A glass microfluidic device with two independent electrospray ionization (ESI) emitters has been designed to sequentially generate ions from different solutions for mass analysis. Rapid modulation between the emitters is accomplished by turning on and off the voltage that simultaneously generates the fluid flow rate and ESI potential. The time required to switch between the two electrospray signals is less than 70 ms. Using the second emitter to introduce a reference compound for internal calibration, accurate mass measurements (less than 3 ppm mass error) were obtained with a time-of-flight mass spectrometer.
引用
收藏
页码:1446 / 1451
页数:6
相关论文
共 47 条
[31]   SCALE-UP OF ELECTROSPRAY ATOMIZATION USING LINEAR ARRAYS OF TAYLOR CONES [J].
RULISON, AJ ;
FLAGAN, RC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (03) :683-686
[32]   Accurate mass measurement in nano-electrospray ionization mass spectrometry by alternate switching of high voltage between sample and reference sprayers [J].
Satomi, Y ;
Kudo, Y ;
Sasaki, K ;
Hase, T ;
Takao, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (04) :540-546
[33]   Multiple sprayer system for high-throughput electrospray ionization mass spectrometry [J].
Schneider, BB ;
Douglas, DJ ;
Chen, DDY .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (20) :1982-1990
[34]   Calibrant delivery for mass spectrometry [J].
Schneider, Bradley B. ;
Covey, Thomas R. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (06) :991-996
[35]   Internal standard signal suppression by co-eluting analyte in isotope dilution LC-ESI-MS [J].
Sojo, LE ;
Lum, G ;
Chee, P .
ANALYST, 2003, 128 (01) :51-54
[36]  
Takahashi Y, 2000, RAPID COMMUN MASS SP, V14, P947, DOI 10.1002/(SICI)1097-0231(20000615)14:11<947::AID-RCM970>3.0.CO
[37]  
2-N
[38]   Independent control of ion transmission in a jet disrupter dual-channel ion funnel electrospray ionization MS interface [J].
Tang, KQ ;
Tolmachev, AV ;
Nikolaev, E ;
Zhang, R ;
Belov, ME ;
Udseth, HR ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2002, 74 (20) :5431-5437
[39]   A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides [J].
Ullsten, S ;
Zuberovic, A ;
Wetterhall, M ;
Hardenborg, E ;
Markides, KE ;
Bergquist, J .
ELECTROPHORESIS, 2004, 25 (13) :2090-2099
[40]   ATTOMOLE-SENSITIVITY ELECTROSPRAY SOURCE FOR LARGE-MOLECULE MASS-SPECTROMETRY [J].
VALASKOVIC, GA ;
KELLEHER, NL ;
LITTLE, DP ;
AASERUD, DJ ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1995, 67 (20) :3802-3805