Comparison of different caries detectors for approximal caries detection

被引:13
作者
Bozdemir, Esin [1 ]
Aktan, Ali Murat [2 ]
Ozsevik, Abdulsemih [3 ]
Kararslan, Emine Sirin [4 ]
Ciftci, Mehmet Ertugrul [5 ]
Cebe, Mehmet Ata [6 ]
机构
[1] Suleyman Demirel Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Isparta, Turkey
[2] Usak Univ, Fac Dent, Dept Dentomaxillofacial Radiol, Usak, Turkey
[3] Gaziantep Univ, Fac Dent, Dept Restorat Dent, Gaziantep, Turkey
[4] Gaziosmanpasa Univ, Fac Dent, Dept Restorat Dent, Tokat, Turkey
[5] Akdeniz Univ, Fac Dent, Dept Dentomaxillofacial Radiol, AD Kampus, TR-07058 Antalya, Turkey
[6] Abant Izzet Baysal Univ, Fac Dent, Dept Restorat Dent, Bolu, Turkey
关键词
approximal caries; bitewing examination; histological examination; laser fluorescence device; light-emitting diode device; LASER FLUORESCENCE DEVICE; IN-VIVO PERFORMANCE; OCCLUSAL CARIES; PRIMARY TEETH; PERMANENT;
D O I
10.1016/j.jds.2016.03.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Detection of approximal caries may be difficult using conventional methods including visual inspection (VI) and radiography. The purpose of this in vitro research was to evaluate the efficiency of light-emitting diode (LED) and laser fluorescence (LF) devices, and radiographic and visual examination in approximal caries diagnosis. Materials and methods: One hundred and fifty-six approximal regions were evaluated. All approximal regions were investigated using LED and LF tools after radiography and VI were performed. Histological evaluation of teeth was performed using stereomicroscopy. The area under the receiver operating characteristic curve and accuracy, specificity, sensitivity values calculated regarding approximal caries diagnose. Results: The specificity of the bitewing examination was higher for both T1 and T2 thresholds (0.97 and 0.99, respectively), and the LF device showed better sensitivity at each threshold compared with the other devices used for caries diagnosis (0.94 at T1 and 0.79 at T2). The receiver operating characteristic curves presented that the LF device was more successful than the other techniques at T1 threshold and VI was better than the other caries detection methods at T2 threshold. The kappa values for interobserver agreements were 0.43 (LF pen), 0.33 (LED device), 0.55 (VI), and 0.75 (bitewing examination). Conclusion: The ability of bitewing radiography to identify sound surfaces was better than that of the other methods. The LF device was the most sensitive tool for detecting approximal surfaces with caries, followed by the LED device. Copyright (C) 2016, Association for Dental Sciences of the Republic of China. Published by Elsevier Taiwan LLC. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
[21]   A clinical study of a laser fluorescence device for the detection of approximal caries in primary molars [J].
Chen, Jianghao ;
Qin, Man ;
Ma, Wenli ;
Ge, Lihong .
INTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRY, 2012, 22 (02) :132-138
[22]   The Effect of Fissure Sealants on the Values of Two Different Caries Detection Devices [J].
Hastar, Esin ;
Yildiz, Esma ;
Aktan, Ali Murat .
PHOTOMEDICINE AND LASER SURGERY, 2012, 30 (12) :683-687
[23]   Comparison of visual inspection and different radiographic methods for dentin caries detection on occlusal surfaces [J].
Kuehnisch, J. ;
Ifland, S. ;
Tranaeus, S. ;
Heinrich-Weltzien, R. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (07) :452-457
[24]   In vitro comparison of digital and conventional bitewing radiographs for the detection of approximal caries in primary teeth exposed and viewed by a new wireless handheld unit [J].
Ulusu, T. ;
Bodur, H. ;
Odabas, M. E. .
DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (02) :91-94
[25]   Influence of Contact Points on the Performance of Caries Detection Methods in Approximal Surfaces of Primary Molars: An in vivo Study [J].
Ribeiro, Apoena A. ;
Purger, Flavia ;
Rodrigues, Jonas A. ;
Oliveira, Patricia R. A. ;
Lussi, Adrian ;
Monteiro, Antonio Henrique ;
Alves, Haimon D. L. ;
Assis, Joaquim T. ;
Vasconcellos, Adalberto B. .
CARIES RESEARCH, 2015, 49 (02) :99-108
[26]   Pen-type laser fluorescence device versus bitewing radiographs for caries detection on approximal surfaces [J].
Bizhang, M. ;
Wollenweber, N. ;
Singh-Huesgen, P. ;
Danesh, G. ;
Zimmer, S. .
HEAD & FACE MEDICINE, 2016, 12
[27]   In-vitro Diagnosis of Approximal Caries in Teeth Periapical Radiography with Different Exposure Parameters [J].
Altun, Oguzhan ;
Ozen, Duygu Celik ;
Dedeoglu, Numan ;
Duman, Suayip Burak ;
Eser, Gozde ;
Topaloglu, Edanur ;
Ozemre, Begum ;
Demirezer, Kardelen .
EUROPEAN JOURNAL OF THERAPEUTICS, 2023, 29 (04) :780-789
[28]   Imaging modalities to inform the detection and diagnosis of early caries [J].
Walsh, Tanya ;
Macey, Richard ;
Riley, Philip ;
Glenny, Anne-Marie ;
Schwendicke, Falk ;
Worthington, Helen, V ;
Clarkson, Janet E. ;
Ricketts, David ;
Su, Ting-Li ;
Sengupta, Anita .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2021, (03)
[29]   Adjunct methods for caries detection: A systematic review of literature [J].
Twetman, Svante ;
Axelsson, Susanna ;
Dahlen, Gunnar ;
Espelid, Ivar ;
Mejare, Ingegerd ;
Norlund, Anders ;
Tranaeus, Sofia .
ACTA ODONTOLOGICA SCANDINAVICA, 2013, 71 (3-4) :388-397
[30]   Approximal caries prevalence in Danish recruits and progression of caries in the late teens: A retrospective radiographic study [J].
Hintze, H .
CARIES RESEARCH, 2001, 35 (01) :27-35