Comparative study on axial load capacity of PFCC column-beam joints with two different connection configurations

被引:0
|
作者
Fang, Yuan [1 ]
Yu, Feng [1 ]
Qian, Yuandi [1 ,2 ]
Bai, Rui [3 ]
Song, Zekang [1 ]
Zhu, Defeng [1 ]
Li, Dongang [1 ]
机构
[1] Anhui Univ Technol, Dept Civil Engn & Architecture, Maanshan 243032, Anhui, Peoples R China
[2] China MCC17 Grp Co Ltd, Technol Ctr, Maanshan 243000, Anhui, Peoples R China
[3] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hung Hom, Kowloon, Hong Kong 999077, Peoples R China
基金
中国国家自然科学基金;
关键词
beam-column joint; failure mode; load capacity; PVC-FRP confined concrete; unified formula; CONFINED CONCRETE COLUMNS; STEEL TUBULAR COLUMN; SEISMIC BEHAVIOR; CFST COLUMNS; COMPRESSIVE BEHAVIOR; PERFORMANCE; STRENGTH; SYSTEM; TESTS; MODEL;
D O I
10.12989/acc.2022.14.4.279
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, seventeen PVC-FRP confined Concrete (PFCC) column-beam joints including eight PFCC column -enlarged ring beam (ERB) joints and nine PFCC column-beam joints strengthened with Core Steel Tube (CST) are designed and tested. The failure modes, ultimate load capacity, deformation capacity of two different types of joints is compared and analyzed. The test results demonstrate that the failure processes of two different types of joints are basically similar, experiencing the elastic, crack development, yield and failure phases. Comparatively, the PFCC column-ERB joints enter the yield phase relatively earlier than the joints strengthened with CST. Both of the connection configurations can effectively constraint the concrete at the joints and significantly improve load capacity, showing their respective advantages. From the point of view of improving the connection efficiency of the joints, increasing ring beam width has the most obvious effect on the PFCC column-ERB joints, while reasonably reducing the height of joint has the greatest influence on the joints strengthened with CST. The axial equivalent ultimate strains of these two different types of joints are much higher than the ultimate compressive strains of ordinary concrete, indicating that both of the connection configurations can remarkably enhance the deformation capacity of the joints. By comparison, the deformation resistances of the PFCC column-ERB joints are greater than those of the joints strengthened with CST. In addition, taking into account the scale effect, a comprehensive influence coefficient of the joints is introduced, and a unified formula for estimating the axial load capacities of the two different joints is proposed based on a modified superposition approach and validates the test data of this paper and other references with good agreement.
引用
收藏
页码:279 / 289
页数:11
相关论文
共 40 条
  • [21] An experimental study of composite effect on the behaviour of beam-column joints subjected to impact load
    Chen, K.
    Tan, K. H.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 905 - 912
  • [22] Experimental seismic study of precast hybrid SFC/RC beam-column connections with different connection details
    Zhang, Jianxin
    Ding, Chuanlin
    Rong, Xian
    Yang, Hongwei
    Wang, Ke
    Zhang, Biao
    ENGINEERING STRUCTURES, 2020, 208
  • [23] Experimental Study on Bearing Capacity of Polyvinyl Chloride Carbon Fiber-Reinforced Polymer-Confined Reinforced Concrete Column with Ring Beam Joint under Axial Load
    Yu, Feng
    Wang, Shisi
    Fang, Yuan
    Zhu, Defeng
    Kong, Zhengyi
    ACI STRUCTURAL JOURNAL, 2020, 117 (05) : 203 - 216
  • [24] Comparative study on the seismic behavior of precast concrete-encased CFST column to precast and cast-in-place beam joints
    Zhu, Yazhi
    Wang, Wei
    Lin, Ronghui
    JOURNAL OF BUILDING ENGINEERING, 2025, 104
  • [25] Experimental study on internal precast beam-column ultra-high-performance concrete connection and shear capacity of its joint
    Ma, Fudong
    Deng, Mingke
    Yang, Yong
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [26] Experimental and numerical study of reinforced concrete interior wide beam-column joints subjected to lateral load
    Mirzabagheri, Sara
    Tasnimi, Abbas Ali
    Issa, Fadwa
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2018, 45 (11) : 947 - 957
  • [27] A comparative study of two different configurations for exothermic-endothermic heat exchanger reactor
    Bayat, M.
    Rahimpour, M. R.
    Taheri, M.
    Pashaei, M.
    Sharifzadeh, S.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2012, 52 : 63 - 73
  • [28] A comparative numerical study on the innovative I-beam to thin-walled hybrid fabricated column connection
    Sadeghi, Seyed Nima
    Heidarpour, Amin
    Zhao, Xiao-Ling
    Al-Mahaidi, Riadh
    THIN-WALLED STRUCTURES, 2018, 127 : 235 - 258
  • [29] Experimental Study on Seismic Performance of Precast Pretensioned Prestressed Concrete Beam-Column Interior Joints Using UHPC for Connection
    Xiong, Xueyu
    Xie, Yifan
    Yao, Gangfeng
    Liu, Ju
    Yan, Laizhang
    He, Liang
    MATERIALS, 2022, 15 (16)
  • [30] Experimental study on seismic behavior of angle connection joints for concrete-filled square steel tubular column to steel beam
    Xu M.
    Wu Z.
    Zhang L.
    Liang S.
    Zhang, Lingxin (jzgcsub@163.com), 1600, Science Press (38): : 384 - 393