AN ADAPTIVE STRUCTURE TOPOLOGY OPTIMIZATION APPROACH APPLIED TO VERTEBRAL BONE ARCHITECTURE

被引:0
|
作者
DiCarlo, Anthony A. [1 ]
Gallagher, John A. [1 ]
机构
[1] Merrimack Coll, Dept Mech Engn, N Andover, MA 01845 USA
来源
PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, 2017, VOL 2 | 2018年
关键词
BODY COMPRESSIVE STRENGTH; TRABECULAR BONE; MINERAL DENSITY; IN-VITRO; OSTEOPOROSIS; EPIDEMIOLOGY; DENSITOMETRY; PREDICTION; PLATES;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Bone is a highly adaptive biological structure. Following Wolff's law, bone realigns and grows to adapt to its mechanical environment. This leads to structural heterogeneity of trabecular bone and orthotropic symmetry of the elastic properties. Determining the bone alignment and material properties for living patients is difficult and involves implantation of force and displacement sensors on the bone to determine the compliance and stiffness properties. Micro computed tomography along with finite element modeling have been limited to the vertebrae of donor cadavers to evaluate trabecular architecture, material properties, and density. Here, an adaptive structure topology optimization algorithm is presented and used to predict trabecular architecture. The algorithm predicts the optimal structure by minimizing the global compliance. The lumbar 1 (L1) vertebra is used as an example. Loads common to L 1 vertebrae are applied and bone volume fraction measurements that can be taken easily from living patients through bone mineral density scans are used as the only inputs. The mathematical model is an adaptation of "99 Line Topology Optimization Code Written in Matlab" developed by Sigmund (2001). Bone is locally assumed to be isotropic with an elastic modulus of 13 GPa and the Poisson ratio of 0.3 applied to each element. The resulting structural heterogeneity results in global orthotropic relations. The model uses bone volume fraction and the loading orientation as inputs and gives the corresponding ideal bone structure geometry as an output. The trabecular structure can be predicted solely from the results of a bone mineral density scan. Finite element analysis of the optimized structure is then conducted and the global material properties are determined. While this model is for two-dimensional examples representing planes within the vertebral bone, it is extended to three-dimensional modeling to develop the cortical bone geometry and define the total volume. Matlab is then used to run the topology optimization simulation. The ideal structure is defined by optimizing for a prescribed displacement field of the system following the implementation of a gradient descent optimization method. The results are compared to published values from a combined experimental and numerical procedure. The procedure on sectioned vertebrae reported average ratios between elastic moduli of E1/E2 = 5.2, E1/E3 = 8.8, and E2/E3 = 1.4. Results between the models and the previously published data yield similar transversely isotropic symmetry in the elastic moduli of trabecular bone. However, the elastic moduli ratios are not quite in agreement. Improving the accuracy of the boundary conditions and loading of the finite element model may improve the correlation between the optimization models and published data.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Measurement of intraspecimen variations in vertebral cancellous bone architecture
    Kothari, M
    Keaveny, TM
    Lin, JC
    Newitt, DC
    Majumdar, S
    BONE, 1999, 25 (02) : 245 - 250
  • [2] Variation of canine vertebral bone architecture in computed tomography
    Cheon, Byunggyu
    Park, Seungjo
    Lee, Sang-kwon
    Park, Jun-Gyu
    Cho, Kyoung-Oh
    Choi, Jihye
    JOURNAL OF VETERINARY SCIENCE, 2018, 19 (01) : 145 - 150
  • [3] Structure and function of vertebral trabecular bone
    Smit, TH
    Odgaard, A
    Schneider, E
    SPINE, 1997, 22 (24) : 2823 - 2833
  • [4] Adaptive isogeometric topology optimization using PHT splines
    Gupta, Abhinav
    Mamindlapelly, Bhagath
    Karuthedath, Philip Luke
    Chowdhury, Rajib
    Chakrabarti, Anupam
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2022, 395
  • [5] Trabecular bone structure analysis of the spine using clinical MDCT: can it predict vertebral bone strength?
    Baum, Thomas
    Graebeldinger, Martin
    Raeth, Christoph
    Garcia, Eduardo Grande
    Burgkart, Rainer
    Patsch, Janina M.
    Rummeny, Ernst J.
    Link, Thomas M.
    Bauer, Jan S.
    JOURNAL OF BONE AND MINERAL METABOLISM, 2014, 32 (01) : 56 - 64
  • [6] Romosozumab Enhances Vertebral Bone Structure in Women With Low Bone Density
    Poole, Kenneth E. S.
    Treece, Graham M.
    Pearson, Rose A.
    Gee, Andrew H.
    Bolognese, Michael A.
    Brown, Jacques P.
    Goemaere, Stefan
    Grauer, Andreas
    Hanley, David A.
    Mautalen, Carlos
    Recknor, Chris
    Yang, Yu-Ching
    Rojeski, Maria
    Libanati, Cesar
    Whitmarsh, Tristan
    JOURNAL OF BONE AND MINERAL RESEARCH, 2022, 37 (02) : 256 - 264
  • [7] Intervertebral disc disorganisation and its relationship to age adjusted vertebral body morphometry and vertebral bone architecture
    Fazzalari, NL
    Manthey, B
    Parkinson, IH
    ANATOMICAL RECORD, 2001, 262 (03): : 331 - 339
  • [8] Relation of Vertebral Deformities to Bone Density, Structure, and Strength
    Melton, L. Joseph, III
    Riggs, B. Lawrence
    Keaveny, Tony M.
    Achenbach, Sara J.
    Kopperdahl, David
    Camp, Jon J.
    Rouleau, Peggy A.
    Amin, Shreyasee
    Atkinson, Elizabeth J.
    Robb, Richard A.
    Therneau, Terry M.
    Khosla, Sundeep
    JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (09) : 1922 - 1930
  • [9] Bone mineral density and spongiosa architecture in correlation to vertebral body insufficiency fractures
    Andresen, R
    Radmer, S
    Banzer, D
    ACTA RADIOLOGICA, 1998, 39 (05) : 538 - 542
  • [10] Drilling Speed and Bone Temperature of a Robot-assisted Ultrasonic Osteotome Applied to Vertebral Cancellous Bone
    Lang, Zhao
    Wang, Qilong
    Wu, Xinfeng
    Liu, Yajun
    Fan, Mingxing
    Shi, Zhan
    Tian, Wei
    SPINE, 2021, 46 (14) : E760 - E768