Rapid deployment technology versus conventional sutured bioprostheses in aortic valve replacement

被引:11
作者
Salmasi, Mohammad Yousuf [1 ]
Ramaraju, Sruthi [1 ,2 ]
Haq, Iqraa [1 ]
B. Mohamed, Ryan A. [2 ]
Khan, Taimoor [2 ]
Oezalp, Faruk [2 ]
Asimakopoulos, George [2 ]
Raja, Shahzad G. [2 ]
机构
[1] Imperial Coll London, Dept Surg, London, England
[2] Royal Brompton & Harefield Trust, Dept Cardiac Surg, London, England
关键词
aortic valve replacement; rapid deployment valves; sutureless valves; MINIMALLY INVASIVE APPROACH; PACEMAKER IMPLANTATION; STENTED BIOPROSTHESIS; FULL STERNOTOMY; OUTCOMES; SURGERY; MULTICENTER; PROSTHESIS; MANAGEMENT; STENTLESS;
D O I
10.1111/jocs.16223
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Despite the benefits of rapid deployment aortic valve prostheses (RDAVR), conventional sutured valves (cAVR) are more commonly used in the treatment for aortic stenosis. Given the paucity of randomized studies, this study aimed to synthesize available data to compare both treatment options. Methods A systematic search of Pubmed, OVID, and MEDLINE was conducted to retrieve comparative studies for RDAVR versus cAVR in the treatment of aortic stenosis. Out of 1773 returned titles, 35 papers were used in the final analysis, including 1 randomized study, 1 registry study, 6 propensity-matched studies, and 28 observational studies, incorporating a total of 10,381 participants (RDAVR n = 3686; cAVR n = 6310). Results Random-effects meta-analysis found no difference between the two treatment groups in terms of operative mortality, stroke, or bleeding (p > .05). The RDAVR group had reduced cardiopulmonary bypass (standardized mean difference [SMD]: -1.28, 95% confidence interval [CI]: [-1.35, -1.20], p < .001) and cross-clamp times (SMD: -1.05, 95% CI: [-1.12, -0.98], p < .001). Length of stay in the intensive care unit was also shorter in the RDAVR group (SMD: -0.385, 95% CI: [-0.679, -0.092], p = .010). The risk of pacemaker insertion was higher for RDAVR (odds ratio [OR]: 2.41, 95% CI: [1.92, 3.01], p < .001) as was the risk of paravalvular leak (PVL) at midterm follow-up (OR: 2.52, 95% CI: [1.32, 4.79], p = .005). Effective orifice area and transvalvular gradient were more favorable in RDAVR patients (p > .05). Conclusions Despite the benefits of RDAVR in terms of reduced operative time and enhanced recovery, the risk of pacemaker insertion and midterm PVL remains a significant cause for concern.
引用
收藏
页码:640 / 655
页数:16
相关论文
共 59 条
[51]   Thrombocytopaenia after aortic valve replacement with stented, stentless and sutureless bioprostheses [J].
Stanger, Olaf ;
Grabherr, Michael ;
Gahl, Brigitta ;
Longnus, Sarah ;
Meinitzer, Andreas ;
Fiedler, Martin ;
Tevaearai, Hendrik ;
Carrel, Thierry .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (02) :340-346
[52]   Thrombocytopenia after implantation of the Perceval S aortic bioprosthesis [J].
Stegmeier, Philipp ;
Schloemicher, Markus ;
Stiegler, Hugo ;
Strauch, Justus T. ;
Bechtel, J. F. Matthias .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 160 (01) :61-+
[53]   Direct and adjusted indirect comparisons of perioperative mortality after sutureless or rapid-deployment aortic valve replacement versus transcatheter aortic valve implantation [J].
Takagi, Hisato ;
Ando, Tomo ;
Umemoto, Takuya .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 228 :327-334
[54]   A Meta-Analysis of Sutureless or Rapid-Deployment Aortic Valve Replacement [J].
Takagi, Hisato ;
Umemoto, Takuya .
THORACIC AND CARDIOVASCULAR SURGEON, 2016, 64 (05) :400-409
[55]  
Thitivaraporn Puwadon, 2018, Korean J Thorac Cardiovasc Surg, V51, P172, DOI [10.5090/kjtcs.2018.51.3.172, 10.5090/kjtcs.2018.51.3.172]
[56]   Pacemaker After Transcatheter Aortic Valve Replacement Unexpected, But Not Infrequent Outcome [J].
Tracy, Cynthia M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (02) :141-143
[57]   Sutureless aortic valve replacement in high risk patients neutralizes expected worse hospital outcome: A clinical and economic analysis [J].
Villa, Emmanuel ;
Dalla Tomba, Margherita ;
Messina, Antonio ;
Trenta, Andrea ;
Brunelli, Federico ;
Cirillo, Marco ;
Mhagna, Zean ;
Chiariello, Giovanni Alfonso ;
Troise, Giovanni .
CARDIOLOGY JOURNAL, 2019, 26 (01) :56-65
[58]   Sutureless Prostheses and Less Invasive Aortic Valve Replacement: Just an Issue of Clamping Time? [J].
Vola, Marco ;
Campisi, Salvatore ;
Gerbay, Antoine ;
Fuzellier, Jean-Francois ;
Ayari, Iness ;
Favre, Jean-Pierre ;
Faure, Michael ;
Morel, Jerome ;
Anselmi, Amedeo .
ANNALS OF THORACIC SURGERY, 2015, 99 (05) :1518-1523
[59]  
Wahlers TCW, 2018, INNOVATIONS, V13, P177, DOI 10.1097/IMI.0000000000000509