Aptamer-Based Lateral Flow Assays: Current Trends in Clinical Diagnostic Rapid Tests

被引:42
|
作者
Majdinasab, Marjan [1 ]
Badea, Mihaela [2 ]
Marty, Jean Louis [3 ]
机构
[1] Shiraz Univ, Sch Agr, Dept Food Sci & Technol, Shiraz 7144165186, Iran
[2] Transilvania Univ Brasov, Fac Med, Nicolae Balcescu St 56, Brasov 500019, Romania
[3] Univ Perpignan Via Domitia, 52 Ave Paul Alduy, F-66860 Perpignan, France
关键词
aptamer; lateral flow assay; clinical; biomarker; rapid test; IMMUNOCHROMATOGRAPHIC ASSAY; ELECTROCHEMICAL APTASENSOR; GOLD NANOPARTICLES; BIOSENSOR; IMMUNOASSAY; BIOMARKERS; MELAMINE; MILK;
D O I
10.3390/ph15010090
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The lateral flow assay (LFA) is an extensively used paper-based platform for the rapid and on-site detection of different analytes. The method is user-friendly with no need for sophisticated operation and only includes adding sample. Generally, antibodies are employed as the biorecognition elements in the LFA. However, antibodies possess several disadvantages including poor stability, high batch-to-batch variation, long development time, high price and need for ethical approval and cold chain. Because of these limitations, aptamers screened by an in vitro process can be a good alternative to antibodies as biorecognition molecules in the LFA. In recent years, aptamer-based LFAs have been investigated for the detection of different analytes in point-of-care diagnostics. In this review, we summarize the applications of aptamer technology in LFAs in clinical diagnostic rapid tests for the detection of biomarkers, microbial analytes, hormones and antibiotics. Performance, advantages and drawbacks of the developed assays are also discussed.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Aptamer-based lateral flow assays
    Schueling, Torsten
    Eilers, Alina
    Scheper, Thomas
    Walter, Johanna
    AIMS BIOENGINEERING, 2018, 5 (02): : 78 - 102
  • [2] Aptamer-Based Lateral Flow Biosensor for Rapid Detection of Salivary Cortisol
    Dalirirad, Shima
    Han, Daewoo
    Steckl, Andrew J.
    ACS OMEGA, 2020, 5 (51): : 32890 - 32898
  • [3] Emerging techniques employed in aptamer-based diagnostic tests
    Yoshida, Wataru
    Abe, Koichi
    Ikebukuro, Kazunori
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2014, 14 (02) : 143 - 151
  • [4] Recent developments of aptamer-based lateral flow assays for point-of-care (POC) diagnostics
    Jaisankar, Abinaya
    Krishnan, Sasirekha
    Rangasamy, Loganathan
    ANALYTICAL BIOCHEMISTRY, 2022, 655
  • [5] Assays for aptamer-based platforms
    Citartan, Marimuthu
    Gopinath, Subash C. B.
    Tominaga, Junji
    Tan, Soo-Choon
    Tang, Thean-Hock
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 1 - 11
  • [6] Aptamer-Based Lateral Flow Test Strip for Rapid Detection of Zearalenone in Corn Samples
    Wu, Shijia
    Liu, Lihong
    Duan, Nuo
    Li, Qian
    Zhou, You
    Wang, Zhouping
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (08) : 1949 - 1954
  • [7] Design an aptamer-based sensitive lateral flow biosensor for rapid determination of isocarbophos pesticide in foods
    Liu, Bangyan
    Tang, Yue
    Yang, Yuxia
    Wu, Yuangen
    FOOD CONTROL, 2021, 129
  • [8] Aptamer-based lateral flow assay on-site biosensors
    Huang, Lei
    Tian, Shulin
    Zhao, Wenhao
    Liu, Ke
    Ma, Xing
    Guo, Jinhong
    BIOSENSORS & BIOELECTRONICS, 2021, 186
  • [9] Aptamer lateral flow assays for rapid and sensitive detection of cholera toxin
    Frohnmeyer, Esther
    Tuschel, Nadine
    Sitz, Tobias
    Hermann, Cornelia
    Dahl, Gregor T.
    Schulz, Florian
    Baeumner, Antje J.
    Fischer, Markus
    ANALYST, 2019, 144 (05) : 1840 - 1849
  • [10] Simultaneous and Rapid Detection of Glucose and Insulin: Coupling Enzymatic and Aptamer-Based Assays
    Nandhakumar, Ponnusamy
    Djassemi, Omeed
    Raucci, Ada
    Chang, An-Yi
    Cheung, Christopher
    Dugas, Yuma
    Silberman, Julia
    Morales-Fermin, Sofia
    Sandhu, Samar S.
    Reynoso, Maria
    Saha, Tamoghna
    Cinti, Stefano
    Wang, Joseph
    ANALYTICAL CHEMISTRY, 2024, 96 (47) : 18806 - 18814