Age variations in intraocular pressure in a cohort of healthy Austrian school children

被引:12
作者
Dusek, W. A. [1 ]
Pierscionek, B. K. [1 ]
McClelland, J. F. [1 ]
机构
[1] Univ Ulster, Sch Biomed Sci, Vis Sci Res Grp, Coleraine BT52 1SA, Londonderry, North Ireland
关键词
intraocular pressure; children; tonometry; Icare; GOLDMANN APPLANATION TONOMETER; ICARE(R) REBOUND TONOMETER; CENTRAL CORNEAL THICKNESS; PEDIATRIC POPULATION; ACCOMMODATION; AMPLITUDE;
D O I
10.1038/eye.2012.54
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose Limited data exist detailing the normal range of intraocular pressure (IOP) for healthy school age children. This study aims to describe the mean and normal range of IOP measurements that may be expected using the Icare rebound tonometer and to examine associations between visual function measures and IOP. Methods Six measurements of IOP from each eye were obtained from 211 normal children aged 6-15 years (79 females and 132 males) using the Icare tonometer. Other measures of visual function obtained included: visual acuity, non-cycloplegic retinoscopy, amplitude of accommodation, accommodative facility, and accommodative response. Results Statistical analysis (Mann-Whitney U test) demonstrated that the male subjects were more likely to have higher IOP measurements than the female subjects (mean IOP males 15.02 mm Hg (SD 2.19), mean IOP females 14.44 (SD 2.01) P = 0.041). Analysis (Spearman's rho) showed a statistically significant association between age and IOP (right eye) in males (P < 0.001) but no association for females (P = 0.459). Using Spearman's rank analysis, statistically significant associations were found between IOP and amplitude of accommodation in males, for the whole data set (P = 0.09) and for data up to age 11 (P < 0.001). For females no statistically significant association was found for the whole data set (P = 0.253) or for data up to age 11 (P = 0.08). IOP was not significantly associated with visual acuity, refractive error, accommodative facility, or accommodative response. Conclusion This study provides useful normative IOP data using the Icare tonometer for a European cohort of school age children. Eye (2012) 26, 841-845; doi:10.1038/eye.2012.54; published online 23 March 2012
引用
收藏
页码:841 / 845
页数:5
相关论文
共 30 条
  • [1] Comparison of the ICare® rebound tonometer with the Goldmann applanation tonometer by experienced and inexperienced tonometrists
    Abraham, L. M.
    Epasinghe, N. C. R.
    Selva, D.
    Casson, R.
    [J]. EYE, 2008, 22 (04) : 503 - 506
  • [2] Evaluation of the ICare Rebound Tonometer as a Home Intraocular Pressure Monitoring Device
    Asrani, Sanjay
    Chatterjee, Ashmita
    Wallace, David K.
    Santiago-Turla, Cecilia
    Stinnett, Sandra
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (02) : 74 - 79
  • [3] PRACTICAL APPLICATION OF ZEISS-POLATEST
    BAUMANN, HE
    [J]. OPHTHALMOLOGICA, 1969, 158 (5-6) : 612 - &
  • [4] Bhan A, 2002, INVEST OPHTH VIS SCI, V43, P1389
  • [5] Glaucoma in children: Are we making progress?
    Biglan, AW
    [J]. JOURNAL OF AAPOS, 2006, 10 (01): : 7 - 21
  • [6] Bradfield YS, 2011, ARCH OPHTHALMOL-CHIC, V129, P1132, DOI 10.1001/archophthalmol.2011.225
  • [7] Brautaset R L, 2001, Strabismus, V9, P165, DOI 10.1076/stra.9.3.165.6764
  • [8] Comparison of three methods of intraocular pressure measurement and their relation to central corneal thickness
    Carbonaro, F.
    Andrew, T.
    Mackey, D. A.
    Spector, T. D.
    Hammond, C. J.
    [J]. EYE, 2010, 24 (07) : 1165 - 1170
  • [9] Measurement of intraocular pressure in children in the UK
    Chan, W. H.
    Lloyd, I. C.
    Ashworth, J. L.
    May, K.
    Bhojwani, D.
    Biswas, S.
    [J]. EYE, 2011, 25 (01) : 119 - 120
  • [10] Chen AH, 2000, OPHTHAL PHYSL OPT, V20, P185