Electrochemical Behavior of Oxygen-Terminated Boron-Doped Diamond Electrodes in Different Electrolyte Media

被引:0
作者
Benesova, Lenka [1 ]
Hammer, Petr [1 ]
Vosahlova, Jana [1 ]
Zavazalova, Jaroslava [1 ]
Peckovÿ, Karolina [1 ]
机构
[1] Charles Univ Prague, Fac Sci, Univ Res Ctr Supramol Chem, Dept Analyt Chem, CZ-12843 Prague 2, Czech Republic
来源
XXXIV. MODERNI ELEKTROCHEMICKE METODY | 2014年
关键词
Boron-doped diamond; Electrolyte; Boron concetration; Voltammetry; FILM ELECTRODES; IN-SITU;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Electrochemical behavior of oxygen-terminated BDD electrodes was investigated using cyclic voltammetry in different aqueous and mixed aqueous-organic media. The influence of boron concentration, pH and composition of the electrolyte on the width of the potential window was investigated. It is inversely dependent on the doping level. Further, addition of methanol causes significant narrowing of the potential window at the anodic side, contrary to addition of acetonitrile. These results demonstrate that for electroanalytical purposes, proper choice of BDD electrode and supporting electrolyte is important especially when considering detection of analytes undergoing electro oxidation or reduction at high anodic or cathodic potentials.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 12 条
  • [1] Barek J., 2007, ELECTROANALYSIS, V2003
  • [2] Hydroxyl radicals electrochemically generated in situ on a boron-doped diamond electrode
    Enache, Teodor Adrian
    Chiorcea-Paquim, Ana-Maria
    Fatibello-Filho, Orlando
    Oliveira-Brett, Ana Maria
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (07) : 1342 - 1345
  • [3] Fujishima, 2005, DIAMOND ELECTROCHEMI
  • [4] Examination of the Factors Affecting the Electrochemical Performance of Oxygen-Terminated Polycrystalline Boron-Doped Diamond Electrodes
    Hutton, Laura A.
    Iacobini, James G.
    Bitziou, Eleni
    Channon, Robert B.
    Newton, Mark E.
    Macpherson, Julie V.
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (15) : 7230 - 7240
  • [5] Interaction of hydrogen with boron, phosphorus, and sulfur in diamond
    Lombardi, EB
    Mainwood, A
    Osuch, K
    [J]. PHYSICAL REVIEW B, 2004, 70 (20) : 205201 - 1
  • [6] Thin-Layer and Wall-Jet Arrangement of Amperometric Detector with Boron-Doped Diamond Electrode: Comparison of Amperometric Determination of Aminobiphenyls in HPLC-ED
    Maixnerova, Lucie
    Barek, Jiri
    Peckova, Karolina
    [J]. ELECTROANALYSIS, 2012, 24 (03) : 649 - 658
  • [7] The influence of boron content on electroanalytical detection of nitrate using BDD electrodes
    Matsushima, J. T.
    Silva, W. M.
    Azevedo, A. F.
    Baldan, M. R.
    Ferreira, N. G.
    [J]. APPLIED SURFACE SCIENCE, 2009, 256 (03) : 757 - 762
  • [8] Musilová J, 2009, CHEM LISTY, V103, P469
  • [9] Boron-Doped Diamond Film Electrodes-New Tool for Voltammetric Determination of Organic Substances
    Peckova, Karolina
    Musilova, Jana
    Barek, Jiri
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 39 (03) : 148 - 172
  • [10] On the activation and physical degradation of boron-doped diamond surfaces brought on by cathodic pretreatments
    Salazar-Banda, Giancarlo R.
    de Carvalho, Adriana E.
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Avaca, Luis A.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (10) : 1817 - 1827