Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry

被引:71
作者
Belov, Arseniy M. [1 ]
Viner, Rosa [2 ]
Santos, Marcia R. [3 ]
Horn, David M. [2 ]
Bern, Marshall [4 ]
Karger, Barry L. [1 ]
Ivanov, Alexander R. [1 ]
机构
[1] Northeastern Univ, Barnett Inst Chem & Biol Anal, Boston, MA 02115 USA
[2] Thermo Fisher Sci, San Jose, CA 95134 USA
[3] SCIEX Ltd, Brea, CA 92821 USA
[4] Prot Metr, San Carlos, CA 94070 USA
关键词
Capillary zone electrophoresis; Sheathless CZE-MS; Native mass spectrometry; Top-down mass spectrometry; Ultra-low flow separations; Protein complexes; Ribosome; Specialized ribosomes; Proteoform; Aggregation of biopharmaceutical proteins; FIELD-FLOW FRACTIONATION; ESCHERICHIA-COLI; RIBOSOMAL-PROTEINS; YEAST ENOLASE; GAS-PHASE; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; STRUCTURAL BASIS; SEPARATION; MS;
D O I
10.1007/s13361-017-1781-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes).
引用
收藏
页码:2614 / 2634
页数:21
相关论文
共 86 条
  • [41] Mass Spectrometric Analysis of Intact Human Monoclonal Antibody Aggregates Fractionated by Size-Exclusion Chromatography
    Kukrer, Basak
    Filipe, Vasco
    van Duijn, Esther
    Kasper, Piotr T.
    Vreeken, Rob J.
    Heck, Albert J. R.
    Jiskoot, Wim
    [J]. PHARMACEUTICAL RESEARCH, 2010, 27 (10) : 2197 - 2204
  • [42] CAPILLARY ZONE ELECTROPHORESIS OF PROTEINS IN UNTREATED FUSED-SILICA TUBING
    LAUER, HH
    MCMANIGILL, D
    [J]. ANALYTICAL CHEMISTRY, 1986, 58 (01) : 166 - 170
  • [43] CRYSTAL-STRUCTURE OF ENOLASE INDICATES THAT ENOLASE AND PYRUVATE-KINASE EVOLVED FROM A COMMON ANCESTOR
    LEBIODA, L
    STEC, B
    [J]. NATURE, 1988, 333 (6174) : 683 - 686
  • [44] Native Mass Spectrometry: What is in the Name?
    Leney, Aneika C.
    Heck, Albert J. R.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (01) : 5 - 13
  • [45] The three zinc-containing alcohol dehydrogenases from baker's yeast, Saccharomyces cerevisiae
    Leskovac, V
    Trivic, S
    Pericin, D
    [J]. FEMS YEAST RESEARCH, 2002, 2 (04) : 481 - 494
  • [46] Revealing Ligand Binding Sites and Quantifying Subunit Variants of Noncovalent Protein Complexes in a Single Native Top-Down FTICR MS Experiment
    Li, Huilin
    Wongkongkathep, Piriya
    Van Orden, Steve L.
    Loo, Rachel R. Ogorzalek
    Loo, Joseph A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (12) : 2060 - 2068
  • [47] Li S., 2015, MOL CELL PROTEOM
  • [48] Separation and detection of intact noncovalent protein complexes from mixtures by on-line capillary isoelectric focusing-mass spectrometry
    Martinovic, S
    Berger, SJ
    Pasa-Tolic, L
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5356 - 5360
  • [49] Twenty years of interface development for capillary electrophoresis-electrospray ionization-mass spectrometry
    Maxwell, E. Jane
    Chen, David D. Y.
    [J]. ANALYTICA CHIMICA ACTA, 2008, 627 (01) : 25 - 33
  • [50] Decoupling CE and ESI for a more robust interface with MS
    Maxwell, E. Jane
    Zhong, Xuefei
    Zhang, Hong
    van Zeijl, Nikita
    Chen, David D. Y.
    [J]. ELECTROPHORESIS, 2010, 31 (07) : 1130 - 1137