Accuracy of a Portable Multisensor Body Monitor for Predicting Resting Energy Expenditure in Older People: A Comparison with Indirect Calorimetry

被引:18
作者
Heiermann, Stefanie [1 ]
Hedayati, Kerstin Khalaj [1 ]
Mueller, Manfred J. [2 ]
Dittmar, Manuela [1 ]
机构
[1] Univ Kiel, Inst Zool, Dept Human Biol, DE-24118 Kiel, Germany
[2] Univ Kiel, Inst Human Nutr & Food Sci, DE-24118 Kiel, Germany
关键词
Accelerometry; Motion sensor; Validity; Indirect calorimetry; Resting energy expenditure; SYMPATHETIC SKIN-RESPONSE; METABOLIC-RATE; PHYSICAL-ACTIVITY; VALIDATION; ARMBAND; VARIABILITY; OVERNIGHT; AGREEMENT; HUMANS; COST;
D O I
10.1159/000322109
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Accurate and comfortable methods are needed to determine resting energy expenditure (REE) in older people who are characterized by a lowered metabolic rate. The portable SenseWear (R) armband (SWA) body monitor, worn on the right upper arm, can easily be used by this age group in an ambulatory manner. Objective: The purpose of this study was to evaluate the reliability and accuracy of the SWA armband in determining REE in healthy, normal-weight older people. Methods: Participants were 49 older, community-dwelling volunteers aged 60-87 years. Reliability was tested in all subjects. Accuracy was analyzed in 32 subjects by comparing REE estimated by SWA against REE measured by indirect calorimetry as a criterion method. Data were simultaneously and continuously recorded for 20 min in the morning. In the same subjects, REE determined by SWA from night recording was evaluated for accuracy against indirect calorimetry. The agreement between methods was assessed by the Bland-Altman procedure. Results: (1) REE measured by SWA was reliable when comparing 2 consecutive measurements (typical error: 1.9%). (2) REE calculated from morning recording (1,543 +/- 181 kcal/24 h) was higher than REE from night recording (1,564 +/- 192 kcal/24 h; p = 0.018). (3) Compared with REE by indirect calorimetry (1,377 +/- 228 kcal/24 h) for accuracy, the SWA overestimated mean REE in the older people by 12 and 14%, respectively, for morning and night recording (each p < 0.001). Conclusions: The SWA provides a reliable estimate of REE in healthy older subjects and has the advantage of easy handling. The 20-min recording time, which was recommended by the manufacturer, can be applied. However, the SWA overestimates REE in this group, possibly due to age-related changes in skin conductance and thermoregulation, both being measured by sensors of the SWA armband. This requires improving the SWA by developing better fitting algorithms for predicting REE in older people. Copyright (C) 2011 S. Karger AG, Basel
引用
收藏
页码:473 / 479
页数:7
相关论文
共 50 条
  • [21] External Validation with Accuracy Confounders of VCO2-Derived Predicted Energy Expenditure Compared to Resting Energy Expenditure Measured by Indirect Calorimetry in Mechanically Ventilated Children
    Briassoulis, Panagiotis
    Ilia, Stavroula
    Briassouli, Efrossini
    Briassoulis, George
    NUTRIENTS, 2022, 14 (19)
  • [22] Accuracy of predictive equations for the measurement of resting energy expenditure in older subjects
    Siervo, M.
    Bertoli, S.
    Battezzati, A.
    Wells, J. C.
    Lara, J.
    Ferraris, C.
    Tagliabue, A.
    CLINICAL NUTRITION, 2014, 33 (04) : 613 - 619
  • [23] Minimum Time to Achieve the Steady State and Optimum Abbreviated Period to Estimate the Resting Energy Expenditure by Indirect Calorimetry in Healthy Young Adults
    Borges, Juliano H.
    Langer, Raquel D.
    Cirolini, Vagner X.
    Pascoa, Mauro A.
    Guerra-Junior, Gil
    Goncalves, Ezequiel M.
    NUTRITION IN CLINICAL PRACTICE, 2016, 31 (03) : 349 - 354
  • [24] Resting energy expenditure in patients with liver cirrhosis: Indirect calorimetry vs. predictive equations
    Wang, Wen
    Yang, Tingting
    Li, Ning
    Luo, Qiankun
    Qin, Tao
    Tian, Mengxing
    Jin, Xin
    Lei, Lei
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2024, 33 (04) : 545 - 553
  • [25] Accuracy of the MedGem® portable indirect calorimeter for measuring resting energy expenditure in adults with class II or III obesity
    Purcell, Sarah A.
    Johnson-Stoklossa, Carlene
    Braga Tibaes, Jenneffer Rayane
    Frankish, Alena
    Elliott, Sarah A.
    Padwal, Raj
    Prado, Carla M.
    CLINICAL NUTRITION ESPEN, 2020, 40 : 408 - 411
  • [26] Accuracy of Abbreviated Indirect Calorimetry Protocols for Energy Expenditure Measurement in Critically Ill Children
    Smallwood, Craig D.
    Mehta, Nilesh M.
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2012, 36 (06) : 693 - 699
  • [27] Resting Energy Expenditure per Lean Body Mass Determined by Indirect Calorimetry and Bioelectrical Impedance Analysis in Cats
    Center, S. A.
    Warner, K. L.
    Randolph, J. F.
    Wakshlag, J. J.
    Sunvold, G. D.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (06) : 1341 - 1350
  • [28] Methods for data analysis of resting energy expenditure measured using indirect calorimetry
    Borges, Juliano H.
    Guerra-Junior, Gil
    Goncalves, Ezequiel M.
    NUTRITION, 2019, 59 : 44 - 49
  • [29] Energy Expenditure in Adolescents With Cerebral Palsy: Comparison of the SenseWear Armband and Indirect Calorimetry
    Koehler, Karsten
    Abel, Thomas
    Wallmann-Sperlich, Birgit
    Dreuscher, Annika
    Anneken, Volker
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2015, 12 (04) : 540 - 545
  • [30] Body composition affects the accuracy of predictive equations to estimate resting energy expenditure in older adults: An exploratory study
    Batista, Lais Duarte
    Neto, Joao Valentini
    de Franca, Natasha Aparecida Grande
    Ribeiro, Sandra Maria Lima
    Fisberg, Regina Mara
    CLINICAL NUTRITION ESPEN, 2023, 53 : 80 - 86