Accuracy of a Portable Multisensor Body Monitor for Predicting Resting Energy Expenditure in Older People: A Comparison with Indirect Calorimetry

被引:18
作者
Heiermann, Stefanie [1 ]
Hedayati, Kerstin Khalaj [1 ]
Mueller, Manfred J. [2 ]
Dittmar, Manuela [1 ]
机构
[1] Univ Kiel, Inst Zool, Dept Human Biol, DE-24118 Kiel, Germany
[2] Univ Kiel, Inst Human Nutr & Food Sci, DE-24118 Kiel, Germany
关键词
Accelerometry; Motion sensor; Validity; Indirect calorimetry; Resting energy expenditure; SYMPATHETIC SKIN-RESPONSE; METABOLIC-RATE; PHYSICAL-ACTIVITY; VALIDATION; ARMBAND; VARIABILITY; OVERNIGHT; AGREEMENT; HUMANS; COST;
D O I
10.1159/000322109
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Accurate and comfortable methods are needed to determine resting energy expenditure (REE) in older people who are characterized by a lowered metabolic rate. The portable SenseWear (R) armband (SWA) body monitor, worn on the right upper arm, can easily be used by this age group in an ambulatory manner. Objective: The purpose of this study was to evaluate the reliability and accuracy of the SWA armband in determining REE in healthy, normal-weight older people. Methods: Participants were 49 older, community-dwelling volunteers aged 60-87 years. Reliability was tested in all subjects. Accuracy was analyzed in 32 subjects by comparing REE estimated by SWA against REE measured by indirect calorimetry as a criterion method. Data were simultaneously and continuously recorded for 20 min in the morning. In the same subjects, REE determined by SWA from night recording was evaluated for accuracy against indirect calorimetry. The agreement between methods was assessed by the Bland-Altman procedure. Results: (1) REE measured by SWA was reliable when comparing 2 consecutive measurements (typical error: 1.9%). (2) REE calculated from morning recording (1,543 +/- 181 kcal/24 h) was higher than REE from night recording (1,564 +/- 192 kcal/24 h; p = 0.018). (3) Compared with REE by indirect calorimetry (1,377 +/- 228 kcal/24 h) for accuracy, the SWA overestimated mean REE in the older people by 12 and 14%, respectively, for morning and night recording (each p < 0.001). Conclusions: The SWA provides a reliable estimate of REE in healthy older subjects and has the advantage of easy handling. The 20-min recording time, which was recommended by the manufacturer, can be applied. However, the SWA overestimates REE in this group, possibly due to age-related changes in skin conductance and thermoregulation, both being measured by sensors of the SWA armband. This requires improving the SWA by developing better fitting algorithms for predicting REE in older people. Copyright (C) 2011 S. Karger AG, Basel
引用
收藏
页码:473 / 479
页数:7
相关论文
共 50 条
  • [31] Measurement of Resting Energy Expenditure with Indirect Calorimetry and Predictive Equations in Healthy Young Adults: A Cross-sectional Study
    Soni, Harsha
    Kacker, Sudhanshu
    Saboo, Neha
    Buttar, Karampreet
    Jitender
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (07) : CC09 - CC12
  • [32] Longitudinal Measurements of Resting Energy Expenditure by Indirect Calorimetry in Healthy Term Infants during the First 2 Months of Life
    Verma, Sourabh
    Bailey, Sean M.
    Mally, Pradeep V.
    Howell, Heather B.
    AMERICAN JOURNAL OF PERINATOLOGY, 2019, 36 (09) : 918 - 923
  • [33] Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry
    Sundstrom, Martin
    Mehrabi, Mahboubeh
    Tjader, Inga
    Rooyackers, Olav
    Hammarqvist, Folke
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2017, 41 (06) : 976 - 980
  • [34] Evaluating steady-state resting energy expenditure using indirect calorimetry in adults with overweight and obesity
    Popp, C. J.
    Butler, M.
    Curran, M.
    Illiano, P.
    Sevick, M. A.
    St-Jules, D. E.
    CLINICAL NUTRITION, 2020, 39 (07) : 2220 - 2226
  • [35] Resting energy expenditure in children in a pediatric intensive care unit: comparison of Harris-Benedict and Talbot predictions with indirect calorimetry values
    Coss-Bu, JA
    Jefferson, LS
    Walding, D
    David, Y
    Smith, EO
    Klish, WJ
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 67 (01) : 74 - 80
  • [36] Resting energy expenditure of morbidly obese patients using indirect calorimetry: a systematic review
    Kee, A. -L.
    Isenring, E.
    Hickman, I.
    Vivanti, A.
    OBESITY REVIEWS, 2012, 13 (09) : 753 - 765
  • [37] Reading and Listening to Music Increase Resting Energy Expenditure during an Indirect Calorimetry Test
    Snell, Blaire
    Fullmer, Susan
    Eggett, Dennis L.
    JOURNAL OF THE ACADEMY OF NUTRITION AND DIETETICS, 2014, 114 (12) : 1939 - 1942
  • [38] Analysis of energy expenditure in adults with cystic fibrosis: Comparison of indirect calorimetry and prediction equations
    Olveira-Fuster, Casilda
    Olveira-Fuster, Gabriel
    Dorado Galindo, Antonio
    Padilla Galo, Alicia
    Merino Verdugo, Julio
    Miralles Lozano, Francisco
    ARCHIVOS DE BRONCONEUMOLOGIA, 2007, 43 (07): : 366 - 372
  • [39] Evaluation of a non-invasive multisensor accelerometer for calculating energy expenditure in ventilated intensive care patients compared to indirect calorimetry and predictive equations
    Krueger, Janine
    Kraft, Matthias
    Gruendling, Matthias
    Friesecke, Sigrun
    Gaertner, Simone
    Vogt, Lena J.
    Schueler, Nicole
    Steveling, Antje
    Lerch, Markus M.
    Aghdassi, Ali A.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 1009 - 1017
  • [40] Approximate Time to Steady-state Resting Energy Expenditure Using Indirect Calorimetry in Young, Healthy Adults
    Popp, Collin J.
    Tisch, Jocelyn J.
    Sakarcan, Kenan E.
    Bridges, William C.
    Jesch, Elliot D.
    FRONTIERS IN NUTRITION, 2016, 3