Microfluidic Dual Emitter Electrospray Ionization Source for Accurate Mass Measurements

被引:37
作者
Chambers, Andrew G. [1 ]
Ramsey, J. Michael [1 ]
机构
[1] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
ION-CYCLOTRON RESONANCE; LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; ION/ION REACTIONS; TRANSFER DISSOCIATION; INTERNAL CALIBRATION; REFERENCE SPRAYS; SEPARATE SAMPLE; TRAP; IMPLEMENTATION;
D O I
10.1021/ac202603s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glass microfluidic device with two independent electrospray ionization (ESI) emitters has been designed to sequentially generate ions from different solutions for mass analysis. Rapid modulation between the emitters is accomplished by turning on and off the voltage that simultaneously generates the fluid flow rate and ESI potential. The time required to switch between the two electrospray signals is less than 70 ms. Using the second emitter to introduce a reference compound for internal calibration, accurate mass measurements (less than 3 ppm mass error) were obtained with a time-of-flight mass spectrometer.
引用
收藏
页码:1446 / 1451
页数:6
相关论文
共 47 条
[11]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[12]   Dual-micro-ESI source for precise mass determination on a quadrupole time-of-flight mass spectrometer for genomic and proteomic applications [J].
Flora, JW ;
Null, AP ;
Muddiman, DC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) :538-546
[13]   Microfluidics for multiplexed MS analysis [J].
Foret, Frantisek ;
Kusy, Petr .
ELECTROPHORESIS, 2006, 27 (24) :4877-4887
[14]   NANOELECTROSPRAY EMITTERS: TRENDS AND PERSPECTIVE [J].
Gibson, Graham T. T. ;
Mugo, Samuel M. ;
Oleschuk, Richard D. .
MASS SPECTROMETRY REVIEWS, 2009, 28 (06) :918-936
[15]   A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry [J].
Hannis, JC ;
Muddiman, DC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (10) :876-883
[16]   Novel polyamine coating providing non-covalent deactivation and reversed electroosmotic flow of fused-silica capillaries for capillary electrophoresis [J].
Hardenborg, E ;
Zuberovic, A ;
Ullsten, S ;
Söderberg, L ;
Heldin, E ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1003 (1-2) :217-221
[17]   A study of the performance of microfabricated electroosmotic pump [J].
Hu, J. S. ;
Chao, Christopher Y. H. .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 135 (01) :273-282
[18]   Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry [J].
Jiang, LF ;
Moini, M .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :20-24
[19]   Array of chemically etched fused-silica emitters for improving the sensitivity and quantitation of electrospray ionization mass spectrometry [J].
Kelly, Ryan T. ;
Page, Jason S. ;
Tang, Keqi ;
Smith, Richard D. .
ANALYTICAL CHEMISTRY, 2007, 79 (11) :4192-4198
[20]   A decade of microfluidic analysis coupled with electrospray mass spectrometry: An overview [J].
Koster, Sander ;
Verpoorte, Elisabeth .
LAB ON A CHIP, 2007, 7 (11) :1394-1412