Partly-Immersed Three Phase Hollow Fiber Liquid Phase Microextraction of Semi-Volatile Organic Compounds Combined with High Performance Liquid Chromatography

被引:0
|
作者
Lin, Hailu [1 ,2 ]
Yan, Hong [1 ]
Luo, Mingbiao [2 ]
Peng, Xuejiao [2 ]
Liu, Wei [2 ]
机构
[1] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100022, Peoples R China
[2] E China Inst Technol, Dept Appl Chem, Fuzhou 344000, Jiangxi, Peoples R China
关键词
Partly immersed liquid phase microextraction; High performance liquid chromatography; Nicotine; Sample preparation technique; Tobacco; Hollow fiber; SOLVENT MICROEXTRACTION; ORGANOCHLORINE PESTICIDES; SAMPLE PREPARATION; BIOLOGICAL-FLUIDS; EXTRACTION; MEMBRANE; WATER; ORGANOPHOSPHORUS; PRECONCENTRATION; DRUGS;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel method for fast determination of nicotine in tobacco and cigarette was established by using high performance liquid chromatography (HPLC) coupled with a partly immersed three phase hollow fiber liquid phase microextraction (PILPME) technique for sample preparation. The model of partly immersed was introduced for the first time. This study has demonstrated that PILPME constituted a real alternative to the other liquid phase microextraction methods. Parameters related to PILPME (organic solvent, pH of donor and acceptor phase, the proportion of hollow fiber in gas and liquid, extraction time, temperature) were optimized experimentally, for preconcentration and extraction of nicotine in tobacco and cigarette samples has shown many advantages over traditional sample preparation technique, which provided a good linear range (0.05-10 mu g/mL) with r(2) = 0.9996, a low detection limit (5 ng/mL, S/N = 3) and a satisfactory relative standard deviation (<8 %). The result showed 3.03 and 3.39 mg/gin tobacco and 1.51, 1.45 and 1.73 ing/g in cigarette, respectively. The recovery was obtained in the range of 95.91-97.95 %.
引用
收藏
页码:3471 / 3475
页数:5
相关论文
共 50 条
  • [1] Rapid determination of semi-VOC using partly-immersed three-phase hollow fiber liquid phase microextraction combined with high performance liquid chromatography
    Lin, Hailu
    Yan, Hong
    Luo, Mingbiao
    Peng, Xuejiao
    Liu, Wei
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [2] Hollow fiber-based liquid phase microextraction combined with high-performance liquid chromatography for the analysis of gabapentin in biological samples
    Ebrahimzadeh, Homeira
    Yamini, Yadollah
    Firozjaei, Hamid Abedi
    Kamarei, Fahimeh
    Tavassoli, Najmeh
    Rouini, Mohammad Reza
    ANALYTICA CHIMICA ACTA, 2010, 665 (02) : 221 - 226
  • [3] Automated preconcentration and analysis of organic compounds by on-line hollow fiber liquid-phase microextraction-high performance liquid chromatography
    Esrafili, Ali
    Yamini, Yadollah
    Ghambarian, Mahnaz
    Ebrahimpour, Behnam
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1262 : 27 - 33
  • [4] Hollow fiber liquid-phase microextraction combined with high performance liquid chromatography for the determination of trace mitiglinide in biological fluids
    Hadi, Hind
    Makahleh, Ahmad
    Saad, Bahruddin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 895 : 131 - 136
  • [5] HOLLOW FIBER LIQUID PHASE MICROEXTRACTION COMBINED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR PRECONCENTRATION AND DETERMINATION OF CABERGOLINE IN BIOLOGICAL SAMPLES
    Piroozi, Forozan
    Ghasemi, Ensieh
    Qomi, Mahnaz
    Rezaee, Raheme
    Hashemian, Farshad
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (05) : 760 - 771
  • [6] Hollow-Fiber Liquid-Phase Microextraction Combined with High-Performance Liquid Chromatography for Analysis of Melamine in Milk Products
    Wang, G. -Y.
    Chen, J.
    Shi, Y. -P.
    ACTA CHROMATOGRAPHICA, 2010, 22 (02) : 307 - 321
  • [7] Three-phase hollow fiber liquid phase microextraction of warfarin from human plasma and its determination by high-performance liquid chromatography
    Hadjmohammadi, Mohammadreza
    Ghambari, Hoda
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 44 - 49
  • [8] Determination of Trace Bisphenol A in Water Using Three-phase Hollow Fiber Liquid-phase Microextraction Coupled with High Performance Liquid Chromatography
    Tan Xiao-Wang
    Song Yan-Xi
    Wei Rui-Ping
    Yi Gu-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (09) : 1409 - 1414
  • [9] Hollow Fiber-Based Liquid Phase Microextraction Combined with High Performance Liquid Chromatography for Determination of Flavonoids in Ginkgo biloba and Urine
    Lu, Huawei
    Wang, Xusheng
    Liu, Xia
    Jiang, Shengxiang
    CHEMIA ANALITYCZNA, 2009, 54 (03): : 309 - 319
  • [10] Determination of trace amounts of organophosphorous pesticides in water using hollow fiber liquid phase microextraction combined with high performance liquid chromatography
    Peng, Xuejiao
    Lin, Hailu
    Luo, Mingbiao
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 6031 - 6034