Optimal replacement of residential air conditioning equipment to minimize energy, greenhouse gas emissions, and consumer cost in the US

被引:29
作者
De Kleine, Robert D. [1 ]
Keoleian, Gregory A. [1 ]
Kelly, Jarod C. [1 ]
机构
[1] Univ Michigan, Ctr Sustainable Syst, Sch Nat Resources & Environm, Ann Arbor, MI 48109 USA
关键词
Life cycle optimization; Air conditioning; Replacement policy; EFFICIENCY STANDARDS; LABELING PROGRAM; MALAYSIA; SAVINGS; REFRIGERANTS; APPLIANCES; IMPACTS;
D O I
10.1016/j.enpol.2011.02.065
中图分类号
F [经济];
学科分类号
02 ;
摘要
A life cycle optimization of the replacement of residential central air conditioners (CACs) was conducted in order to identify replacement schedules that minimized three separate objectives: life cycle energy consumption, greenhouse gas (GHG) emissions, and consumer cost. The analysis was conducted for the time period of 1985-2025 for Ann Arbor, MI and San Antonio, TX. Using annual sales-weighted efficiencies of residential CAC equipment, the tradeoff between potential operational savings and the burdens of producing new, more efficient equipment was evaluated. The optimal replacement schedule for each objective was identified for each location and service scenario. In general, minimizing energy consumption required frequent replacement (4-12 replacements), minimizing GHG required fewer replacements (2-5 replacements), and minimizing cost required the fewest replacements (1-3 replacements) over the time horizon. Scenario analysis of different federal efficiency standards, regional standards, and Energy Star purchases were conducted to quantify each policy's impact. For example, a 16 SEER regional standard in Texas was shown to either reduce primary energy consumption 13%, GHGs emissions by 11%, or cost by 6-7% when performing optimal replacement of CACs from 2005 or before. The results also indicate that proper servicing should be a higher priority than optimal replacement to minimize environmental burdens. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3144 / 3153
页数:10
相关论文
共 61 条
[1]  
[Anonymous], 2009, ANN EN OUTL 2009
[2]  
[Anonymous], ANN EN REV 2007
[3]  
[Anonymous], NAT SOL RAD DAT BAS
[4]  
Arthur D., 2002, GLOBAL COMP ANAL HFC
[5]  
*BAUMG HOM INSP IN, 2010, EST REP REPL COSTS
[6]  
BOLE R, 2006, CSS0603
[7]   Comparative life cycle assessment of commonly used refrigerants in commercial refrigeration systems [J].
Bovea, Maria D. ;
Cabello, Ramon ;
Querol, Daria .
INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2007, 12 (05) :299-307
[8]  
*CA PUBL UT COMM, 2008, DAT EN EFF RES
[9]   The climate change implications of manufacturing refrigerants - A calculation of 'production' energy contents of some common refrigerants [J].
Campbell, NJ ;
McCulloch, A .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 1998, 76 (B3) :239-244
[10]  
Creyts J.C., 2007, REDUCING US GREENHOU