3514.79.1.5,ISSN
[4]   A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges [J].
Alhelou, Hassan Haes ;
Hamedani-Golshan, Mohamad Esmail ;
Njenda, Takawira Cuthbert ;
Siano, Pierluigi .
ENERGIES, 2019, 12 (04)
[5]   Novel Sag Detection Method for Line-Interactive Dynamic Voltage Restorer [J].
Bae, B. ;
Jeong, J. ;
Lee, J. ;
Han, B. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (02) :1210-1211
[6]   Reparation of voltage disturbance using PR controller-based DVR in Modern power systems [J].
Danalakshmi, D. ;
Prathiba, S. ;
Ettappan, M. ;
Krishna, D. Mohan .
PRODUCTION ENGINEERING ARCHIVES, 2021, 27 (01) :16-29
[7]   Cascaded Open-End Winding Transformer Based DVR [J].
de Almeida Carlos, Gregory Arthur ;
Jacobina, Cursino Brandao ;
Ramos Agra Mello, Joao Paulo ;
dos Santos, Euzeli Cipriano, Jr. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (02) :1490-1501
[8]  
Deckmann SM, 2002, INT C HARMON QUAL PO, P144
[9]  
El Sayed Noura G., 2019, 2019 7th International Japan-Africa Conference on Electronics, Communications and Computations (JAC-ECC). Proceedings, P210, DOI 10.1109/JAC-ECC48896.2019.9051252
[10]   Enhanced DVR Control System Based on the Harris Hawks Optimization Algorithm [J].
Elkady, Zeinab ;
Abdel-Rahim, Naser ;
Mansour, Ahmed A. ;
Bendary, Fahmy M. .
IEEE ACCESS, 2020, 8 :177721-177733