Comparison of different caries detectors for approximal caries detection

被引:13
作者
Bozdemir, Esin [1 ]
Aktan, Ali Murat [2 ]
Ozsevik, Abdulsemih [3 ]
Kararslan, Emine Sirin [4 ]
Ciftci, Mehmet Ertugrul [5 ]
Cebe, Mehmet Ata [6 ]
机构
[1] Suleyman Demirel Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Isparta, Turkey
[2] Usak Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Usak, Turkey
[3] Gaziantep Univ, Fac Dent, Dept Restorat Dent, Gaziantep, Turkey
[4] Gaziosmanpasa Univ, Fac Dent, Dept Restorat Dent, Tokat, Turkey
[5] Akdeniz Univ, Fac Dent, Dept Dentomaxillofacial Radiol, AD Kampus, TR-07058 Antalya, Turkey
[6] Abant Izzet Baysal Univ, Fac Dent, Dept Restorat Dent, Bolu, Turkey
关键词
approximal caries; bitewing examination; histological examination; laser fluorescence device; light-emitting diode device; LASER FLUORESCENCE DEVICE; IN-VIVO PERFORMANCE; OCCLUSAL CARIES; PRIMARY TEETH; PERMANENT;
D O I
10.1016/j.jds.2016.03.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Detection of approximal caries may be difficult using conventional methods including visual inspection (VI) and radiography. The purpose of this in vitro research was to evaluate the efficiency of light-emitting diode (LED) and laser fluorescence (LF) devices, and radiographic and visual examination in approximal caries diagnosis. Materials and methods: One hundred and fifty-six approximal regions were evaluated. All approximal regions were investigated using LED and LF tools after radiography and VI were performed. Histological evaluation of teeth was performed using stereomicroscopy. The area under the receiver operating characteristic curve and accuracy, specificity, sensitivity values calculated regarding approximal caries diagnose. Results: The specificity of the bitewing examination was higher for both T1 and T2 thresholds (0.97 and 0.99, respectively), and the LF device showed better sensitivity at each threshold compared with the other devices used for caries diagnosis (0.94 at T1 and 0.79 at T2). The receiver operating characteristic curves presented that the LF device was more successful than the other techniques at T1 threshold and VI was better than the other caries detection methods at T2 threshold. The kappa values for interobserver agreements were 0.43 (LF pen), 0.33 (LED device), 0.55 (VI), and 0.75 (bitewing examination). Conclusion: The ability of bitewing radiography to identify sound surfaces was better than that of the other methods. The LF device was the most sensitive tool for detecting approximal surfaces with caries, followed by the LED device. Copyright (C) 2016, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
[41]   Association Between Visual Inspection, Caries Activity Status, and Radiography with Treatment Decisions on Approximal Caries in Primary Molars [J].
Freitas, Licia Aguilar ;
Botti Rodrigues Santos, Maria Teresa ;
Guare, Renata Oliveira ;
Lussi, Adrian ;
Diniz, Michele Baffi .
PEDIATRIC DENTISTRY, 2016, 38 (02) :140-147
[42]   Traditional and novel methods for occlusal caries detection: performance on primary teeth [J].
Souza, J. F. ;
Boldieri, T. ;
Diniz, M. B. ;
Rodrigues, J. A. ;
Lussi, A. ;
Cordeiro, R. C. L. .
LASERS IN MEDICAL SCIENCE, 2013, 28 (01) :287-295
[43]   In vitro ability of a laser fluorescence device in quantifying approximal caries lesions in primary molars [J].
Celiberti, P. ;
Leamari, V. M. ;
Imparato, J. C. P. ;
Braga, M. M. ;
Mendes, F. M. .
JOURNAL OF DENTISTRY, 2010, 38 (08) :666-670
[44]   Changes in the Treatment Concept for Approximal Caries from 1983 to 2009 in Norway [J].
Vidnes-Kopperud, S. ;
Tveit, A. B. ;
Espelid, I. .
CARIES RESEARCH, 2011, 45 (02) :113-120
[45]   In vitro visual and visible light transillumination methods for detection of natural non-cavitated approximal caries [J].
Abogazalah, N. ;
Eckert, G. J. ;
Ando, Masatoshi .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (03) :1287-1294
[46]   Validity of caries detection methods under epidemiological setting [J].
da Silva, Renato Pereira ;
Assaf, Andrea Videira ;
Pereira, Stela Marcia ;
Mialhe, Fabio Luiz ;
Bovi Ambrosano, Glaucia Maria ;
Meneghim, Marcelo de Castro ;
Pereira, Antonio Carlos .
AMERICAN JOURNAL OF DENTISTRY, 2011, 24 (06) :363-366
[47]   In Vivo Performance of Two Devices for Occlusal Caries Detection [J].
Bozdemir, Esin ;
Karaarslan, Emine Sirin ;
Ozsevik, A. Semih ;
Cebe, M. Ata ;
Aktan, Ali Murat .
PHOTOMEDICINE AND LASER SURGERY, 2013, 31 (07) :322-327
[48]   In vitro visual and visible light transillumination methods for detection of natural non-cavitated approximal caries [J].
N. Abogazalah ;
G. J. Eckert ;
Masatoshi Ando .
Clinical Oral Investigations, 2019, 23 :1287-1294
[49]   OXIS Contacts and Approximal Caries in Preschool Children: A Prospective Cohort Study [J].
Kirthiga, M. ;
Muthu, M. S. ;
Kayalvizhi, Gurusamy ;
Mathur, Vijay Prakash ;
Jayakumar, Naveenkumar ;
Praveen, R. .
CARIES RESEARCH, 2023, 57 (02) :133-140
[50]   Approximal caries increment: a three-year longitudinal radiographic study [J].
Poorterman, JHG ;
Aartman, IHA ;
Kieft, JA ;
Kalsbeek, H .
INTERNATIONAL DENTAL JOURNAL, 2003, 53 (05) :269-274