Investigation of effects of volume-of-interest mis-registration on accuracy of organ activity estimates obtained with Quantitative Planar processing

被引:0
作者
Song, N. [1 ]
He, B. [1 ]
Frey, E. C. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
D O I
10.1109/NSSMIC.2007.4436787
中图分类号
O59 [应用物理学];
学科分类号
摘要
In targeted radionuclide therapy (TRI), dose estimation is essential for treatment planning and tumor dose response studies. Dose estimates are typically based on whole body conjugate view planar or SPECT imaging of the patient after administration of a planning dose. Quantifying the activity in the organs from these studies is an essential part of dose estimation. The Quantitative Planar (QPlanar) processing method involves both accurate compensation for image degrading factors and correction of overlap from background and organs. It thus provides more accurate activity estimates than traditional planar activity estimation methods. However, alignment between the 3D organ volume of interest (VOIs) used in QPlanar processing and the true organ projections in the planar images is required in this method. The goal of this research was to study the effects of mis-registration of VOIs on the accuracy and precision of organ activity estimates obtained using the QPlanar method. In this work, we modeled the degree of mis-registration that would be expected clinically. Mutual information based image registration was implemented to align realistic simulated 3D SPECT images that can be used to define 3D organ VOIs with 2D planar images. The resulting model of image mis-registration was applied to study the effects of mis-registration on the QPlanar method.
引用
收藏
页码:3105 / 3108
页数:4
相关论文
共 6 条
[1]   Partial volume effect compensation for quantitative brain SPECT imaging [J].
Du, Y ;
Tsui, BMW ;
Frey, EC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) :969-976
[2]  
ESTEBAN MD, 1995, KYBERNETIKA, V31, P337
[3]   Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents [J].
He, Bin ;
Frey, Eric C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (16) :3967-3981
[4]  
PLUIM JPW, 2003, IEEE T MED IMAGING, V10
[5]  
PRESS WH, NUMERICAL RECIPES C
[6]   Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function [J].
Song, X ;
Segars, WP ;
Du, Y ;
Tsui, BMW ;
Frey, EC .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (08) :1791-1804