Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center

被引:124
作者
Gibbons, Raymond J. [1 ]
Miller, Todd D. [1 ]
Hodge, David [2 ]
Urban, Lynn [2 ]
Araoz, Philip A. [3 ]
Pellikka, Patricia [1 ]
McCully, Robert B. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Dept Med, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biostat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Radiol, Mayo Fdn, Rochester, MN 55905 USA
关键词
D O I
10.1016/j.jacc.2007.10.064
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to apply published appropriateness criteria for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) in a single academic medical center. Background The American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC) have developed appropriateness criteria for stress SPECT MPI to address concern about the growth in cardiac imaging studies. Methods We retrospectively examined 284 patients who underwent stress SPECT MPI and 298 patients who underwent stress echocardiography before publication of these criteria. Results The overall level of agreement in characterizing appropriateness between 2 experienced cardiovascular nurse abstractors was modest (kappa = 0.56), but noticeably poorer (kappa = 0.27) for patients with previous SPECT or echo studies. Similar percentages of each imaging modality were assigned to the 3 appropriateness categories: 64% of stress SPECT and 64% of stress echo studies were classified appropriate; 11% of stress SPECT and 9% of stress echo were of uncertain appropriateness; and 14% of stress SPECT and 18% of stress echo were inappropriate. Of the inappropriate studies, 88% were performed for I of 4 indications. Approximately 10% of the patients were unclassifiable. Conclusions Application of existing SPECT MPI appropriateness criteria is demanding and requires an established database or detailed data collection, as well as a number of assumptions. Fourteen percent of stress SPECT studies and 18% of stress echo studies were performed for inappropriate reasons. Quality improvement efforts directed at reducing the number of these inappropriate studies may improve efficiency in the health care system.
引用
收藏
页码:1283 / 1289
页数:7
相关论文
共 17 条
  • [11] The new era of medical imaging - Progress and pitfalls
    Iglehart, JK
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2006, 354 (26) : 2822 - 2828
  • [12] Institute of Medicine, 2001, CROSSING QUALITY CHA, DOI [10.17226/10027, DOI 10.17226/10027]
  • [13] Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001
    Lucas, FL
    DeLorenzo, MA
    Siewers, AE
    Wennberg, DE
    [J]. CIRCULATION, 2006, 113 (03) : 374 - 379
  • [14] Outcome after abnormal exercise echocardiography for patients with good exercise capacity - Prognostic importance of the extent and severity of exercise-related left ventricular dysfunction
    McCully, RB
    Roger, VL
    Mahoney, DW
    Burger, KN
    Click, RL
    Seward, JB
    Pellikka, PA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (08) : 1345 - 1352
  • [15] ACCF proposed method for evaluating the appropriateness of cardiovascular imaging
    Patel, MR
    Spertus, JA
    Brindis, RG
    Hendel, RC
    Douglas, PS
    Peterson, ED
    Wolk, MJ
    Allen, JM
    Raskin, IE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) : 1606 - 1613
  • [16] Utility of myocardial perfusion imaging in patients with low-risk treadmill scores
    Poornima, IG
    Miller, TD
    Christian, TF
    Hodge, DO
    Bailey, KR
    Gibbons, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (02) : 194 - 199
  • [17] RISK ASSESSMENT TOOL