All-solid-state PVC membrane Ag+-selective electrodes based on diaza-18-crown-6 compounds

被引:29
作者
Isildak, I [1 ]
Yolcu, M
Isildak, O
Demirel, N
Topal, G
Hosgoren, H
机构
[1] Ondokuz Mayis Univ, Fac Sci, Dept Chem, TR-55139 Kurupelit, Turkey
[2] Gaziosmanpasa Univ, Fac Sci, Dept Chem, TR-60200 Tokat, Turkey
[3] Dicle Univ, Fac Sci, Dept Chem, TR-21280 Diyarbakir, Turkey
[4] Dicle Univ, Fac Educ, Dept Chem, TR-21280 Diyarbakir, Turkey
关键词
diaza-crown ethers; all-solid-state; PVC membrane; silver-selective electrodes; FIA;
D O I
10.1007/s00604-003-0072-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two diaza-crown ether compounds were synthesized and evaluated as Ag+-selective carriers in polyvinylchloride (PVC) membrane electrodes of solid-state type. The all-solid-state PVC membrane electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 exhibited a super-Nernstian response (75+/-10 mV per decade) over the concentration range of 1x10(-1) to 7x10(-6) M of Ag+ ion and a detection limit of 3x10(-6) M, at a wide range of pH (pH 4-7). The response time of the electrode was fast (less than similar to10s), and it can be used for three months without any significant deviation in potential. The proposed all-solid-state PVC membrane electrodes revealed high selectivity toward Ag+ ion with respect to alkali, alkaline earth, heavy and transition metal ions. A flow-through cell of all-solid-state PVC membrane Ag+-selective electrode based on N,N-Dibenzyl-dibenzo-diaza-18-crown-6 has also been prepared and applied for flow-injection analysis of Ag+ ion in solution.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 36 条
[1]   RESPONSE CHARACTERISTICS OF CONDUCTIVE POLYMER COMPOSITE SUBSTRATE ALL-SOLID-STATE POLY(VINYL CHLORIDE) MATRIX MEMBRANE ION-SELECTIVE ELECTRODES IN AERATED AND NITROGEN-SATURATED SOLUTIONS [J].
ALEGRET, S ;
FLORIDO, A .
ANALYST, 1991, 116 (05) :473-476
[2]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[3]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[4]   Flow-injection spectrophotometric determination of copper(II) ion at low μg L-1 levels using 4-benzylpiperidinedithiocarbamate [J].
Asan, A ;
Andac, M ;
Isildak, I .
ANALYTICAL SCIENCES, 2001, 17 (09) :1125-1127
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Origin of anion response of solvent polymeric membrane based silver ion-selective electrodes [J].
Bakker, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :20-25
[7]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[8]   ION-SELECTIVE ELECTRODES USING AN IONOPHORE COVALENTLY ATTACHED TO CARBOXYLATED POLY(VINYL CHLORIDE) [J].
DAUNERT, S ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1428-1431
[9]  
DEMIREL N, 1999, THESIS DIYARBAKIR TU
[10]   SELECTIVITY-MODIFYING INFLUENCE OF ANIONIC SITES IN NEUTRAL-CARRIER-BASED MEMBRANE ELECTRODES [J].
EUGSTER, R ;
GEHRIG, PM ;
MORF, WE ;
SPICHIGER, UE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2285-2289