Maximizing Deep Lung Deposition in Healthy and Fibrotic Subjects During Jet Nebulization

被引:15
作者
Samuel, Joshua [1 ]
Smaldone, Gerald C. [1 ]
机构
[1] SUNY Stony Brook, Dept Med, Pulm Crit Care & Sleep Div, Stony Brook, NY 11794 USA
关键词
aerosol; human; inhaled interferon-gamma; nebulizer; scintigraphy; REGIONAL DEPOSITION; INTERFERON-GAMMA; VIBRATING MESH; DELIVERY; VENTILATION; AEROSOLS; SAFETY; MASS;
D O I
10.1089/jamp.2019.1552
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: In volunteers with idiopathic pulmonary fibrosis (IPF), inhaled Interferon-gamma (IFN-gamma) is safe and may improve pulmonary function. However, coughing, associated with upper airway deposition, is often reported. To address this problem, a small-particle, breath-enhanced jet nebulizer (i-NEB Mini; InspiRx, Inc., Somerset, NJ) was developed. Using gamma scintigraphy, this device was tested in healthy individuals and subjects with IPF to determine efficiency and regional deposition in lung and airways. Methods: Four healthy individuals and nine subjects with IPF were enrolled. The nebulizer was filled with 2 mL of saline with (99m) Tc bound to diethylenetriaminepentaacetic acid (DTPA) powered continuously with 3.4 L/min of compressed air. Mass median aerodynamic diameter (MMAD) was measured by cascade impactor. To maximize deposition in alveoli, inspiratory flow was limited by an inspiratory resistance incorporated into the nebulizer, resulting in a deep inspiration similar to 6 seconds. The treatment was run to completion (10 minutes), and each subject underwent deposition imaging. Mass balance and regions of interest determined upper airway (measured by calibrated stomach activity) and regional lung deposition as a percent of pretreatment nebulizer charge. Results: Subjects tolerated the device with no complaints. MMAD (mean [geometric standard deviation]) = 1.04 [1.92] mu m. Lung deposition (mean +/- standard error, % nebulizer charge) in healthy subjects was 26.2% +/- 1.83 and in IPF individuals 23.4% +/- 1.60 (p = 0.414). Upper airway deposition was 1.4% +/- 0.83 and 2.3% +/- 0.48, respectively (p = 0.351), and 20.1% was lost during expiration. Central/Peripheral ratios were consistent in both groups, showing high peripheral deposition (1.32 +/- 0.050, vs. 1.28 +/- 0.046, p = 0.912). Conclusion: The i-NEB Mini jet nebulizer with breath enhancement produced small particles, resulting in minimal upper airway deposition. Using slow and deep breathing, more than half of the emitted dose deposited in the peripheral lung in normal subjects and individuals with IPF. These data indicate that, for future clinical trials, controlled lung doses of small particles, designed to avoid coughing, are possible even in subjects with advanced disease.
引用
收藏
页码:108 / 115
页数:8
相关论文
共 25 条
  • [1] Bajc M, 2009, EUR J NUCL MED MOL I, V36, P1356, DOI 10.1007/s00259-009-1170-5
  • [2] Regional deposition of aerosolized interferon-γ in pulmonary tuberculosis
    Condos, R
    Hull, FP
    Schluger, NW
    Rom, WN
    Smaldone, GC
    [J]. CHEST, 2004, 125 (06) : 2146 - 2155
  • [3] Delivery and Safety of Inhaled Interferon-γ in Idiopathic Pulmonary Fibrosis
    Diaz, Keith T.
    Skaria, Shibu
    Harris, Keith
    Solomita, Mario
    Lau, Stephanie
    Bauer, Kristy
    Smaldone, Gerald C.
    Condos, Rany
    [J]. JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2012, 25 (02) : 79 - 87
  • [4] DEPOSITION OF AMPHOTERICIN-B AEROSOLS IN PULMONARY ASPERGILLOMA
    DIOT, P
    RIVOIRE, B
    LEPAPE, A
    LEMARIE, E
    DIRE, D
    FURET, Y
    BRETEAU, M
    SMALDONE, GC
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1995, 8 (08) : 1263 - 1268
  • [5] RhDNase I aerosol deposition and related factors in cystic fibrosis
    Diot, P
    Palmer, LB
    Smaldone, A
    deCelieGermana, J
    Grimson, R
    Smaldone, GC
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (05) : 1662 - 1668
  • [6] Aerosolized cyclosporine in lung recipients with refractory chronic rejection
    Iacono, AT
    Keenan, RJ
    Duncan, SR
    Smaldone, GC
    Dauber, JH
    Paradis, IL
    Ohori, NP
    Grgurich, WF
    Burckart, GJ
    Zeevi, A
    Delgado, E
    ORiordan, TG
    Zendarsky, MM
    Yousem, SA
    Griffith, BP
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (04) : 1451 - 1455
  • [7] Dose-related reversal of acute lung rejection by aerosolized cyclosporine
    Iacono, AT
    Smaldone, GC
    Keenan, RJ
    Diot, P
    Dauber, JH
    Zeevi, A
    Burckart, GJ
    Griffith, BP
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) : 1690 - 1698
  • [8] Nebulized Mannitol, Particle Distribution, and Cough in Idiopathic Pulmonary Fibrosis
    Kanth, Pooja M.
    Alaienia, Caesar
    Smaldone, Gerald C.
    [J]. RESPIRATORY CARE, 2018, 63 (11) : 1407 - 1412
  • [9] QUANTITATIVE ASSAYS OF PHARMACOLOGIC AEROSOLS USED IN STUDYING ASTHMA
    MESSINA, MS
    PERRY, R
    SILVERBERG, M
    KAPLAN, AP
    SMALDONE, GC
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1985, 76 (04) : 605 - 609
  • [10] EVALUATION OF QUANTITATIVE AEROSOL TECHNIQUES FOR USE IN BRONCHOPROVOCATION STUDIES
    MESSINA, MS
    SMALDONE, GC
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1985, 75 (02) : 252 - 257